An uncertainty analysis of the NIST airspeed standards

被引:0
|
作者
Yeh, T. T. [1 ]
Hall, J. M. [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
来源
FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT ASME/JSME FLUIDS ENGINEERING SUMMER CONFERENCE, VOL 2, PTS A AND B | 2007年
关键词
airspeed standards; windspeed; airspeed calibration; uncertainty analysis;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The National Institute of Standards and Technology (NIST) provides calibration services for airspeed instrumentation. This document describes the uncertainty of the NIST airspeed standards. An extensive component analysis of the system was performed. The standard for airspeed measurement at NIST is a fiber optic Laser Doppler Anemometer (LDA), which is calibrated with known velocities produced by a rotating disk. Airspeed calibrations are performed in a wind tunnel which has a test cross section of 1.5 m by 2.1 m over a range of speeds from 0.15 m/s to 40 m/s. Over this range, the airspeed uncertainty is found to be a function of airspeed and the expanded uncertainty at 95% confidence level, i.e. k=2, in m/s can be expressed by the root-sum-square of 0.0048 V and 0.0068 m/s, where V is airspeed in m/s. This gives a maximum uncertainty of 4.6% at the lowest airspeed of 0.15 m/s and a minimum uncertainty of 0.48% at the highest speed of 40 m/s.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 50 条
  • [1] Uncertainty propagation for NIST visible spectral standards
    Gardner, JL
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2004, 109 (03) : 305 - 318
  • [2] Re-analysis of the uncertainty of the 0.895 μm diameter (NIST SRM® 1690) and the 0.269 μm diameter (NIST SRM® 1691) sphere standards
    Mulholland, GW
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2005, 110 (01) : 27 - 30
  • [3] Uncertainty analysis for the NIST 0:45 reflectometer
    Early, Edward A.
    Nadal, Maria E.
    COLOR RESEARCH AND APPLICATION, 2008, 33 (02): : 100 - 107
  • [4] NIST and standards for calorimetry
    Archer, DG
    Kirklin, DR
    THERMOCHIMICA ACTA, 2000, 347 (1-2) : 21 - 30
  • [5] Uncertainty Analysis for Noise-Parameter Measurements at NIST
    Randa, James
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) : 1146 - 1151
  • [6] NIST security standards - Respond
    Ross, Ron
    COMPUTER, 2007, 40 (10) : 6 - 7
  • [7] Primary frequency standards at NIST
    Sullivan, DB
    2001 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2001, : 849 - 852
  • [8] NIST and the changing world of standards
    Lyons, John W.
    ASTM Standardization News, 1993, 21 (01):
  • [9] NIST Spectroscopic Measurement Standards
    Cole, Kenneth D.
    DeRose, Paul
    He, Hua-Jun
    Stein, Erica V.
    Lang, Brian
    Schiel, John
    Urbas, Aaron
    Solis, Evelyn
    Choquette, Steve
    BIOPHARM INTERNATIONAL, 2018, 31 (05) : 22 - 34
  • [10] NIST FUNDS STANDARDS EDUCATION
    不详
    MECHANICAL ENGINEERING, 2015, 137 (12) : 27 - 27