Extraction of Input Function from 18FDG-PET Images

被引:0
作者
Mabrouk, Rostom [2 ]
Croteau, Etienne [1 ]
Bentabet, Layachi [4 ]
Sarrhini, Otman [1 ]
Beaudoin, Jean-Francois [1 ]
Dubeau, Francois [3 ]
Bentourkia, M'hamed [1 ]
机构
[1] Univ Sherbrooke, Fac Med & Sci Sante, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, Fac Sci, Dept Informat, Sherbrooke, PQ, Canada
[3] Univ Sherbrooke, Fac Sci, Dept Math, Sherbrooke, PQ, Canada
[4] Bishops Univ, Dept Comp Sci, Lennoxville, PQ, Canada
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
TIME-ACTIVITY CURVE; POSITRON EMISSION TOMOGRAPHY; ARTERIAL-BLOOD; PET; DISPERSION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Serial arterial blood sampling is required to determine the input function (IF) in quantitative estimation of physiological parameters in dynamic positron emission tomography (PET) studies. However, blood sampling in PET studies is problematic, invasive and risky. Several approaches have been proposed to extract IF from images among them factor analysis of dynamic structures (FADS) and simultaneous estimation of IF and physiological parameters. FADS, needs a dimension reduction of data, intermediate steps as oblique analysis, and simultaneous estimation needs to fit exponential parameters. In this paper, we introduced a new and simple approach based on the decomposition of image pixel intensity in blood and tissue using Bayesian predictions. The method used an a priori knowledge of the probable distribution of blood and tissue in the images. Weights were then calculated accounting for concentrations of the radiotracer in blood and tissue and their contribution in each image pixel. The calculated images provided more accurate blood and tissue components free from spillover from each other. The results show that this new approach generated tissue glucose metabolic values comparable to those obtained with manual blood sampling (p = 4.13), while these values were significantly different from those calculated with region of interest drawn on the blood pool (p = 2.6.10(-4)). The new approach is fast and simple in implementation and directly generates predefined components with homogeneous intensities without the recourse to fitting parameters or non-negativity constraints. The method can also be used to generate images of desired components.
引用
收藏
页码:3571 / 3575
页数:5
相关论文
共 26 条
  • [1] COMPLICATIONS OF PERCUTANEOUS RADIAL-ARTERY CANNULATION - OBJECTIVE PROSPECTIVE STUDY IN MAN
    BEDFORD, RF
    WOLLMAN, H
    [J]. ANESTHESIOLOGY, 1973, 38 (03) : 228 - 236
  • [2] A standardized blood sampling scheme in quantitative FDG-PET studies
    Bentourkia, M
    Bol, A
    Ivanoiu, A
    Michel, C
    Coppens, A
    Sibomana, M
    Cosnard, G
    De Volder, AG
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (05) : 379 - 384
  • [3] Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET
    Boellaard, R
    van Lingen, A
    van Balen, SCM
    Hoving, BG
    Lammertsma, AA
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (01) : 81 - 89
  • [4] A new tool for molecular imaging:: The microvolumetric β blood counter
    Convert, Laurence
    Morin-Brassard, Guillaume
    Cadorette, Jules
    Archambault, Melanie
    Bentourkia, M'hamed
    Lecomte, Roger
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1197 - 1206
  • [5] EFFECT OF BLOOD CURVE SMEARING ON THE ACCURACY OF PARAMETER ESTIMATES OBTAINED FOR RB-82/PET STUDIES OF BLOOD-BRAIN BARRIER PERMEABILITY
    DHAWAN, V
    JARDEN, JO
    STROTHER, S
    ROTTENBERG, DA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01) : 61 - 74
  • [6] Eberl S, 1997, EUR J NUCL MED, V24, P299, DOI 10.1007/s002590050056
  • [7] ERIKSSON L, 1991, MED PROG TECHNOL, V17, P249
  • [8] Extraction of functional volumes from medical dynamic volumetric data sets
    Frouin, F.
    Cinotti, L.
    Benali, H.
    Buvat, I.
    Bazin, J.-P.
    Millet, P.
    Di Paola, R.
    [J]. Computerized Medical Imaging and Graphics, 1993, 17 (4-5) : 397 - 404
  • [9] GAMBHIR SS, 1989, J NUCL MED, V30, P359
  • [10] A CONTINUOUS-FLOW INPUT FUNCTION DETECTOR FOR H-2 O-15 BLOOD-FLOW STUDIES IN POSITRON EMISSION TOMOGRAPHY
    HUTCHINS, GD
    HICHWA, RD
    KOEPPE, RA
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 546 - 549