Utilization of large volume zwitterionic hydrophilic interaction liquid chromatography for the analysis of polar pharmaceuticals in aqueous environmental samples: Benefits and limitations

被引:53
作者
Boulard, Lise [1 ]
Dierkes, Georg [1 ]
Ternes, Thomas [1 ]
机构
[1] Fed Inst Hydrol BfG, Mainzer Tor 1, D-56068 Koblenz, Germany
关键词
HILIC; Freeze-drying; HILIC robustness; Matrix effect; Pharmaceutical; Environmental sample; TANDEM MASS-SPECTROMETRY; PERSONAL CARE PRODUCTS; SOLID-PHASE EXTRACTION; WASTE-WATER TREATMENT; ANTIDIABETIC DRUG METFORMIN; ILLICIT DRUGS; TRANSFORMATION PRODUCTS; STATIONARY PHASES; AQUATIC ENVIRONMENT; RISK-ASSESSMENT;
D O I
10.1016/j.chroma.2017.12.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Benefits and limitations of HILIC were studied for the analysis of extreme polar organic contaminants in aqueous environmental matrices. A sensitive analytical method was developed and validated for the detection of 11 pharmaceuticals, 15 pharmaceutical metabolites and transformation products and the artificial sweetener acesulfame in aqueous environmental samples. The analytical method consisted of a simple and non-specific sample preparation based on freeze-drying followed by detection with large injection volume (70 mu L) zwitterionic HILIC-ESI-MS/MS. Robustness studies showed a high sensitivity of the retention times and peak shapes to variations of the acetonitrile/water ratio of both the eluent and the diluent. Thus, a thorough sample and eluent preparation is required to obtain reproducible results. Extreme matrix effects of >200% were observed for emtricitabine and acyclovir, which could be traced to the co-elution of nitrate and chloride, respectively. These matrix effects and those of other analytes could be efficiently compensated by using deuterated, C-13 and N-15-labeled internal standards. The developed method was able to detect the selected 27 analytes in treated wastewater, surface water and groundwater down to limit of quantification (LOQ) in the lower ng/L range. Appreciable concentrations were detected, ranging up to 110 mu g/L (guanyl urea) in treated wastewater, up to 5.1 mu g/L (oxipurinol) in surface water and up to 6.1 mu g/L (acesulfame) in groundwater. In a German drinking water, only the X-ray contrast medium diatrizoate and the artificial sweetener acesulfame were quantified above LOQ with 0.19 mu g/L and 0.35 mu g/L, respectively. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 43
页数:17
相关论文
共 41 条
[21]   Microextraction procedures combined with large volume injection in capillary gas chromatography for the determination of pesticide residues in environmental aqueous samples [J].
Beltran, J ;
López, FJ ;
Forcada, M ;
Hernandez, F .
ANALYTICA CHIMICA ACTA, 1997, 356 (2-3) :125-133
[23]   Trace analysis of environmental matrices by large-volume injection and liquid chromatography–mass spectrometry [J].
Francesco Busetti ;
Will J. Backe ;
Nina Bendixen ;
Urs Maier ;
Benjamin Place ;
Walter Giger ;
Jennifer A. Field .
Analytical and Bioanalytical Chemistry, 2012, 402 :175-186
[24]   Hydrophilic interaction liquid chromatography-tandem mass spectrometry methylphosponic and alkyl methylphosphonic acids determination in environmental samples after pre-column derivatization with p-bromophenacyl bromide [J].
Baygildiev, T. M. ;
Rodin, I. A. ;
Stavrianidi, A. N. ;
Braun, A. V. ;
Lebedev, A. T. ;
Rybalchenko, I. V. ;
Shpigun, O. A. .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1442 :19-25
[25]   Analysis of trace organic compounds in environmental, food and biological matrices using large-volume sample injection in column-switching liquid chromatography [J].
Fernandez-Ramos, Carolina ;
Satinsky, Dalibor ;
Smidova, Barbora ;
Solich, Petr .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 62 :69-85
[26]   Trace analysis of environmental matrices by large-volume injection and liquid chromatography-mass spectrometry [J].
Busetti, Francesco ;
Backe, Will J. ;
Bendixen, Nina ;
Maier, Urs ;
Place, Benjamin ;
Giger, Walter ;
Field, Jennifer A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) :175-186
[27]   Separation with zwitterionic hydrophilic interaction liquid chromatography improves protein identification by matrix-assisted laser desorption/ionization-based proteomic analysis [J].
Intoh, Atsushi ;
Kurisaki, Akira ;
Fukuda, Hiroyuki ;
Asashima, Makoto .
BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (06) :607-614
[28]   Online solid phase extraction liquid chromatography using bonded zwitterionic stationary phases and tandem mass spectrometry for rapid environmental trace analysis of highly polar hydrophilic compounds - Application for the antiviral drug Zanamivir [J].
Lindberg, Richard H. ;
Fedorova, Ganna ;
Blum, Kristin M. ;
Pulit-Prociak, Jolanta ;
Gillman, Anna ;
Jarhult, Josef ;
Appelblad, Patrik ;
Soderstrom, Hanna .
TALANTA, 2015, 141 :164-169
[29]   Analysis of Androgenic Steroids in Environmental Waters by Large-Volume Injection Liquid Chromatography Tandem Mass Spectrometry [J].
Backe, Will J. ;
Ort, Christoph ;
Brewer, Alex J. ;
Fidel, Jennifer A. .
ANALYTICAL CHEMISTRY, 2011, 83 (07) :2622-2630
[30]   Free Amino Acid Analysis in Honey Samples by Hydrophilic Interaction Liquid Chromatography with UV Detection Using Precolumn Derivatization with Dansyl Chloride [J].
Kirkan, Ertug ;
Aydogan, Cemil .
CHROMATOGRAPHIA, 2021, 84 (02) :127-133