Utilization of large volume zwitterionic hydrophilic interaction liquid chromatography for the analysis of polar pharmaceuticals in aqueous environmental samples: Benefits and limitations

被引:52
作者
Boulard, Lise [1 ]
Dierkes, Georg [1 ]
Ternes, Thomas [1 ]
机构
[1] Fed Inst Hydrol BfG, Mainzer Tor 1, D-56068 Koblenz, Germany
关键词
HILIC; Freeze-drying; HILIC robustness; Matrix effect; Pharmaceutical; Environmental sample; TANDEM MASS-SPECTROMETRY; PERSONAL CARE PRODUCTS; SOLID-PHASE EXTRACTION; WASTE-WATER TREATMENT; ANTIDIABETIC DRUG METFORMIN; ILLICIT DRUGS; TRANSFORMATION PRODUCTS; STATIONARY PHASES; AQUATIC ENVIRONMENT; RISK-ASSESSMENT;
D O I
10.1016/j.chroma.2017.12.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Benefits and limitations of HILIC were studied for the analysis of extreme polar organic contaminants in aqueous environmental matrices. A sensitive analytical method was developed and validated for the detection of 11 pharmaceuticals, 15 pharmaceutical metabolites and transformation products and the artificial sweetener acesulfame in aqueous environmental samples. The analytical method consisted of a simple and non-specific sample preparation based on freeze-drying followed by detection with large injection volume (70 mu L) zwitterionic HILIC-ESI-MS/MS. Robustness studies showed a high sensitivity of the retention times and peak shapes to variations of the acetonitrile/water ratio of both the eluent and the diluent. Thus, a thorough sample and eluent preparation is required to obtain reproducible results. Extreme matrix effects of >200% were observed for emtricitabine and acyclovir, which could be traced to the co-elution of nitrate and chloride, respectively. These matrix effects and those of other analytes could be efficiently compensated by using deuterated, C-13 and N-15-labeled internal standards. The developed method was able to detect the selected 27 analytes in treated wastewater, surface water and groundwater down to limit of quantification (LOQ) in the lower ng/L range. Appreciable concentrations were detected, ranging up to 110 mu g/L (guanyl urea) in treated wastewater, up to 5.1 mu g/L (oxipurinol) in surface water and up to 6.1 mu g/L (acesulfame) in groundwater. In a German drinking water, only the X-ray contrast medium diatrizoate and the artificial sweetener acesulfame were quantified above LOQ with 0.19 mu g/L and 0.35 mu g/L, respectively. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 43
页数:17
相关论文
共 41 条
  • [1] Application of hydrophilic interaction chromatography for the analysis of polar contaminants in food and environmental samples
    van Nuijs, Alexander L. N.
    Tarcomnicu, Isabela
    Covaci, Adrian
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (35) : 5964 - 5974
  • [2] Large volume injection of aqueous peptide samples on a monolithic silica based zwitterionic-hydrophilic interaction liquid chromatography system for characterization of posttranslational modifications
    Malerod, Helle
    Rogeberg, Magnus
    Tanaka, Nobuo
    Greibrokk, Tyge
    Lundanes, Elsa
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1317 : 129 - 137
  • [3] Hydrophilic interaction liquid chromatography (HILIC) with DAD detection for the determination of relatively non polar fungicides in orange samples
    Hassan, Yasmeen A. A.
    Ayad, Miriam F.
    Hussein, Lobna A.
    Fares, Nermine, V
    MICROCHEMICAL JOURNAL, 2023, 193
  • [4] Hydrophilic Interaction Liquid Chromatography and Per Aqueous Liquid Chromatography in Fungicides Analysis
    Noga, Sylwia
    Felinger, Attila
    Buszewski, Boguslaw
    JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (05) : 1362 - 1370
  • [5] Insights into the Mechanism of Separation of Bisphosphonates by Zwitterionic Hydrophilic Interaction Liquid Chromatography: Application to the Quantitation of Risedronate in Pharmaceuticals
    Panderi, Irene
    Taxiarchi, Eugenia
    Pistos, Constantinos
    Kalogria, Eleni
    Vonaparti, Ariadni
    SEPARATIONS, 2019, 6 (01)
  • [6] Analysis of fatty acid samples by hydrophilic interaction liquid chromatography and charged aerosol detector
    Roy, Claude-Eric
    Kauss, Tina
    Prevot, Sandrine
    Barthelemy, Philippe
    Gaudin, Karen
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1383 : 121 - 126
  • [7] Determination of alkyl ammonium ionic liquid cations by hydrophilic interaction liquid chromatography and its application in analysis of environmental water
    Fan, Zi-qiang
    Yu, Hong
    Cai, Ya-qi
    ANALYTICAL METHODS, 2018, 10 (24) : 2812 - 2820
  • [8] The determination of acrylamide in environmental and drinking waters by large-volume injection - hydrophilic-interaction liquid chromatography and tandem mass spectrometry
    Backe, Will J.
    Yingling, Virginia
    Johnson, Todd
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1334 : 72 - 78
  • [9] Hydrophilic interaction liquid chromatography coupled to mass spectrometry-based detection to determine emerging organic contaminants in environmental samples
    Salas, Daniela
    Borrull, Francesc
    Fontanals, Nuria
    Maria Marce, Rosa
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 94 : 141 - 149
  • [10] Large Volume Injection of Aqueous Samples in Nano Liquid Chromatography Using Serially Coupled Columns
    Leonhardt, Juri
    Hetzel, Terence
    Teutenberg, Thorsten
    Schmidt, Torsten C.
    CHROMATOGRAPHIA, 2015, 78 (1-2) : 31 - 38