Prosthetic Graft Infection, Five Years After Ascending Aortic Replacement

被引:3
作者
Altarabsheh, Salah Eldien [1 ]
Deo, Salil V. [1 ]
Berbari, Elie [2 ]
Park, Soon J. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Surg, Rochester, MN 55905 USA
[2] Mayo Clin, Div Infect Dis, Rochester, MN USA
关键词
D O I
10.1111/j.1540-8191.2012.01402.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fifty-year-old male developed an infected perigraft collection five years following wrapping of a Dacron tube with residual aneurysmal ascending aortic tissue. Treatment consisted of excision of the graft, debridement of the infected surrounding tissues, and replacement using a rifampin-soaked Hemashield tube graft. This case demonstrates the potential risk of wrapping prosthetic grafts with native aneurysmal aortic tissue.
引用
收藏
页码:220 / 221
页数:2
相关论文
共 5 条
[1]   Treatment of deep infection following thoracic aorta graft replacement without graft removal [J].
Kaneda, T ;
Iemura, J ;
Oka, H ;
Inoue, T ;
Zhang, ZW ;
Matsumoto, T ;
Onoe, M ;
Otaki, M ;
Oku, H ;
Ishigami, N ;
Aoshima, M .
ANNALS OF VASCULAR SURGERY, 2001, 15 (04) :430-434
[2]   ROLE OF WRAPPING IN CONCOMITANT INTRAABDOMINAL ANEURYSM AND COLORECTAL-CARCINOMA - REPORT OF 3 CASES [J].
MINU, AR ;
TAKEMURA, K ;
IWAI, T ;
TSUBAKI, M ;
SATO, S ;
ENDO, M .
DISEASES OF THE COLON & RECTUM, 1992, 35 (10) :991-995
[3]   A case of graft infection 10 years after ascending aorta replacement [J].
Miyazaki, S ;
Fukushima, K ;
Sawaki, D ;
Otani, Y ;
Sekita, G ;
Takeuchi, H ;
Adachi, H ;
Ino, T ;
Aoyagi, T .
ANNALS OF VASCULAR SURGERY, 2004, 18 (06) :755-757
[4]   POSTOPERATIVE EVALUATION OF ASCENDING AORTIC PROSTHETIC CONDUITS BY MAGNETIC-RESONANCE IMAGING [J].
PUCILLO, AL ;
SCHECHTER, AG ;
MOGGIO, RA ;
KAY, RH ;
TENNER, MS ;
HERMAN, MV .
CHEST, 1990, 97 (01) :106-110
[5]   SURGICAL-TREATMENT OF INFECTED COMPOSITE GRAFT AFTER REPLACEMENT OF ASCENDING AORTA [J].
SOYER, R ;
BESSOU, JP ;
BOUCHART, F ;
REDONNET, M ;
MOUTONSCHLEIFER, D ;
ARRIGNON, J .
ANNALS OF THORACIC SURGERY, 1994, 58 (02) :425-428