Probing the sensitivity of the resonant frequency analysis to the dental implant-bone condition: A numerical study

被引:1
作者
Chen, S. [1 ]
Rittel, D. [1 ]
Shemtov-Yona, K. [1 ,2 ]
机构
[1] Technion, Fac Mech Engn, IL-32000 Haifa, Israel
[2] Tel Aviv Univ, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Oral Biol, Tel Aviv, Israel
关键词
Dental implant; Osseointegration; Resonant frequency analysis; Peri-implantitis; Finite element model; ALTERS MATERIAL PROPERTIES; STABILITY QUOTIENT; TITANIUM IMPLANTS; CORTICAL BONE; CONTACT; OSSEOINTEGRATION; EXTRACTION; INTERFACE;
D O I
10.1016/j.jmbbm.2022.105128
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The resonant frequency analysis (RFA) is a routinely used technique to assess dental implant stability. However, its sensitivity to the condition of the bone-implant interface remains largely unexplored. This paper investigates the RFA by means of numerical (finite element) simulations of short conical implants inserted into realistic jawbone sections. Two cases are examined. The first consists of a systematic variation in the bone-implant contact (BIC) using a random generation of the contact points in the two bone components. The results of the analyses show that beyond a BIC of ca. 20%, the RFA does not vary significantly, indicating a lack of sensitivity to further osseointegration. The next topic concerns peri-implantitis, as simulated firstly by a deterministic progressive detachment of the bone-implant interface. The main result of this simulation is that the RFA-BIC relationship is radically different for the osseointegration and bone recess phases, indicating a sensitivity to the location of the BIC in the bone components (random vs. deterministic). Finally, the simulation of a realistic peri-implantitis cylindrical crater of various depths shows no difference with respect to the previously analyzed interfacial bone detachment, indicating that the exact geometry of the peri-implantitis crater is of little if no influence on the RFA results.
引用
收藏
页数:7
相关论文
共 34 条
[1]   Hard tissue implant interface [J].
Albrektsson, T. .
AUSTRALIAN DENTAL JOURNAL, 2008, 53 :S34-S38
[2]   OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[3]  
BRUNSKI J B, 1992, Clinical Materials, V10, P153, DOI 10.1016/0267-6605(92)90049-Y
[4]   The normal stiffness of the edentulous alveolar process [J].
Chen, S. ;
Rittel, D. ;
Yona, K. Shemtov .
BONE REPORTS, 2021, 14
[5]   Edentulation Alters Material Properties of Cortical Bone in the Human Craniofacial Skeleton: Functional Implications for Craniofacial Structure in Primate Evolution [J].
Dechow, Paul C. ;
Wang, Qian ;
Peterson, Jill .
ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2010, 293 (04) :618-629
[6]   Biomechanical behaviours of the bone-implant interface: a review [J].
Gao, Xing ;
Fraulob, Manon ;
Haiat, Guillaume .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2019, 16 (156)
[7]   Effects of Biomechanical Properties of the Bone-Implant Interface on Dental Implant Stability: From In Silico Approaches to the Patient's Mouth [J].
Haiat, Guillaume ;
Wang, Hom-Lay ;
Brunski, John .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 16, 2014, 16 :187-213
[8]   Assessment of dental implant stability using resonance frequency analysis and quantitative ultrasound methods [J].
Heriveaux, Yoann ;
Vayron, Romain ;
Fraulob, Manon ;
Lomami, Hugues Albini ;
Lenormand, Camille ;
Haiat, Guillaume .
JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (03) :421-427
[9]   Relation between initial implant stability quotient and bone-implant contact percentage: an in vitro model study [J].
Huang, Heng-Li ;
Tsai, Ming-Tzu ;
Su, Kuo-Chih ;
Li, Yu-Fen ;
Hsu, Jui-Ting ;
Chang, Chih-Han ;
Fuh, Lih-Jyh ;
Wu, Aaron Yu-Jen .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (05) :E356-E361
[10]   Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments [J].
Ito, Yoshihiro ;
Sato, Daisuke ;
Yoneda, Satoshi ;
Ito, Daisuke ;
Kondo, Hisatomo ;
Kasugai, Shohei .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (01) :9-14