Inflow into saccular cerebral aneurysms at arterial bends

被引:34
作者
Imai, Yohsuke [1 ]
Sato, Kodai [1 ]
Ishikawa, Takuji [1 ]
Yamaguchi, Takami [1 ]
机构
[1] Tohoku Univ, Grad Sch Engn, Dept Bioengn & Robot, Aoba Ku, Sendai, Miyagi 9808579, Japan
基金
日本学术振兴会;
关键词
blood flow; aneurysm; endovascular devices; computational fluid dynamics; inflow flux; secondary flow;
D O I
10.1007/s10439-008-9522-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To identify shortcomings in the design of conventional endovascular devices, we investigated the inflow features of untreated aneurysms at a variety of arterial bends using computational fluid dynamics. As a preliminary study, we analyzed the steady-state inflow for aneurysms created at U-shaped, twisted, and S-shaped arteries. Both the inflow pattern and inflow flux were strongly influenced by the shape of the artery and the configuration angle of the aneurysm to the artery. We revealed that the secondary flow generated in the parent artery is the dominant factor affecting the inflow. Our results suggest that the arterial geometry and secondary flow should be considered in the design of endovascular devices.
引用
收藏
页码:1489 / 1495
页数:7
相关论文
共 26 条
[1]   CFD modeling of blood flow following coil embolization of aneurysms [J].
Byun, HS ;
Rhee, K .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (09) :755-761
[2]  
Castro MA, 2006, AM J NEURORADIOL, V27, P1703
[3]   Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique [J].
Cebral, JR ;
Löhner, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :468-476
[4]   On the effect of parent-aneurysm angle on flow patterns in basilar tip aneurysms: Towards a surrogate geometric marker of intra-aneurismal hemodynamics [J].
Ford, Matthew D. ;
Lee, Sang-Wook ;
Lownie, Stephen P. ;
Holdsworth, David W. ;
Steinman, David A. .
JOURNAL OF BIOMECHANICS, 2008, 41 (02) :241-248
[5]   IN-VITRO STUDY OF HEMODYNAMICS IN A GIANT SACCULAR ANEURYSM MODEL - INFLUENCE OF NOW DYNAMICS IN THE PARENT VESSEL AND EFFECTS OF COIL EMBOLIZATION [J].
GOBIN, YP ;
COUNORD, JL ;
FLAUD, P ;
DUFFAUX, J .
NEURORADIOLOGY, 1994, 36 (07) :530-536
[6]   ENDOVASCULAR TREATMENT OF POSTERIOR CIRCULATION ANEURYSMS BY ELECTROTHROMBOSIS USING ELECTRICALLY DETACHABLE COILS [J].
GUGLIELMI, G ;
VINUELA, F ;
DUCKWILER, G ;
DION, J ;
LYLYK, P ;
BERENSTEIN, A ;
STROTHER, C ;
GRAVES, V ;
HALBACH, V ;
NICHOLS, D ;
HOPKINS, N ;
FERGUSON, R ;
SEPETKA, I .
JOURNAL OF NEUROSURGERY, 1992, 77 (04) :515-524
[7]  
Isoda H, 2006, AM J NEURORADIOL, V27, P1119
[8]   Comparison of CFD and MRI flow and velocities in an in vitro large artery bypass graft model [J].
Ku, JP ;
Elkins, CJ ;
Taylor, CA .
ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (03) :257-269
[9]   Intra-aneurysmal flow with helix and mesh stent placement across side-wall aneurysm pore of a straight parent vessel [J].
Liou, TM ;
Liou, SN ;
Chu, KL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01) :36-43
[10]   Numerical and experimental studies on pulsatile flow in aneurysms arising laterally from a curved parent vessel at various angles [J].
Liou, Tong-Miin ;
Yi-Chen, L. ;
Juan, Wei-Cheng .
JOURNAL OF BIOMECHANICS, 2007, 40 (06) :1268-1275