Determination of nitroaromatic explosives in water samples by direct ultrasound-assisted dispersive liquid-liquid rnicroextraction followed by gas chromatography-mass spectrometry

被引:54
作者
Cortada, Carol [1 ]
Vidal, Lorena [2 ,3 ]
Canals, Antonio [2 ,3 ]
机构
[1] Labaqua SA, Alicante 03114, Spain
[2] Univ Alicante, Dept Quim Analit Nutr & Bromatol, E-03080 Alicante, Spain
[3] Univ Alicante, Inst Univ Mat, E-03080 Alicante, Spain
关键词
Nitroaromatic explosives; Direct ultrasound-assisted dispersive liquid-liquid microextraction; Gas chromatography-mass spectrometry; D-optimal design; Expanded uncertainty; Water; SINGLE-DROP MICROEXTRACTION; EMULSIFICATION-MICROEXTRACTION; IONIC LIQUID; PESTICIDES; OPTIMIZATION; EXTRACTION; SOLVENT;
D O I
10.1016/j.talanta.2011.08.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, simple, inexpensive, sensitive, efficient and environmental friendly direct ultrasound-assisted dispersive liquid-liquid microextraction (DUSA-DLLME) procedure has been developed to concentrate five nitroaromatic explosives from water samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). An efficient ultrasonic probe has been used to radiate directly the samples producing very fine emulsions from immiscible liquids. A D-optimal design was used for optimizing the factors and to evaluate their influential upon extraction. The optimum experimental conditions were: sample volume, 10 mL; extraction time, 60s: cycles, 0.6 s(s(-1)); power of ultrasound energy, 40% (70W): and, extractant solvent (chlorobenzene) volume, 20 mu L. Under the optimized experimental conditions the method presents good level of repeatability with coefficients of variation under 6% (n = 8; spiking level 10 mu g L-1). Calculated calibration curves gave high level of linearity with correlation coefficient values between 0.9949 and 0.9992. Limits of detection were ranged between 0.03 and 0.91 mu g L-1. Finally, the proposed method was applied to the analysis of two types of water samples, reservoir and effluent wastewater. The samples were previously analysed and confirmed free of target analytes. At 5 mu g L-1 spiking level recovery values ranged between 75 and 96% for reservoir water sample showing that the matrix had a negligible effect upon extraction. However, a noticeable matrix effect (around 50% recovery) was observed for effluent wastewater sample. In order to alleviate this matrix effect, the standard addition calibration method was used for quantitative determination. This calibration method supplied recovery values ranged between 71 and 79%. The same conclusions have been obtained from an uncertainty budget evaluation study. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2546 / 2552
页数:7
相关论文
共 30 条
[1]  
[Anonymous], 2000, DESIGN ANAL EXPT
[2]  
[Anonymous], TRENDS ANAL CHEM
[3]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[4]   Determination of geosmin and 2-methylisoborneol in water and wine samples by ultrasound-assisted dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry [J].
Cortada, Carol ;
Vidal, Lorena ;
Canals, Antonio .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (01) :17-22
[5]   Determination of organochlorine pesticides in complex matrices by single-drop microextraction coupled to gas chromatography-mass spectrometry [J].
Cortada, Carol ;
Vidal, Lorena ;
Tejada, Sergio ;
Romo, Alicia ;
Canals, Antonio .
ANALYTICA CHIMICA ACTA, 2009, 638 (01) :29-35
[6]   Trace explosives signatures from World War II unexploded undersea ordnance [J].
Darrach, MR ;
Chutjian, A ;
Plett, GA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (09) :1354-1358
[7]   Ultrasound-assisted preparation of liquid samples [J].
de Castro, M. D. Luque ;
Priego-Capote, F. .
TALANTA, 2007, 72 (02) :321-334
[8]  
DURBIN J, 1950, BIOMETRIKA, V37, P409, DOI 10.1093/biomet/37.3-4.409
[9]   Optimization of dispersive liquid-liquid microextraction combined with gas chromatography for the analysis of nitroaromatic compounds in water [J].
Ebrahimzadeh, Homeira ;
Yamini, Yadollah ;
Kamarei, Fahimeh .
TALANTA, 2009, 79 (05) :1472-1477
[10]   Simple approach based on ultrasound-assisted emulsification-microextraction for determination of polibrominated flame retardants in water samples by gas chromatography-mass spectrometry [J].
Fontana, Ariel R. ;
Wuilloud, RodolfoG. ;
Martinez, Luis D. ;
Altamirano, Jorgelina C. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (01) :147-153