Improved Automatic Detection of New T2 Lesions in Multiple Sclerosis Using Deformation Fields

被引:27
|
作者
Cabezas, M. [1 ,3 ]
Corral, J. F. [1 ]
Oliver, A. [3 ]
Diez, Y. [3 ]
Tintore, M. [2 ]
Auger, C. [1 ]
Montalban, X. [2 ]
Llado, X. [3 ]
Pareto, D. [1 ]
Rovira, A. [1 ]
机构
[1] Autonomous Univ Barcelona, Vall dHebron Res Inst, Vall dHebron Univ Hosp, Sect Neuroradiol,Dept Radiol, Barcelona, Spain
[2] Autonomous Univ Barcelona, Ctr Esclerosi Multiple Catalunya, Vall dHebron Univ Hosp, Dept Neurol Neuroimmunol,Vall dHebron Res Inst, Barcelona, Spain
[3] Univ Girona, Visio Comp & Robt Grp, Girona, Spain
关键词
BRAIN MRI; DISEASE-ACTIVITY; INTERFERON-BETA; RECOMMENDATIONS; IMAGES; MS;
D O I
10.3174/ajnr.A4829
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Detection of disease activity, defined as new/enlarging T2 lesions on brain MR imaging, has been proposed as a biomarker in MS. However, detection of new/enlarging T2 lesions can be hindered by several factors that can be overcome with image subtraction. The purpose of this study was to improve automated detection of new T2 lesions and reduce user interaction to eliminate inter- and intraobserver variability. MATERIALS AND METHODS: Multiparametric brain MR imaging was performed at 2 time points in 36 patients with new T2 lesions. Images were registered by using an affine transformation and the Demons algorithm to obtain a deformation field. After affine registration, images were subtracted and a threshold was applied to obtain a lesion mask, which was then refined by using the deformation field, intensity, and local information. This pipeline was compared with only applying a threshold, and with a state-of-the-art approach relying only on image intensities. To assess improvements, we compared the results of the different pipelines with the expert visual detection. RESULTS: The multichannel pipeline based on the deformation field obtained a detection Dice similarity coefficient close to 0.70, with a false-positive detection of 17.8% and a true-positive detection of 70.9%. A statistically significant correlation (r = 0.81, P value = 2.2688e-09) was found between visual detection and automated detection by using our approach. CONCLUSIONS: The deformation field-based approach proposed in this study for detecting new/enlarging T2 lesions resulted in significantly fewer false-positives while maintaining most true-positives and showed a good correlation with visual detection annotations. This approach could reduce user interaction and inter- and intraobserver variability.
引用
收藏
页码:1816 / 1823
页数:8
相关论文
共 50 条
  • [1] A supervised framework with intensity subtraction and deformation field features for the detection of new T2-w lesions in multiple sclerosis
    Salem, Mostafa
    Cabezas, Mariano
    Valverde, Sergi
    Pareto, Deborah
    Oliver, Arnau
    Salvi, Joaquim
    Rovira, Alex
    Llado, Xavier
    NEUROIMAGE-CLINICAL, 2018, 17 : 607 - 615
  • [2] T2 lesions and rate of progression of disability in multiple sclerosis
    Mostert, J. P.
    Koch, M. W.
    Steen, C.
    Heersema, D. J.
    de Groot, J. C.
    De Keyser, J.
    EUROPEAN JOURNAL OF NEUROLOGY, 2010, 17 (12) : 1471 - 1475
  • [3] Assessment of automatic decision-support systems for detecting active T2 lesions in multiple sclerosis patients
    Rovira, Alex
    Corral, Juan Francisco
    Auger, Cristina
    Valverde, Sergi
    Vidal-Jordana, Angela
    Oliver, Arnau
    de Barros, Andrea
    Ng Wong, Yiken Karelys
    Tintore, Mar
    Pareto, Deborah
    Aymerich, Francesc Xavier
    Montalban, Xavier
    Llado, Xavier
    Alonso, Juli
    MULTIPLE SCLEROSIS JOURNAL, 2022, 28 (08) : 1209 - 1218
  • [4] The Central Vein Sign in Multiple Sclerosis Lesions Is Present Irrespective of the T2*Sequence at 3 T
    Samaraweera, Amal P. R.
    Clarke, Margareta A.
    Whitehead, Amy
    Falah, Yasser
    Driver, Ian D.
    Dineen, Robert A.
    Morgan, Paul S.
    Evangelou, Nikos
    JOURNAL OF NEUROIMAGING, 2017, 27 (01) : 114 - 121
  • [5] Improved detection of focal cortical lesions using 7 T magnetisation transfer imaging in patients with multiple sclerosis
    Abdel-Fahim, R.
    Mistry, N.
    Mougin, O.
    Blazejewska, A.
    Pitiot, A.
    Retkute, R.
    Gowland, P.
    Evangelou, N.
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2014, 3 (02) : 258 - 265
  • [6] Gadolinium-enhancing or active T2 magnetic resonance imaging lesions in multiple sclerosis clinical trials?
    Bonzano, L.
    Roccatagliata, L.
    Mancardi, G. L.
    Sormani, M. P.
    MULTIPLE SCLEROSIS JOURNAL, 2009, 15 (09) : 1043 - 1047
  • [7] Ultra-High-Field MRI Visualization of Cortical Multiple Sclerosis Lesions with T2 and T2*: A Postmortem MRI and Histopathology Study
    Jonkman, L. E.
    Klaver, R.
    Fleysher, L.
    Inglese, M.
    Geurts, J. J. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (11) : 2062 - 2067
  • [8] Fully automatic detection of deep white matter T1 hypointense lesions in multiple sclerosis
    Spies, Lothar
    Tewes, Anja
    Suppa, Per
    Opfer, Roland
    Buchert, Ralph
    Winkler, Gerhard
    Raji, Alaleh
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (23) : 8323 - 8337
  • [9] Serum neurofilament light chain is more strongly associated with T2 lesion volume than with number of T2 lesions in patients with multiple sclerosis
    Wenger, Katharina J.
    Hoelter, Maya C.
    Yalachkov, Yavor
    Schaefer, Jan Hendrik
    Oezkan, Dilek
    Steffen, Falk
    Bittner, Stefan
    Hattingen, Elke
    Foerch, Christian
    Schaller-Paule, Martin A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166
  • [10] Improved Detection of Active Multiple Sclerosis Lesions: 3D Subtraction Imaging
    Moraal, Bastiaan
    Wattjes, Mike P.
    Geurts, Jeroen J. G.
    Knol, Dirk L.
    van Schijndel, Ronald A.
    Pouwels, Petra J. W.
    Vrenken, Hugo
    Barkhof, Frederik
    RADIOLOGY, 2010, 255 (01) : 154 - 163