Prevention of 3 "Never Events" in the Operating Room: Fires, Gossypiboma, and Wrong-Site Surgery

被引:24
作者
Zahiri, Hamid R.
Stromberg, Jeffrey [2 ]
Skupsky, Hadas
Knepp, Erin K.
Folstein, Matthew
Silverman, Ronald
Singh, Devinder [1 ]
机构
[1] Univ Maryland, Sch Med, Div Plast Surg, Baltimore, MD 21201 USA
[2] Cleveland Clin Hosp, Cleveland, OH USA
关键词
ergonomics and/or human factors study; evidence-based medicine/surgery; surgical education; PATIENT SAFETY; CHECKLIST; ANESTHESIOLOGISTS; COMMUNICATION; INSTRUMENTS; FREQUENCY; FAILURES; SPONGES; RISK;
D O I
10.1177/1553350610389196
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: This study sought to identify and provide preventative recommendations for potentially devastating safety violations in the operating room. Methods: A Medline database search from 1950 to current using the terms patient safety and operating room was conducted. All topics identified were reviewed. Three patient safety violations with potential for immediate and devastating outcomes were selected for discussion using evidence-based literature. Results: The search identified 2851 articles, 807 of which were directly related to patient safety in the operating room. Topics addressed by these 807 included infectious complications (26%), fires (11%), communication/teamwork (6%), retained foreign objects (3%), safety checklists (1%), and wrong-site surgery (1%). Fires, gossypiboma, and wrong-site surgery were selected for discussion. Conclusions: Although fire, gossypiboma, and wrong-site surgery should be "never events" in the operating room, they continue to persist as 3 common patient safety violations. This study provides the epidemiology, common etiologies, and evidence-based preventative recommendations for each.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 32 条
  • [11] Managing the prevention of retained surgical instruments - What is the value of counting?
    Egorova, Natalia N.
    Moskowitz, Alan
    Gelijns, Annetine
    Weinberg, Alan
    Curty, James
    Rabin-Fastman, Barbara
    Kaplan, Harold
    Cooper, Mary
    Fowler, Dennis
    Emond, Jean C.
    Greco, Giampaolo
    [J]. ANNALS OF SURGERY, 2008, 247 (01) : 13 - 18
  • [12] *EM CAR RES I, ONL YOU CAN PREV SUR
  • [13] Risk factors for retained instruments and sponges after surgery
    Gawande, AA
    Studdert, DM
    Orav, EJ
    Brennan, TA
    Zinner, MJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (03) : 229 - 235
  • [14] The frequency and significance of discrepancies in the surgical count
    Greenberg, Caprice C.
    Regenbogen, Scott E.
    Lipsitz, Stuart R.
    Diaz-Flores, Rafael
    Gawande, Atul A.
    [J]. ANNALS OF SURGERY, 2008, 248 (02) : 337 - 341
  • [15] Beyond counting: Current evidence on the problem of retaining foreign bodies in surgery?
    Greenberg, Caprice C.
    Gawande, Atul A.
    [J]. ANNALS OF SURGERY, 2008, 247 (01) : 19 - 20
  • [16] A Surgical Safety Checklist to Reduce Morbidity and Mortality in a Global Population.
    Haynes, Alex B.
    Weiser, Thomas G.
    Berry, William R.
    Lipsitz, Stuart R.
    Breizat, Abdel-Hadi S.
    Dellinger, E. Patchen
    Herbosa, Teodoro
    Joseph, Sudhir
    Kibatala, Pascience L.
    Lapitan, Marie Carmela M.
    Merry, Alan F.
    Moorthy, Krishna
    Reznick, Richard K.
    Taylor, Bryce
    Gawande, Atul A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (05) : 491 - 499
  • [17] The retained surgical sponge
    Kaiser, CW
    Friedman, S
    Spurling, KP
    Slowick, T
    Kaiser, HA
    [J]. ANNALS OF SURGERY, 1996, 224 (01) : 79 - 84
  • [18] Kohn LT, 2000, ERR IS HUMAN BUILDIN
  • [19] Incidence, patterns, and prevention of wrong-site surgery
    Yeston, N
    Kwaan
    Kenney, P
    Hirsch, E
    [J]. ARCHIVES OF SURGERY, 2006, 141 (04) : 357 - 358
  • [20] Communication failures in the operating room: an observational classification of recurrent types and effects
    Lingard, L
    Espin, S
    Whyte, S
    Regehr, G
    Baker, GR
    Reznick, R
    Bohnen, J
    Orser, B
    Doran, D
    Grober, E
    [J]. QUALITY & SAFETY IN HEALTH CARE, 2004, 13 (05): : 330 - 334