Behaviour and residual compression resistances of circular high strength concrete-filled stainless steel tube (HCFSST) stub columns after exposure to fire

被引:38
作者
He, An [1 ]
Liang, Yating [2 ]
Zhao, Ou [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore, Singapore
[2] Univ Glasgow, Sch Engn, Glasgow, Lanark, Scotland
关键词
Compression tests; Design standards; Heat transfer and mechanical analysis; High strength concrete-filled stainless steel tube (HCFSST) stub columns; ISO-834 Standard fire; Material testing; Numerical simulation; Post-fire residual strengths; COMBINED AXIAL LOAD; STRUCTURAL PERFORMANCE; HOLLOW SECTIONS; DESIGN; CHS;
D O I
10.1016/j.engstruct.2019.109897
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The structural behaviour and residual compression resistances of circular high strength concrete-filled stainless steel tube (HCFSST) stub columns after exposure to fire were experimentally and numerically investigated in this paper. The experimental study was performed on 12 circular HCFSST stub column specimens after exposure to the ISO-834 standard fire for three levels of heating durations (15 min, 30 min and 45 min) as well as 4 unheated circular HCFSST stub column specimens (i.e. reference specimens). The experimental study was supplemented by a numerical modelling study, where two types of finite element (FE) models, namely heat transfer and mechanical FE models, were firstly developed to simulate the thermal and mechanical responses of the circular HCFSST stub column specimens, and then used to perform parametric studies to derive additional numerical results. Due to the lack of existing design codes for concrete-filled stainless steel tube members and concrete-filled carbon steel tube members after exposure to fire, the corresponding codified design provisions for circular concrete-filled carbon steel tube members at room temperature, as established in Europe, Australia and America, were evaluated for their suitability to circular HCFSST stub columns after exposure to fire, based on the test and numerical parametric study results. It was generally found that both the European and Australian codes yield a high level of accuracy and consistency in predicting the residual compression resistances of circular HCFSST stub columns after exposure to fire, while the American specification leads to rather conservative and scattered design residual compression resistances.
引用
收藏
页数:15
相关论文
共 47 条
[1]   Revealing the temperature history in concrete after fire exposure by microscopic analysis [J].
Annerel, E. ;
Taerwe, L. .
CEMENT AND CONCRETE RESEARCH, 2009, 39 (12) :1239-1249
[2]  
[Anonymous], 2009, 1239032009 EN CEN
[3]  
[Anonymous], 2010, 1 COMPLETE DRAFT, DOI DOI 10.35789/FIB.BULL.0055
[4]  
[Anonymous], 1993122005 EN CEN
[5]  
[Anonymous], 2004, EN 1994-1-1
[6]  
[Anonymous], 2009, 68921 EN ISO CEN
[7]  
[Anonymous], ABAQUS STAND US MAN
[8]  
[Anonymous], 2016, AISC 360 16
[9]  
[Anonymous], 2014, 31814 ACI
[10]  
[Anonymous], 2004, AS510062004