Diagnostic Accuracy of Noninvasive Coronary Angiography With 320-Detector Row Computed Tomography

被引:51
|
作者
Nasis, Arthur
Leung, Michael C.
Antonis, Paul R.
Cameron, James D.
Lehman, Sam J.
Hope, Sarah A.
Crossett, Marcus P.
Troupis, John M.
Meredith, Ian T.
Seneviratne, Sujith K. [1 ]
机构
[1] MonashHEART, Monash Cardiovasc Res Ctr, Melbourne, Vic, Australia
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2010年 / 106卷 / 10期
关键词
ATRIAL-FIBRILLATION; ARTERY-DISEASE;
D O I
10.1016/j.amjcard.2010.06.073
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to evaluate the diagnostic accuracy of noninvasive coronary angiography using 320-detector row computed tomography, which provides 16-cm craniocaudal coverage in 350 ms and can image the entire coronary tree in a single heartbeat, representing a significant advance from previous-generation scanners. We evaluated 63 consecutive patients who underwent 320-detector row computed tomography and invasive coronary angiography for the investigation of suspected coronary artery disease. Patients with known coronary artery disease were excluded. Computed tomographic (CT) studies were assessed by 2 independent observers blinded to results of invasive coronary angiography. A single observer unaware of CT results assessed invasive coronary angiographic images quantitatively. All available coronary segments were included in the analysis, regardless of size or image quality. Lesions with >50% diameter stenoses were considered significant. Mean heart rate was 63 +/- 7 beats/min, with 6 patients (10%) in atrial fibrillation during image acquisition. Thirty-three patients (52%) and 70 of 973 segments (7%) had significant coronary stenoses on invasive coronary angiogram. Seventeen segments (2%) were nondiagnostic on computed tomogram and were assumed to contain significant stenoses on an "intention-to-diagnose" analysis. Sensitivity, specificity, and positive and negative predictive values of computed tomography for detecting significant stenoses were 94%, 87%, 88%, and 93%, respectively, by patient (n = 63), 89%, 95%, 82%, and 97%, respectively, by artery (n = 260), and 87%, 97%, 73%, and 99%, respectively, by segment (n = 973). In conclusion, noninvasive 320-detector row CT coronary angiography provides high diagnostic accuracy across all coronary segments, regardless of size, cardiac rhythm, or image quality. 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:1429-1435)
引用
收藏
页码:1429 / 1435
页数:7
相关论文
共 50 条
  • [1] IMPACT OF HEART RATE ON DIAGNOSTIC ACCURACY OF SECOND GENERATION 320-DETECTOR COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY
    Nerlekar, Nitesh
    Nasis, Arthur
    Ko, Brian
    Leung, Michael
    Cameron, James
    Wong, Dennis
    Psaltis, Peter
    Meredith, Ian
    Troupis, John
    Seneviratne, Sujith
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1051 - A1051
  • [2] Impact of heart rate on diagnostic accuracy of second generation 320-detector computed tomography coronary angiography
    Nerlekar, Nitesh
    Ko, Brian S.
    Nasis, Arthur
    Cameron, James D.
    Leung, Michael
    Brown, Adam J.
    Wong, Dennis T. L.
    Ngu, Philip J.
    Troupis, John M.
    Seneviratne, Sujith K.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2017, 7 (03) : 296 - 304
  • [3] Diagnostic Performance Of 320-Detector Row CT Coronary Angiography: a Comparison with Invasive Angiography
    Nasis, Arthur
    Leung, Michael C.
    Antonis, Paul R.
    Cameron, James D.
    Meredith, Ian T.
    Moir, William S.
    Hope, Sarah A.
    Troupis, John M.
    Crossett, Marcus P.
    Seneviratne, Sujith K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 68D - 68D
  • [4] Initial evaluation of coronary images from 320-detector row computed tomography
    Frank J. Rybicki
    Hansel J. Otero
    Michael L. Steigner
    Gabriel Vorobiof
    Leelakrishna Nallamshetty
    Dimitrios Mitsouras
    Hale Ersoy
    Richard T. Mather
    Philip F. Judy
    Tianxi Cai
    Karl Coyner
    Kurt Schultz
    Amanda G. Whitmore
    Marcelo F. Di Carli
    The International Journal of Cardiovascular Imaging, 2008, 24 : 535 - 546
  • [5] Initial evaluation of coronary images from 320-detector row computed tomography
    Rybicki, Frank J.
    Otero, Hansel J.
    Steigner, Michael L.
    Vorobiof, Gabriel
    Nallamshetty, Leelakrishna
    Mitsouras, Dimitrios
    Ersoy, Hale
    Mather, Richard T.
    Judy, Philip F.
    Cai, Tianxi
    Coyner, Karl
    Schultz, Kurt
    Whitmore, Amanda G.
    Di Carli, Marcelo F.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (05): : 535 - 546
  • [6] ACCURACY OF 320-DETECTOR ROW COMPUTED TOMOGRAPHY TO IDENTIFY SIGNIFICANT CORONARY STENOSES IN PATIENTS WITH ATRIAL FIBRILLATION
    Lee, Seitetsu
    Tanabe, Kengo
    Kishi, Satoru
    Otsuka, Tatsuhiko
    Asami, Masahiko
    Watanabe, Mika
    Yoshida, Eri
    Hashimoto, Takuya
    Hara, Hironori
    Yahagi, Kazuyuki
    Nakashima, Makoto
    Aoki, Jiro
    Hara, Kazuhiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1335 - E1335
  • [7] Diagnosis and Treatment of Intracranial Aneurysms with 320-Detector Row Volumetric Computed Tomography Angiography
    Chen, Wenhua
    Xing, Wei
    Peng, Ya
    He, Zhongming
    Wang, Caoye
    Wang, Qi
    WORLD NEUROSURGERY, 2016, 91 : 347 - 356
  • [8] Radiation dose in coronary artery angiography with 320-detector row CT and its diagnostic accuracy: comparison with 64-detector row CT
    Zhang, T.
    Luo, Z. -R.
    Wang, D.
    Han, D.
    Bai, J-Q
    Meng, X. -W.
    Shen, B. -Z.
    MINERVA MEDICA, 2011, 102 (04) : 249 - 259
  • [9] Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study
    Arthur Nasis
    Brian S. Ko
    Michael C. Leung
    Paul R. Antonis
    Dee Nandurkar
    Dennis T. Wong
    Leo Kyi
    James D. Cameron
    John M. Troupis
    Ian T. Meredith
    Sujith K. Seneviratne
    European Radiology, 2013, 23 : 1812 - 1821
  • [10] History of cardiac computed tomography: single to 320-detector row multislice computed tomography
    Gregory S. Hurlock
    Hiroshi Higashino
    Teruhito Mochizuki
    The International Journal of Cardiovascular Imaging, 2009, 25 : 31 - 42