Diagnostic Accuracy of Noninvasive Coronary Angiography With 320-Detector Row Computed Tomography

被引:51
作者
Nasis, Arthur
Leung, Michael C.
Antonis, Paul R.
Cameron, James D.
Lehman, Sam J.
Hope, Sarah A.
Crossett, Marcus P.
Troupis, John M.
Meredith, Ian T.
Seneviratne, Sujith K. [1 ]
机构
[1] MonashHEART, Monash Cardiovasc Res Ctr, Melbourne, Vic, Australia
关键词
ATRIAL-FIBRILLATION; ARTERY-DISEASE;
D O I
10.1016/j.amjcard.2010.06.073
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to evaluate the diagnostic accuracy of noninvasive coronary angiography using 320-detector row computed tomography, which provides 16-cm craniocaudal coverage in 350 ms and can image the entire coronary tree in a single heartbeat, representing a significant advance from previous-generation scanners. We evaluated 63 consecutive patients who underwent 320-detector row computed tomography and invasive coronary angiography for the investigation of suspected coronary artery disease. Patients with known coronary artery disease were excluded. Computed tomographic (CT) studies were assessed by 2 independent observers blinded to results of invasive coronary angiography. A single observer unaware of CT results assessed invasive coronary angiographic images quantitatively. All available coronary segments were included in the analysis, regardless of size or image quality. Lesions with >50% diameter stenoses were considered significant. Mean heart rate was 63 +/- 7 beats/min, with 6 patients (10%) in atrial fibrillation during image acquisition. Thirty-three patients (52%) and 70 of 973 segments (7%) had significant coronary stenoses on invasive coronary angiogram. Seventeen segments (2%) were nondiagnostic on computed tomogram and were assumed to contain significant stenoses on an "intention-to-diagnose" analysis. Sensitivity, specificity, and positive and negative predictive values of computed tomography for detecting significant stenoses were 94%, 87%, 88%, and 93%, respectively, by patient (n = 63), 89%, 95%, 82%, and 97%, respectively, by artery (n = 260), and 87%, 97%, 73%, and 99%, respectively, by segment (n = 973). In conclusion, noninvasive 320-detector row CT coronary angiography provides high diagnostic accuracy across all coronary segments, regardless of size, cardiac rhythm, or image quality. 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:1429-1435)
引用
收藏
页码:1429 / 1435
页数:7
相关论文
共 19 条
[1]  
Austen W G, 1975, Circulation, V51, P5
[2]   Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease [J].
de Graaf, Fleur R. ;
Schuijf, Joanne D. ;
van Velzen, Joella E. ;
Kroft, Lucia J. ;
de Roos, Albert ;
Reiber, Johannes H. C. ;
Boersma, Eric ;
Schalij, Martin J. ;
Spano, Fabrizio ;
Jukema, J. Wouter ;
van der Wall, Ernst E. ;
Bax, Jeroen J. .
EUROPEAN HEART JOURNAL, 2010, 31 (15) :1908-1915
[3]   Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation [J].
Dewey, Marc ;
Zimmermann, Elke ;
Deissenrieder, Florian ;
Laule, Michael ;
Duebel, Hans-Peter ;
Schlattmann, Peter ;
Knebel, Fabian ;
Rutsch, Wolfgang ;
Hamm, Bernd .
CIRCULATION, 2009, 120 (10) :867-875
[4]   ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) :1350-1358
[5]   Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population - Comparison with conventional invasive angiography [J].
Ehara, M ;
Surmely, JF ;
Kawai, M ;
Katoh, O ;
Matsubara, T ;
Terashima, M ;
Tsuchikane, E ;
Kinoshita, Y ;
Suzuki, T ;
Ito, T ;
Takeda, Y ;
Nasu, K ;
Tanaka, N ;
Murata, A ;
Suzuki, Y ;
Sato, K ;
Suzuki, T .
CIRCULATION JOURNAL, 2006, 70 (05) :564-571
[6]   Comparison of accuracy of 64-slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease [J].
Fine, JJ ;
Hopkins, CB ;
Ruff, N ;
Newton, FC .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (02) :173-174
[7]   Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease:: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hadamitzky, Martin ;
Zankl, Maria ;
Gerein, Pia ;
Doerrler, Katharina ;
Kastrati, Adnan ;
Martinoff, Stefan ;
Schoemig, Albert .
EUROPEAN HEART JOURNAL, 2007, 28 (24) :3034-3041
[8]   Estimated Radiation Dose Associated With Cardiac CT Angiography [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hermann, Franziska ;
Hadamitzky, Martin ;
Krebs, Markus ;
Gerber, Thomas C. ;
McCollough, Cynthia ;
Martinoff, Stefan ;
Kastrati, Adnan ;
Schoemig, Albert ;
Achenbach, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :500-507
[9]   Accuracy of MSCT coronary angiography with 64-slice technology:: first experience [J].
Leschka, S ;
Alkadhi, H ;
Plass, A ;
Desbiolles, L ;
Grünenfelder, J ;
Marincek, B ;
Wildermuth, S .
EUROPEAN HEART JOURNAL, 2005, 26 (15) :1482-1487
[10]   Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography [J].
Meijboom, W. Bob ;
Meijs, Matthijs F. L. ;
Schuijf, Joanne D. ;
Cramer, Maarten J. ;
Mollet, Nico R. ;
van Mieghem, Carlos A. G. ;
Nieman, Koen ;
van Werkhoven, Jacob M. ;
Pundziute, Gabija ;
Weustink, Annick C. ;
de Vos, Alexander M. ;
Pugliese, Francesca ;
Rensing, Benno ;
Jukema, J. Wouter ;
Bax, Jeroen J. ;
Prokop, Mathias ;
Doevendans, Pieter A. ;
Hunink, Myriam G. M. ;
Krestin, Gabriel P. ;
de Feyter, Pim J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (25) :2135-2144