Complications and treatment of migrated biliary endoprostheses: A review of the literature

被引:61
作者
Namdar, Thomas
Raffel, Andreas Martin
Topp, Stefan Andreas
Namdar, Lisa
Alldinger, Ingo
Schmitt, Marcus
Knoefel, Wolfram Trudo
Eisenberger, Claus Ferdinand
机构
[1] Univ Dusseldorf, Dept Gen Visceral & Pediat Surg, D-40225 Dusseldorf, Germany
[2] Univ Dusseldorf, Dept Gastroenterol Hepatol & Infectiol, D-40225 Dusseldorf, Germany
关键词
biliary endoprostheses; migrated biliary stent; colonic perforation; biliary stent complications;
D O I
10.3748/wjg.v13.i40.5397
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Endoscopic biliary stent insertion is a well-established procedure. It is especially successful in treating postoperative biliary leaks, and may prevent surgical intervention. A routine change of endoprostheses after 3 mo is a common practice but this can be prolonged to 6 mo. We reported a colonic perforation due to biliary stent dislocation and migration to the rectosigmoid colon, and reviewed the literature. (C) 2007 WJG. All rights reserved.
引用
收藏
页码:5397 / 5399
页数:3
相关论文
共 40 条
[1]  
Agarwal Naresh, 2006, Hepatobiliary Pancreat Dis Int, V5, P273
[2]   Sigmoid colonic perforation and pelvic abscess complicating biliary stent migration [J].
Anderson, Ewan Mark ;
Phillips-Hughes, Jane ;
Chapman, Roger .
ABDOMINAL IMAGING, 2007, 32 (03) :317-319
[3]   Duodenoscrotal fistula secondary to retroperitoneal migration of an endoscopically placed plastic biliary stent [J].
Basile, A ;
Macri', A ;
Lamberto, S ;
Caloggero, S ;
Versaci, A ;
Famulari, C .
GASTROINTESTINAL ENDOSCOPY, 2003, 57 (01) :136-138
[4]   Sigmoid diverticular perforation relating to the migration of a polyethylene endoprosthesis [J].
Baty, V ;
Denis, B ;
Bigard, MA ;
Gaucher, P .
ENDOSCOPY, 1996, 28 (09) :781-781
[5]  
BINMOELLER KF, 1991, AM J GASTROENTEROL, V86, P227
[6]  
Blake Anna-Maria, 2004, JSLS, V8, P73
[7]  
BUI BT, 1995, CARDIOVASC INTER RAD, V18, P200
[8]   Long-term results of endoscopic management of postoperative bile duct strictures with increasing numbers of stents [J].
Costamagna, G ;
Pandolfi, M ;
Mutignani, M ;
Spada, C ;
Perri, V .
GASTROINTESTINAL ENDOSCOPY, 2001, 54 (02) :162-168
[9]   Biliary strictures in liver transplant recipients: Treatment with metal stents [J].
Culp, WC ;
McCowan, TC ;
Lieberman, RP ;
Goertzen, TC ;
LeVeen, RF ;
Heffron, TG .
RADIOLOGY, 1996, 199 (02) :339-346
[10]   INTESTINAL PERFORATION - AN UNUSUAL COMPLICATION OF ENDOSCOPIC BILIARY STENTING [J].
DCOSTA, H ;
TOY, E ;
DENNIS, MJS ;
BROWN, C .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (804) :1270-1271