Artificial heart valves, flow acceleration and shear stresses

被引:0
|
作者
Sakhaeimanesh, Ali A. [1 ]
机构
[1] Univ Isfahan, Biomed Engn Grp, Fac Engn, Esfahan, Iran
关键词
pulsatile flow; turbulent shear stress; St. Vincent valve; flow acceleration; steady flow;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the reviewed literature, it was found that estimated turbulent shear stresses under pulsatile flow were higher than those found under steady flow conditions for the same valve. To find the possible cause of the flow acceleration on elevating turbulent shear stresses, mechanical energy (sum of kinetic and pressure energies) differences across the St. Vincent valve were calculated under both pulsatile and steady flow conditions at the same flow rate and compared. An Eulerian approach, which is preferred in fluid mechanics, was used to find temporal flow acceleration in the St. Vincent valve. Two sample windows of 10 ms were selected during the acceleration and deceleration phases of the St. Vincent valve where instantaneous flow rates were 15 or 26 l/m in (at cardiac outputs of 4, 5.5 and 7 l/min). These two instantaneous flow rates were identical to the flow rates established in steady flow investigation. Using the energy equations, kinetic and pressure energy differences across the valve in the pulsatile flow and steady flow and the difference were calculated. It was found that the energy of the flow due to the flow acceleration was: H(acc-dec(viscous-dissipation)-at 26l/min) = H(Pulsatile-acc-dec)-H(steady) = 3.655 Watts Due to the fact that size and shape of the valve, blood analogue fluid, shape and size of valve chambers and Reynolds numbers were the same in both steady and pulsatile flow investigations (for the instantaneous flow rate identical to that of steady flow), the differences between mechanical energies of the pulsatile flow and of the steady flow, H(acc-dec(viscous-dissipation)), into thermal as viscous dissipation.
引用
收藏
页码:170 / 173
页数:4
相关论文
共 50 条
  • [31] PARTICLE IMAGE VELOCIMETRY IN THE INVESTIGATION OF FLOW PAST ARTIFICIAL-HEART VALVES
    LIM, WL
    CHEW, YT
    CHEW, TC
    LOW, HT
    ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (03) : 307 - 318
  • [32] THE EVOLUTION OF ARTIFICIAL-HEART VALVES
    COLLINS, JJ
    NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (09): : 624 - 626
  • [33] ANAEMIA WITH ARTIFICIAL HEART-VALVES
    DONNELLY, RJ
    RAHMAN, AN
    MANOHITHARAJAH, SM
    WATSON, DA
    LANCET, 1972, 2 (7771): : 283 - +
  • [34] DESIGN CRITERIA FOR ARTIFICIAL HEART VALVES
    AKUTSU, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1970, 60 (01): : 34 - &
  • [35] PHYSIOLOGICAL EFFECTS OF ARTIFICIAL HEART VALVES
    GOLLAN, F
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1956, 2 : 71 - &
  • [36] Hydrodynamics of Modern Artificial Heart Valves
    S. I. Korchagin
    E. I. Kuznetsova
    A. M. Omelyanchuk
    V. N. Yurechko
    Fluid Dynamics, 2002, 37 : 101 - 108
  • [37] Detecting fractures in artificial heart valves
    Lepelaars, ESAM
    vanOoijen, WDR
    Tijhuis, AG
    deMol, BAJM
    IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM 1997, VOLS 1-4, 1997, : 1198 - 1201
  • [38] POLYURETHANE ARTIFICIAL HEART VALVES IN ANIMALS
    AKUTSU, T
    DREYER, B
    KOLFF, WJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (06) : 1045 - 1048
  • [39] ANEMIA WITH ARTIFICIAL HEART-VALVES
    不详
    LANCET, 1972, 1 (7764): : 1321 - +
  • [40] PRESENT STATUS WITH ARTIFICIAL HEART VALVES
    DALICHAU, H
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1973, 334 : 875 - 885