THE EFFECT OF ENDODONTIC ACCESS PREPARATION ON THE FAILURE LOAD OF LITHIUM DISILICATE GLASS-CERAMIC RESTORATIONS

被引:18
作者
Qeblawi, Dana [1 ]
Hill, Thomas [2 ]
Chlosta, Kelly
机构
[1] SUNY Buffalo, Dept Restorat Dent, Sch Dent Med, Buffalo, NY 14260 USA
[2] Ivoclar Vivadent Inc, Res & Dev, Sci Serv, Amherst, NY USA
关键词
FRACTURE; STRENGTH; RESIN;
D O I
10.1016/S0022-3913(11)60139-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Endodontic access preparation through lithium disilicate ceramic restorations may damage the restoration and compromise its load-bearing capability. Purpose. The purpose of this in vitro research was to investigate the effect of simulated endodontic access preparation through lithium disilicate glass-ceramic restorations on their load to failure. Material and methods. Sixty lithium disilicate glass-ceramic (IPS e.max CAD) complete-coverage restorations were milled and crystallized. Five coats of die relief were applied internally in the crown to provide a cement space approximately 60 mu m in thickness. Composite resin dies were fabricated by backfilling each crown. The specimens were then stored at 37 degrees C and 100% humidity for 30 days. The crowns with their respective dies were divided into 6 groups: Groups M-C, M-ZR, M-SC, and M-CRF were adhesively bonded with a resin cement (Multilink Implant), and Groups F-C and F-ZR were conventionally cemented with zinc phosphate cement (Fleck's). After storing all groups for 1 week, Groups M-C and F-C served as the intact controls for the 2 cementation techniques, while Groups M-ZR and F-ZR had an access prepared with a 126 mu m grit-size diamond rotary instrument. For Groups M-SC and M-CRF, the endodontic access was prepared with 150 mu m and 180 mu m grit-size diamond rotary instruments, respectively. Access preparations were restored with composite resin. All specimens were stored at 37 degrees C and 100% humidity for 1 week before they were loaded to failure with a universal loading apparatus (crosshead speed=1mm/min). The results were analyzed with a 1-way ANOVA followed by Tukey's HSD test (alpha=.05). Results. The highest failure loads were achieved with Groups M-C (3316 N +/-483) and M-ZR (3464 N +/-645) Larger grit rotary instruments resulted in lower failure-loads in Groups M-SC (2915 N +/-569) and M-CRF (2354 N +/-476). Groups F-C (2242 N +/-369) and F-ZR(1998 N +/-448) had significantly lower failure loads than their adhesively bonded counterparts (P<.05). The use of 126 mu m grit size did not significantly alter the failure loads of the restorations in either cementation technique. Conclusions. Adhesively bonded restorations sustained significantly higher loads to failure than those conventionally cemented. The use of a high efficiency, smaller-grit diamond rotary instrument for endodontic access preparation did not alter the load to failure of lithium disilicate restorations, regardless of the cement used. The use of a larger-grit rotary instrument did not improve the cutting efficiency and reduced the failure load of bonded restorations. (J Prosthet Dent 2011;106:328-336)
引用
收藏
页码:328 / 336
页数:9
相关论文
共 50 条
  • [31] Three-dimensional characterization and distribution of fabrication defects in bilayered lithium disilicate glass-ceramic molar crowns
    Jian, Yutao
    He, Zi-hua
    Dao, Li
    Swain, Michael V.
    Zhang, Xin-ping
    Zhao, Ke
    [J]. DENTAL MATERIALS, 2017, 33 (04) : E178 - E185
  • [32] One-step ceramic primer as surface conditioner: Effect on the load-bearing capacity under fatigue of bonded lithium disilicate ceramic simplified restorations
    Dapieve, Kiara Serafini
    Machry, Renan Vaz
    Pilecco, Rafaela Oliveira
    Kleverlaan, Cornelis Johannes
    Rocha Pereira, Gabriel Kalil
    Venturini, Andressa Bonin
    Valandro, Luiz Felipe
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 104
  • [33] Improving shear bond strength between feldspathic porcelain and zirconia substructure with lithium disilicate glass-ceramic liner
    Wattanasirmkit, Kamolporn
    Srimaneepong, Viritpon
    Kanchanatawewat, Kanchana
    Monmaturapoj, Naruporn
    Thunyakitpisal, Pasutha
    Jinawath, Supatra
    [J]. DENTAL MATERIALS JOURNAL, 2015, 34 (03) : 302 - 309
  • [34] Is adhesive bonding with high and low viscosity cements able to revert the negative effect of machining on the fatigue behavior of lithium disilicate glass-ceramic?
    May, Michele Mirian
    Machry, Renan Vaz
    Fraga, Sara
    de Andrade, Guilherme Schmitt
    Bottino, Marco Anto nio
    Valandro, Luiz Felipe
    May, Liliana Gressler
    [J]. INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2024, 130
  • [35] Fracture Load of Layered Glass-Ceramic Structures
    Marocho, S. M. Salazar
    Cesar, P. F.
    Griggs, J. A.
    Bottino, M. A.
    [J]. STRENGTH OF MATERIALS, 2022, 54 (03) : 515 - 524
  • [36] EFFECT OF ABUTMENT TOOTH COLOR, CEMENT COLOR, AND CERAMIC THICKNESS ON THE RESULTING OPTICAL COLOR OF A CAD/CAM GLASS-CERAMIC LITHIUM DISILICATE-REINFORCED CROWN
    Chaiyabutr, Yada
    Kois, John C.
    LeBeau, Dene
    Nunokawa, Gary
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (02) : 83 - 90
  • [37] Cement layer thickness and load-bearing capacity of tooth restored with lithium-disilicate glass ceramic and hybrid ceramic occlusal veneers
    Yli-Urpo, Topias
    Lassila, Lippo
    Narhi, Timo
    Vallittu, Pekka
    [J]. DENTAL MATERIALS, 2025, 41 (02) : 212 - 219
  • [38] Biomimetic Capabilities of Lithium Disilicate Glass-Ceramic Restorations on Posterior Teeth: Evaluation of the Long-Term Survival Rate-A 10-Year Follow-Up
    Gusiyska, Angela
    Dimova-Gabrovska, Mariana
    Nikolova, Nikoleta
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (21):
  • [39] Innovative surface treatments for improved ceramic bonding: Lithium disilicate glass ceramic
    Septimio Lanza, Marcos Daniel
    Souza Rodrigues Lanza, Flavia Juliani
    Manso, Adriana Pigozzo
    Matinlinna, Jukka Pekka
    Carvalho, Ricardo Marins
    [J]. INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2018, 82 : 60 - 66
  • [40] Composite Cement Components Stabilize the Bond ;e between a Lithium-Disilicate Glass-Ceramic and the E'sseniTitanium Abutment
    Sung, Han-Gyul
    Ko, Kyung-Ho
    Park, Chan-Jin
    Cho, Lee-Ra
    Huh, Yoon-Hyuk
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2021, 23 (05) : 469 - 475