Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet's stripping automated endothelial keratoplasty

被引:18
作者
Tomida, Daisuke [1 ]
Yamaguchi, Takefumi [1 ,2 ]
Ogawa, Akiko [1 ,2 ]
Hirayama, Yumiko [1 ]
Shimazaki-Den, Seika [1 ]
Satake, Yoshiyuki [1 ]
Shimazaki, Jun [1 ,2 ]
机构
[1] Ichikawa Gen Hosp, Tokyo Dent Coll, Dept Ophthalmol, Ichikawa, Chiba 2728513, Japan
[2] Keio Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
关键词
Endothelial keratoplasty; Femtosecond laser; Higher order aberration; Anterior segment imaging; PENETRATING KERATOPLASTY; SURFACE IRREGULARITY; MICROKERATOME; ABERRATIONS; ANTERIOR; VISION; OUTCOMES; EYES;
D O I
10.1007/s10384-015-0388-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare short-term outcomes of Descemet's stripping automated endothelial keratoplasty (DSAEK) using a graft prepared with either a femtosecond laser or a microkeratome. Methods Thirty-eight patients underwent DSAEK with grafts prepared with either a femtosecond laser (f-DSAEK; 21 eyes) or a microkeratome (m-DSAEK; 17 eyes). Visual acuity, endothelial cell density, regular astigmatism and irregular astigmatism were compared between the two groups preoperatively and at 1, 3, and 6 months post- operatively. Fourier analysis was conducted to calculate astigmatism of the anterior and posterior surfaces, and total cornea, using anterior segment optical coherence tomography (AS-OCT). Results Visual acuity (logMAR) improved from 1.20 +/- 0.60 to 0.43 +/- 0.25 after m-DSAEK (P < 0.001) and from 1.20 +/- 0.57 to 0.77 +/- 0.33 after f-DSAEK (P = 0.0028) at 6 months following DSAEK. Visual acuity after m-DSAEK was significantly better than after f-DSAEK at 1, 3, and 6 months (P < 0.05). AS-OCT corneal images revealed greater irregularities on the posterior surfaces of f-DSAEK grafts compared to m-DSAEK grafts. Irregular astigmatism of the total cornea and the posterior surface was significantly larger after f-DSAEK than after m-DSAEK, although there was no significant difference in irregular astigmatism of the anterior surface at 6 months. Postoperative visual acuity was significantly correlated with the postoperative irregular astigmatism of the total cornea (r = 0.6657 and P < 0.001) and the anterior (r = 0.416, P = 0.016) and posterior surfaces (r = 0.7046, P < 0.001). Conclusions Visual outcomes after f-DSAEK were poor compared to conventional m-DSAEK due to an increase in irregular astigmatism caused by posterior surface irregularities.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 32 条
[1]   Long-Term Results of Femtosecond Laser-Assisted Sutureless Anterior Lamellar Keratoplasty [J].
Abou Shousha, Mohamed ;
Yoo, Sonia H. ;
Kymionis, George D. ;
Ide, Takeshi ;
Feuer, William ;
Karp, Carol L. ;
O'Brien, Terrence P. ;
Culbertson, William W. ;
Alfonso, Eduardo .
OPHTHALMOLOGY, 2011, 118 (02) :315-323
[2]   Preliminary results of femtosecond laser-assisted descemet stripping endothelial keratoplasty [J].
Cheng, Yanny Y. Y. ;
Hendrikse, Fred ;
Pels, Elisabeth ;
Wijdh, Robert-Jan ;
van Cleynenbreugel, Hugo ;
Eggink, Cathariena A. ;
van Rij, Gabriel ;
Rijneveld, Wilhelmina J. ;
Nuijts, Rudy M. M. A. .
ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (10) :1351-1356
[3]   Quality of Vision After Femtosecond Laser-Assisted Descemet Stripping Endothelial Keratoplasty and Penetrating Keratoplasty: A Randomized, Multicenter Clinical Trial [J].
Cheng, Yanny Y. Y. ;
van den Berg, Tom J. T. P. ;
Schouten, Jan S. ;
Pels, Elisabeth ;
Wijdh, Robert-Jan ;
van Cleynenbreugel, Hugo ;
Eggink, Catharina A. ;
Rijneveld, Wilhelmina J. ;
Nuijts, Rudy M. M. A. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (04) :556-566
[4]   Endothelial keratoplasty: DSEK/DSAEK or DMEK - the thinner the better? [J].
Dapena, Isabel ;
Ham, Lisanne ;
Melles, Gerrit R. J. .
CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (04) :299-307
[5]   Effects of Graft Thickness and Asymmetry on Visual Gain and Aberrations After Descemet Stripping Automated Endothelial Keratoplasty [J].
Dickman, Mor M. ;
Cheng, Yanny Y. Y. ;
Berendschot, Tos T. J. M. ;
van den Biggelaar, Frank J. H. M. ;
Nuijts, Rudy M. M. A. .
JAMA OPHTHALMOLOGY, 2013, 131 (06) :737-744
[6]  
Dubbelman M., 2007, J Vis, V7, P1, DOI DOI 10.1167/707010
[7]   Penetrating keratoplasty using femtosecond laser-enabled keratoplasty with zig-zag incisions versus a mechanical trephine in patients with keratoconus [J].
Gaster, Ronald N. ;
Dumitrascu, Oanna ;
Rabinowitz, Yaron S. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (09) :1195-1199
[8]   Descemet-stripping automated endothelial keratoplasty [J].
Gorovoy, Mark S. .
CORNEA, 2006, 25 (08) :886-889
[9]   Descemet Stripping Automated Endothelial Keratoplasty for Bullous Keratopathy With an Irregular Posterior Surface [J].
Hayashi, Takahiko ;
Hirayama, Yumiko ;
Yamada, Norihiro ;
Shimazaki-Den, Seika ;
Shimazaki, Jun .
CORNEA, 2013, 32 (09) :1183-1188
[10]   Visual outcome and histological findings following femtosecond laser-assisted versus microkeratome-assisted DSAEK [J].
Heinzelmann, S. ;
Maier, P. ;
Boehringer, D. ;
Auw-Haedrich, C. ;
Reinhard, T. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (08) :1979-1985