Precise determination of permanent magnet synchronous motor parameters based on parameter identification technique

被引:0
作者
Sun, LL [1 ]
Li, HM [1 ]
Xu, BQ [1 ]
机构
[1] N China Elect Power Univ, Dept Elect Engn, Bao Ding 071003, He Bei, Peoples R China
来源
ICEMS 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1 AND 2 | 2003年
关键词
PMSM; parameter; identification; mathematical model; direct current attenuation experiment;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The precise determination of permanent magnet synchronous motors (PMSM) parameters is of great significance. By means of PMSM d, q-axis mathematical model and direct current attenuation experiment, a parameter identification technique based method to determine PMSM parameters precisely, is presented in this paper, whose effectiveness is demonstrated by the determined parameters of a 7.5kW NdFeB PMSM, which are valid and rigorous.
引用
收藏
页码:34 / 36
页数:3
相关论文
共 5 条
[2]   A NEW ALGORITHM FOR SENSORLESS OPERATION OF PERMANENT-MAGNET MOTORS [J].
ERTUGRUL, N ;
ACARNLEY, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (01) :126-133
[3]  
GARCIA G, 1999, IEE P-ELECT POW APPL, V46, P282
[4]   Detection of broken bars in induction motors using an extended Kalman filter for rotor resistance sensorless estimation [J].
Saïd, MSN ;
Benbouzid, MEH ;
Benchaib, A .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2000, 15 (01) :66-70
[5]   AN EXTENDED KALMAN FILTER APPROACH TO ROTOR TIME CONSTANT MEASUREMENT IN PWM INDUCTION-MOTOR DRIVES [J].
ZAI, LC ;
DEMARCO, CL ;
LIPO, TA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (01) :96-104