An Electrochemical Nanosensor Based on Molecularly Imprinted Polymer (MIP) for Detection of Gallic Acid in Fruit Juices

被引:53
|
作者
Shojaei, Shahrzad [1 ]
Nasirizadeh, Navid [1 ,2 ]
Entezam, Mehdi [3 ]
Koosha, Mojtaba [4 ]
Azimzadeh, Mostafa [2 ]
机构
[1] Islamic Azad Univ, Yazd Branch, Dept Text & Polymer Engn, POB 89195-155, Yazd, Iran
[2] Islamic Azad Univ, Yazd Branch, Young Researchers & Elite Club, Yazd, Iran
[3] Yazd Univ, Sch Tech & Engn, Dept Polymer Chem Engn, POB 89195-741, Yazd, Iran
[4] Shahid Beheshti Univ, Zirab Rachis, Fac Engn, Dept Pulp & Paper Energy & New Technol, Mazandaran, Iran
关键词
Molecularly imprinted polymer; MIP; Nanosensor; Gallic acid; Central composite design; SOLID-PHASE EXTRACTION; SENSITIVE DETERMINATION; SELECTIVE DETERMINATION; LIQUID-CHROMATOGRAPHY; ANTIOXIDANT CAPACITY; SENSOR; ELECTRODE; SAMPLES; QUANTIFICATION; NANOPARTICLES;
D O I
10.1007/s12161-016-0459-9
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The molecularly imprinted polymer (MIP)-based electrochemical sensor has been attending recently, due to their exceptional advantages and specificity. Here, we successfully designed and fabricated a novel electrochemical nanosensor for determination of gallic acid (GA) based on its specific MIP. The MIP was synthesized using precipitation polymerization technique, via polymerization of methacrylic acid as a functional monomer. The MIP was applied in the multiwalled carbon nanotube-modified carbon paste electrode (MWCNT-CPE), and similarly, MIP and MWCNT-modified CPE (MIP-MWCNT-CPE) was prepared, which acted as the selective recognition element and pre-concentrator agent for GA. The effect of different factors such as quantity of MIP and MWCNT, GA solution pH, and GA accumulation time on an oxidation current of accumulated GA at the electrode were investigated and optimized by central composite design (CCD) as a an experimental design and response surface methodology. The results showed that fabricated nanosensors (MIP-MWCNT-CPE) have higher sensitivity compared with bare CPE, MWCNT-CPE, and MIP-CPE. This sensor showed a linear response range of 0.12-380.0 mu M and detection limit of 47.0 nM. Finally, the nanosensor was applied to determine GA in apple, pineapple, orange juices, and a commercial green tea drink as real samples with satisfactory results.
引用
收藏
页码:2721 / 2731
页数:11
相关论文
共 50 条
  • [41] Synthesis and application of poly(methacrylic acid-co-ethylene glycol dimethacrylate) as molecularly imprinted polymer in electrochemical sensor for atrazine detection
    Gonzaga, Maria Leonia da Costa
    Oliveira, Marilia de Albuquerque
    Furtado, Roselayne Ferro
    Alves, Carlucio Roberto
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2024,
  • [42] Development of an electrochemical nanosensor for the determination of gallic acid in food
    Ghaani, Masoud
    Nasirizadeh, Navid
    Ardakani, Seyed Ali Yasini
    Mehrjardi, Farzaneh Zare
    Scampicchio, Matteo
    Farris, Stefano
    ANALYTICAL METHODS, 2016, 8 (05) : 1103 - 1110
  • [43] The graphene quantum dots encased in the molecularly imprinted polymer as a new fluorescent nanosensor for the detection of biotin
    Mohammadnejad, Parizad
    Hosseini, Seyed Mohamadreza Milani
    Sohrabi, Beheshteh
    SENSORS AND ACTUATORS REPORTS, 2024, 7
  • [44] Molecularly imprinted polymer (MIP)-Based sensing for detection of explosives: Current perspectives and future applications
    Karadurmus, Leyla
    Bilge, Selva
    Sinag, Ali
    Ozkan, Sibel A.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 155
  • [45] A novel electrochemical sensor based on a molecularly imprinted polymer for the determination of epigallocatechin gallate
    Liu, Yanrui
    Zhu, Lili
    Hu, Yue
    Peng, Xinsheng
    Du, Jiangyan
    FOOD CHEMISTRY, 2017, 221 : 1128 - 1134
  • [46] Electrochemical Detection of Vascular Endothelial Growth Factor by Molecularly Imprinted Polymer
    Bozal-Palabiyik, Burcin
    Lettieri, Mariagrazia
    Uslu, Bengi
    Marrazza, Giovanna
    ELECTROANALYSIS, 2019, 31 (08) : 1475 - 1481
  • [47] An Electrochemical Sensing Platform Based on Graphene Oxide and Molecularly Imprinted Polymer Modified Electrode for Selective Detection of Amoxicillin
    Guney, Sevgi
    Arslan, Taner
    Yanik, Serhat
    Guney, Orhan
    ELECTROANALYSIS, 2021, 33 (01) : 46 - 56
  • [48] A Molecularly Imprinted Polymer (MIP)-based Biomimetic Potentiometric sensing device for the analysis of Clarithromycin
    Mahmoudi, Shirin
    Rashedi, Hamid
    Faridbod, Farnoush
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (12): : 1654 - 1667
  • [49] An integrated carbon entrapped molecularly imprinted polymer (MIP) electrode for voltammetric detection of resveratrol in wine
    Mugo, S. M.
    Edmunds, B. J.
    Berg, D. J.
    Gill, N. K.
    ANALYTICAL METHODS, 2015, 7 (21) : 9092 - 9099
  • [50] Deep-Eutectic-Solvent-Based Mesoporous Molecularly Imprinted Polymers for Purification of Gallic Acid from Camellia spp. Fruit Shells
    Shen, Dianling
    Yan, Yu
    Hu, Xiaopeng
    Zhong, Yujun
    Li, Zhiyang
    Guo, Yaping
    Xie, Lianwu
    Yuan, Deyi
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (21)