Improved Focusing Method for 3-D Imaging using Row-Column-Addressed 2-D Arrays

被引:0
作者
Bouzari, Hamed [1 ]
Engholm, Mathias [2 ]
Stuart, Matthias Bo [1 ]
Thomsen, Erik Vilain [2 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, Bldg 349, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, Dept Micro & Nanotechnol, Bldg 344, DK-2800 Lyngby, Denmark
来源
2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2017年
关键词
TRANSDUCER; DESIGN; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A row-column-addressed (RCA) 2-D array can be interpreted as two orthogonal 1-D arrays. By transmitting with row elements and receiving the echoes through column elements or vice versa, a rectilinear volume in front of the array can be beamformed. Since the transmit and receive 1-D arrays are orthogonal to each other, only one-way focusing is possible in each transmit or receive plane. For applications, where the scatterers are sparse, e.g., in micro-bubble tracking, this study suggests to multiply the envelope data received by the row elements when transmitting with columns as well as the data received by the column elements when transmitting with rows, to improve the focusing. In this way, at each point a two-way focused profile in both transmit and receive directions can be produced. This paper investigates the performance of the new focusing scheme based on simulations and phantom measurements with a PZT lambda/2-pitch 3MHz 62+62 RCA 2-D transducer probe. A synthetic aperture imaging sequence with single element transmissions at a time, is designed for imaging down to 14 cm at a volume rate of 44 Hz.
引用
收藏
页数:4
相关论文
共 13 条
[1]  
[Anonymous], 2014, DIAGNOSTIC ULTRASOUN
[2]  
Bouzari H., 2016, P IEEE ULTRASON S, P1
[3]   Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Feasibility Study [J].
Bouzari, Hamed ;
Engholm, Mathias ;
Beers, Christopher ;
Stuart, Matthias Bo ;
Nikolov, Svetoslav Ivanov ;
Thomsen, Erik Vilain ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (06) :978-988
[4]   Top Orthogonal to Bottom Electrode (TOBE) 2-D CMUT Arrays for 3-D Photoacoustic Imaging [J].
Chee, Ryan K. W. ;
Sampaleanu, Alexander ;
Rishi, Deepak ;
Zemp, Roger J. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (08) :1393-1395
[5]   Real-Time Volume Imaging Using a Crossed Electrode Array [J].
Demore, Christine E. M. ;
Joyce, Andrew W. ;
Wall, Kieran ;
Lockwood, Geoffrey R. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (06) :1252-1261
[6]   SARUS: A Synthetic Aperture Real-Time Ultrasound System [J].
Jensen, Jorgen Arendt ;
Holten-Lund, Hans ;
Nilsson, Ronnie Thorup ;
Hansen, Martin ;
Larsen, Ulrik Darling ;
Domsten, Rune Petter ;
Tomov, Borislav Gueorguiev ;
Stuart, Matthias Bo ;
Nikolov, Svetoslav Ivanov ;
Pihl, Michael Johannes ;
Du, Yigang ;
Rasmussen, Joachim Hee ;
Rasmussen, Morten Fischer .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (09) :1838-1852
[7]  
Morton CE, 2003, ULTRASON, P968
[8]   3-D Imaging Using Row-Column-Addressed Arrays With Integrated Apodization-Part I: Apodization Design and Line Element Beamforming [J].
Rasmussen, Morten Fischer ;
Christiansen, Thomas Lehrmann ;
Thomsen, Erik Vilain ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (05) :947-958
[9]  
Sampaleanu A., 2012, TOP ORTHOGONAL TO BO
[10]   A 256 x 256 2-D Array Transducer with Row-Column Addressing for 3-D Rectilinear Imaging [J].
Seo, Chi Hyung ;
Yen, Jesse T. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (04) :837-847