Flow Injection Spectrophotometric Determination of Polyhexamethylene Biguanide Hydrochloride in Contact-lens Detergents Using Anionic Dyes

被引:5
作者
Masadome, Takashi [1 ]
Oguchi, Shota [1 ]
Kobayashi, Teruyuki [1 ]
Hattori, Toshiaki [2 ]
机构
[1] Shibaura Inst Technol, Fac Engn, Dept Appl Chem, Koto Ku, Tokyo 1358548, Japan
[2] Toyohashi Univ Technol, Dept Elect & Elect Informat Engn, Toyohashi, Aichi 4418580, Japan
关键词
Spectrophotometric analysis; polyhexamethylene biguanide hydrochloride; flow injection analysis; anionic dyes; bromocresol purple; contact-lens detergents; POLY(VINYL SULFATE); TITRATION; ELECTRODE;
D O I
10.2174/1573411013666171117162909
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: A cationic polyelectrolyte, polyhexamethylene biguanide hydrochloride (PHMB), is widely used for disinfectants in personal-care products for cosmetics and toiletries. Several colloidal titration methods for the determination of PHMB are very tedious and time-consuming. A Flow Injection Analysis (FIA) is a very advantageous analytical method because of its ease of handling, high reproducibility and high sampling rate. Therefore, the development of a simple and sensitive FIA method for the determination of PHMB is required. In this paper, we report the FIA method for the determination of PHMB based on the electrostatic and hydrophobic interactions between an anionic dye, Bromocresol purple (BCP) and PHMB. Methods: The FIA manifold consists of a two-channel system which is composed of a double plunger pump equipped with a sample injector, a flow-through type spectrophotometer and a strip chart recorder. A sample solution (140 mu L) of PHMB was injected into a distilled and deionized water stream. This stream was subsequently merged with a reagent solution stream of a solution of 20 mu M BCP adjusted to pH 8.0. The absorbance of ion associate formed between BCP and PHMB was measured at 588 nm. Results: The absorption spectra of several anionic dye (10 mu M) with PHMB (50 mu M) were measured at 400-750 nm by changing pH of the solution. The wavelength at the largest change in the absorbance between the mixed PHMB solution and the reagent blank, and the change of the absorbance at the wavelength was examined. When BCP is used as the anionic dye, the largest change in the absorbance was obtained at 588 nm and the change of the absorbance at the wavelength was -0.56 at pH = 8.0. From the results, BCP was selected as the anionic dye for the FIA determination of PHMB. Under the optimal FIA conditions, a linear relationship between the peak height and concentration of PHMB was obtained in the concentration range from 2.0 to 10.0 mu M. The present FIA method was applied to the determination of PHMB in contact-lens detergents. Conclusion: A new spectrophotometric FIA method was developed for the determination of PHMB, based on electrostatic and hydrophobic interactions between PHMB and the anionic dye, BCP. Under the optimal flow conditions of the FIA system, a good linear relationship between peak heights and concentrations of PHMB in a concentration range from 2.0 to 10.0 mu M was obtained. The present FIA method uses more simpler instrumentation, and is more rapid (sample throughput: 13 samples h(-1)) than other reported methods, and has the advantages of high sensitivity and no toxic organic solvent than other analytical methods. The present method will be very useful for the determination of PHMB in commercially available contact-lens detergents and also be applied to the determination of PHMB in the sample solution, which has similar matrix to the contact-lens detergent.
引用
收藏
页码:446 / 451
页数:6
相关论文
共 14 条
[1]   Determination of chlorhexidine digluconate and polyhexamethylene biguanide in eye drops by capillary electrophoresis with contactless conductivity detection [J].
Abad-Villar, EM ;
Etter, SF ;
Thiel, MA ;
Hauser, PC .
ANALYTICA CHIMICA ACTA, 2006, 561 (1-2) :133-137
[2]   Determination of biguanide groups in polyhexamethylene biguanide hydrochloride by titrimetric methods [J].
Hattori, T ;
Nakata, Y ;
Kato, R .
ANALYTICAL SCIENCES, 2003, 19 (11) :1525-1528
[3]   pH-potentiometirc study of polyion complexes between chitosan and poly(vinyl sulfate) or dodecylbenzene sulfonate [J].
Hattori, Toshiaki ;
Katai, Kazuhito .
ANALYTICAL SCIENCES, 2008, 24 (04) :543-546
[4]   Adsorptive voltammetry of 2-(5-bromo-2-pyridyl)azo-5-[N-n-propyl-N-(3-sulfopropyl)amino]phenol on a carbon paste electrode in the presence of organic cations and polycation [J].
Hattori, Toshiaki ;
Tsurumi, Naoko ;
Kato, Ryo ;
Nakayama, Masanori .
ANALYTICAL SCIENCES, 2006, 22 (12) :1577-1580
[5]  
Kusters Markus, 2013, J Pharm Anal, V3, P408, DOI 10.1016/j.jpha.2013.02.007
[6]   Analysis of polyhexamethylene biguanide in multipurpose contact lens solutions [J].
Lucas, Anne D. ;
Gordon, Edward A. ;
Stratmeyer, Melvin E. .
TALANTA, 2009, 80 (02) :1016-1019
[7]   Flow injection spectrophotometric determination of anionic polyelectrolytes using the cationic dyes [J].
Masadome, T .
ANALYTICAL LETTERS, 2001, 34 (15) :2711-2719
[8]   Potentiometric titration of polyhexamethylene biguanide hydrochloride with potassium poly(vinyl sulfate) solution using a cationic surfactant-selective electrode [J].
Masadome, Takashi ;
Yamagishi, Yuichi ;
Takano, Masaki ;
Hattori, Toshiaki .
ANALYTICAL SCIENCES, 2008, 24 (03) :415-418
[9]   Determination of polyhexamethylene biguanide hydrochloride [J].
Masadome, Takashi ;
Hattori, Toshiaki .
REVIEWS IN ANALYTICAL CHEMISTRY, 2014, 33 (01) :49-57
[10]   Determination of Polyhexamethylene Biguanide Hydrochloride Using Photometric Colloidal Titration with Crystal Violet as a Color Indicator [J].
Masadome, Takashi ;
Miyanishi, Takaaki ;
Watanabe, Keita ;
Ueda, Hiroshi ;
Hattori, Toshiaki .
ANALYTICAL SCIENCES, 2011, 27 (08) :817-821