Skype: a tool for functional assessment in orthopaedic research

被引:50
作者
Good, Daniel W. [1 ]
Lui, Darren F. [1 ]
Leonard, Michael [1 ]
Morris, Seamus [1 ]
McElwain, John P. [1 ]
机构
[1] Adelaide & Meath Inc Natl Childrens Hosp, Dept Trauma Orthopaed Pelv & Acetabular Reconstru, Dublin 24, Ireland
关键词
LATERAL CLAVICLE FRACTURES; OXFORD SHOULDER SCORE; HOOK-PLATE; RELIABILITY; VALIDITY; FLEXION;
D O I
10.1258/jtt.2011.110814
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Skype is a free program which enables PC users to make video calls to other users with Internet access. We carried out a prospective review of all acromioclavicular joint hook plates for lateral-third clavicle fractures over a five-year period. Functional assessment with Oxford and Constant shoulder scores were carried out using Skype and compared to outpatient review using the Bland-Altman method. Of 36 patients (mean age 36 years), 33 had a computer with a video camera, all 33 had Internet access and 22 were already users of Skype. In total 29 patients were happy to take part in Skype assessment (83%). In comparison with outpatient review, there was a mean difference in the Oxford score of -0.48 (95% confidence interval -0.84, -0.12); the mean difference for the Constant score was -0.68 (95% confidence interval -1.08, -0.29). These differences were not clinically significant, confirming that Skype can be used as an alternative to goniometry in this clinical setting. A survey showed that 93% of 29 patients surveyed preferred the use of Skype for follow-up, mainly due to the convenience and cost-saving involved. The study demonstrates the potential for this new technique in providing patients with more options for follow-up.
引用
收藏
页码:94 / 98
页数:5
相关论文
共 16 条
[1]   ANALYSIS OF ROTATION ACCOMPANYING SHOULDER FLEXION [J].
BLAKELY, RL ;
PALMER, ML .
PHYSICAL THERAPY, 1984, 64 (08) :1214-1216
[2]   RELIABILITY OF GONIOMETRIC MEASUREMENTS [J].
BOONE, DC ;
AZEN, SP ;
LIN, CM ;
SPENCE, C ;
BARON, C ;
LEE, L .
PHYSICAL THERAPY, 1978, 58 (11) :1355-1360
[3]  
CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
[4]  
Cummings SM, 2001, HEALTH SERV RES, V35, P1347
[5]   The Oxford shoulder score revisited [J].
Dawson, Jill ;
Rogers, Katherine ;
Fitzpatrick, Ray ;
Carr, Andrew .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (01) :119-123
[6]   Cutting the research budget [J].
Dillner, Luisa .
BRITISH MEDICAL JOURNAL, 2010, 341
[7]   SOURCES OF GONIOMETRIC ERROR AT THE ELBOW [J].
FISH, DR ;
WINGATE, L .
PHYSICAL THERAPY, 1985, 65 (11) :1666-1670
[8]   Hook-plate fixation of unstable lateral clavicle fractures -: A report on 63 patients [J].
Flinkkila, Tapio ;
Ristiniemi, Jukka ;
Lakovaara, Martti ;
Hyvonen, Pekka ;
Leppilahti, Juhana .
ACTA ORTHOPAEDICA, 2006, 77 (04) :644-649
[9]   CLINICAL MEASUREMENT OF RANGE OF MOTION - REVIEW OF GONIOMETRY EMPHASIZING RELIABILITY AND VALIDITY [J].
GAJDOSIK, RL ;
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (12) :1867-1872
[10]   Virtual outreach: economic evaluation of joint teleconsultations for patients referred by their general practitioner for a specialist opinion [J].
Jacklin, PB ;
Roberts, JA ;
Wallace, P ;
Haines, A ;
Harrison, R ;
Barber, JA ;
Thompson, SG ;
Lewis, L ;
Currell, R ;
Parker, S ;
Wainwright, P .
BRITISH MEDICAL JOURNAL, 2003, 327 (7406) :84-88A