Corneal Epithelium Asymmetry in Children With Atopy: The Effect of Hand Dominance

被引:3
作者
Loureiro, Tomas [1 ,4 ]
Rodrigues-Barros, Sandra [1 ]
Carreira, Ana Rita [1 ]
Gouveia-Moraes, Filipe [1 ]
Carreira, Pedro [1 ]
Escada, Ana Vide [1 ]
Campos, Paul [1 ]
Machado, Ines [1 ]
Campos, Nuno [1 ]
Archer, Timothy J. [2 ]
Reinstein, Dan Z. [2 ]
Ambrosio Jr, Renato [3 ]
机构
[1] Hosp Garcia Orta, Ophthalmol Dept, Almada, Portugal
[2] London Vis Clin, London, England
[3] Fed Univ State Rio de Janeiro, Rio De Janeiro, Brazil
[4] Hosp Garcia Orta, Ophthalmol Dept, Ave Torrado Silva, P-2805267 Almada, Portugal
来源
CLINICAL OPHTHALMOLOGY | 2022年 / 16卷
关键词
eye rubbing; keratoconus; epithelial thickness; AS-OCT; pediatrics; OPTICAL COHERENCE TOMOGRAPHY; LASIK 3-DIMENSIONAL DISPLAY; THICKNESS PROFILE; RISK-FACTORS; MYOPIC LASIK; KERATOCONUS; ARTEMIS; RESOLUTION; EYE; DIAGNOSIS;
D O I
10.2147/OPTH.S375504
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effect of eye rubbing on the epithelial thickness profile in tomographically normal corneas by AS-OCT and to compare right and left eyes in right-handed children.Methods: Thirty right-handed boys (mean age 11.2 years) with ocular allergy and history of eye rubbing were evaluated using Scheimpflug (Pentacam HR, Oculus Wetzlar, Germany) and anterior segment optical coherence tomography. Epithelial thickness (ET) and full corneal thickness (CT) parameters were compared between right and left eyes with a non-parametric Mann-Whitney test. A p-value lower than 0.05 was considered for statistical significance.Results: No eyes had topometric nor tomographic criteria for keratoconus. The min-max ET was lower in right eyes (-2.8 gm vs -3.5; p = 0.02). The difference between inferior and superior (I-S) octants was lower in right eyes (1.1 gm vs 1.9 gm; p = 0.03) as a result of inferotemporal thinning. The highest ET difference was registered between nasal and temporal octants and was more pronounced in the right eyes (2 gm vs 3.1 gm; p < 0.001).Conclusion: AS-OCT analyses reveal different epithelial thickness patterns between the eyes in young atopic patients, likely eye rubbers. Inferior and temporal epithelial thickness seem to be more affected by thinning in the eye on the side of the dominant hand.
引用
收藏
页码:2453 / 2461
页数:9
相关论文
共 50 条
[1]  
Abu-Amero KK, 2011, MOL VIS, V17, P667
[2]   The Effect of Corneal Epithelium on Corneal Curvature in Patients with Keratoconus [J].
Akcay, Emine Kalkan ;
Uysal, Betul Seher ;
Sarac, Ozge ;
Ugurlu, Nagehan ;
Yulek, Fatma ;
Cagil, Nurullah ;
Aslan, Nabi .
SEMINARS IN OPHTHALMOLOGY, 2015, 30 (5-6) :364-371
[3]   Sequence analysis of the VSX1 and SOD1 genes in families with Keratoconus and a review of the literature [J].
Al-Raddadi, Huda S. ;
Al-Barry, Ma'an A. ;
Al-Harbi, Essa ;
Samman, Mohammed I. ;
Albalawi, Alia M. ;
Basit, Sulman .
JOURNAL OF TAIBAH UNIVERSITY MEDICAL SCIENCES, 2016, 11 (02) :115-120
[4]   Corneal Morphologic Characteristics in Patients With Down Syndrome [J].
Alio, Jorge L. ;
Vega-Estrada, Alfredo ;
Sanz, Pablo ;
Osman, Amr A. ;
Kamal, Ahmed M. ;
Mamoon, Amr ;
Soliman, Hany .
JAMA OPHTHALMOLOGY, 2018, 136 (09) :971-978
[5]   Violet June: The Global Keratoconus Awareness Campaign [J].
Ambrosio Jr, Renato .
OPHTHALMOLOGY AND THERAPY, 2020, 9 (03) :685-688
[6]   Multimodal imaging for refractive surgery: Quo vadis? [J].
Ambrosio, Renato, Jr. .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) :2647-2649
[7]   Scheimpflug imaging for laser refractive surgery [J].
Ambrosio, Renato, Jr. ;
Valbon, Bruno F. ;
Faria-Correia, Fernando ;
Ramos, Isaac ;
Luz, Allan .
CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (04) :310-320
[8]   Keratoconus evaluation using the Orbscan Topography System [J].
Auffarth, GU ;
Wang, L ;
Völcker, HE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (02) :222-228
[9]  
Azartash K, 2011, MOL VIS, V17, P756
[10]   Effects of eye rubbing on the levels of protease, protease activity and cytokines in tears: relevance in keratoconus [J].
Balasubramanian, Sivaraman A. ;
Pye, David C. ;
Willcox, Mark D. P. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (02) :214-218