Optimal design based on analytical solution for storage tank with inerter isolation system

被引:94
作者
Jiang, Yiyao [1 ]
Zhao, Zhipeng [1 ]
Zhang, Ruifu [1 ]
De Domenico, Dario [2 ]
Pan, Chao [3 ]
机构
[1] Tongji Univ, Dept Disaster Mitigat Struct, Shanghai 200092, Peoples R China
[2] Univ Messina, Dept Engn, I-98166 Messina, Italy
[3] Yantai Univ, Coll Civil Engn, Yantai 264005, Peoples R China
基金
中国国家自然科学基金;
关键词
Inerter system; Isolation system; Storage tank; Analytical stochastic response; Demand oriented; SEISMIC RESPONSE MITIGATION; VIBRATION; PERFORMANCE; EARTHQUAKE;
D O I
10.1016/j.soildyn.2019.105924
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
An optimal design method based on closed-form analytical solutions is proposed for a liquid storage tank with inerter isolation system. The storage tank is modeled accounting for the flexibility of the tank wall, and isolated by the inerter isolation system composed of an inerter, a damping element, and a spring element connected between the same two terminals in parallel. The stochastic response of the storage tank with inerter isolation system, in terms of sloshing height and isolation displacement, is derived in closed form under the assumption of white-noise excitation. These analytical results are then used in an extensive parametric analysis to investigate the response variation pattern with respect to changes in the parameters of inerter system. In the extremum condition that represents the most efficient parameter set of inertance-mass ratio and damping ratio for response mitigation, an optimal design method is developed by exploiting a performance-demand-oriented design philosophy. The optimal design formulae of the inerter system are derived on the basis of target sloshing height mitigation ratio in analytical form. Moreover, a series of examples are provided to verify the proposed analytical design formulae and design criterion. Based on results from response history analysis under both artificial and natural ground motion records, the design method proves to be effective to meet the desired demand of sloshing height response, while simultaneously reducing base shear force and isolation displacement. The derived analytical design formulae are practical and convenient for preliminary design purposes and substantially explain the mechanism of inerter system for vibration control of liquid storage tank.
引用
收藏
页数:10
相关论文
共 47 条
[41]  
Zhang RF, 2014, SEISMIC RESPONSE ANA
[42]   Seismic response mitigation of a wind turbine tower using a tuned parallel inerter mass system [J].
Zhang, Ruifu ;
Zhao, Zhipeng ;
Dai, Kaoshann .
ENGINEERING STRUCTURES, 2019, 180 :29-39
[43]   Influence of mechanical layout of inerter systems on seismic mitigation of storage tanks [J].
Zhang, Ruifu ;
Zhao, Zhipeng ;
Pan, Chao .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 114 :639-649
[44]   A tuned liquid inerter system for vibration control [J].
Zhao, Zhipeng ;
Zhang, Ruifu ;
Jiang, Yiyao ;
Pan, Chao .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2019, 164
[45]   A particle inerter system for structural seismic response mitigation [J].
Zhao, Zhipeng ;
Zhang, Ruifu ;
Lu, Zheng .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2019, 356 (14) :7669-7688
[46]   Optimal design of an inerter isolation system considering the soil condition [J].
Zhao, Zhipeng ;
Chen, Qingjun ;
Zhang, Ruifu ;
Pan, Chao ;
Jiang, Yiyao .
ENGINEERING STRUCTURES, 2019, 196
[47]   Seismic response mitigation of structures with a friction pendulum inerter system [J].
Zhao, Zhipeng ;
Zhang, Ruifu ;
Jiang, Yiyao ;
Pan, Chao .
ENGINEERING STRUCTURES, 2019, 193 :110-120