Transepidermal water loss measured with the Tewameter TM300 in burn scars

被引:50
作者
Gardien, Kim L. M. [1 ,2 ,3 ]
Baas, Dominique C. [2 ,3 ]
de Vet, Henrica C. W. [4 ,5 ]
Middelkoop, Esther [1 ,2 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Plast Reconstruct & Hand Surg, MOVE Res Inst, NL-1007 MB Amsterdam, Netherlands
[2] Assoc Dutch Burn Ctr, NL-1940 EA Beverwijk, Netherlands
[3] Red Cross Hosp, Burn Ctr, NL-1942 LE Beverwijk, Netherlands
[4] Vrije Univ Amsterdam Med Ctr, EMGO Inst Hlth & Care Res, NL-1007 MB Amsterdam, Netherlands
[5] Vrije Univ Amsterdam Med Ctr, Dept Epidemiol & Biostat, NL-1007 MB Amsterdam, Netherlands
关键词
Burn scar; Reliability; Scar quality; Tewameter; Transepidermal water loss; STRATUM-CORNEUM; CLOSED-CHAMBER; STANDARDIZATION; EVAPORIMETRY; RELIABILITY; PERFORMANCE; ELASTICITY; MATURATION; GUIDELINES; MANAGEMENT;
D O I
10.1016/j.burns.2016.04.018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Transepidermal water loss (TEWL) is a physiological characteristic to measure the efficiency of the skin barrier. The aim was to investigate the reliability of the Tewameter TM300 for the assessment of TEWL (g/m(2)/h) in burn scars. Also the relation between TEWL scar values and scar quality parameters was investigated. Three different study areas (scar, healthy adjacent and contralateral skin) were assessed in 55 adult patients. The intra- and inter-observer reliability were tested using the intra-class correlation coefficient (ICC) and the standard error of measurement (SEM). The inter-observer reliability for the three areas was excellent with ICC values between 0.85 and 0.94. SEM values were between 1.76 and 3.97 g/m(2)/h. Bland-Altman plots showed relatively wide LoA values for scar and healthy skin. Mean TEWL scar values were significantly higher than healthy skin (p < 0.001). Significant correlations were found between TEWL hypertrophic scar values and erythema (r = 0.60, p = 0.001) and a negative correlation for weeks after burn (r = -0.61, p = 0.001). TEWL values were significantly different between 3 and 6 months and 3 and 12 months old scars (respectively p = 0.021 and p = 0.002). To evaluate the skin barrier function over time as a measure for scar maturation, Tewameter TM300 measurements have to be performed according to strict and standardized protocols. (C) 2016 Elsevier Ltd and ISBI: All rights reserved.
引用
收藏
页码:1455 / 1462
页数:8
相关论文
共 27 条
[1]   Criteria for assessing the tools of disability outcomes research [J].
Andresen, EM .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2000, 81 (12) :S15-S20
[2]  
[Anonymous], 2011, MEASUREMENT MED PRAC, DOI [10.1017/CBO9780511996214, DOI 10.1017/CBO9780511996214.005]
[3]  
[Anonymous], 2008, HLTH MEASUREMENT SCA, DOI DOI 10.1093/ACPROF:OSO/9780199231881.001.0001
[4]  
[Anonymous], 1978, Psychometric theory
[5]   Measurement of elasticity and transepidermal water loss rate of burn scars with the Dermalab® [J].
Anthonissen, Mieke ;
Daly, Daniel ;
Fieuws, Steffen ;
Massage, Patrick ;
Van Brussel, Michel ;
Vranckx, Jan ;
Van den Kerckhove, Eric .
BURNS, 2013, 39 (03) :420-428
[6]   Reliability of subjective wound assessment [J].
Bloemen, M. C. T. ;
van Zuijlen, P. P. M. ;
Middelkoop, E. .
BURNS, 2011, 37 (04) :566-571
[7]   Comparison of closed chamber and open chamber evaporimetry [J].
Cohen, J. C. ;
Hartman, D. G. ;
Garofalo, M. J. ;
Basehoar, A. ;
Raynor, B. ;
Ashbrenner, E. ;
Akin, F. J. .
SKIN RESEARCH AND TECHNOLOGY, 2009, 15 (01) :51-54
[8]   Validation of the VapoMeter, a closed unventilated chamber system to assess transepidermal water loss vs. the open chamber Tewameter® [J].
De Paepe, K ;
Houben, E ;
Adam, R ;
Wiesemann, F ;
Rogiers, V .
SKIN RESEARCH AND TECHNOLOGY, 2005, 11 (01) :61-69
[9]   The patient and observer scar assessment scale: A reliable and feasible tool for scar evaluation [J].
Draaijers, LJ ;
Tempelman, FRH ;
Botman, YAM ;
Tuinebreijer, WE ;
Middelkoop, E ;
Kreis, RW ;
van Zuijlen, PPM .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 113 (07) :1960-1965
[10]   Skin elasticity meter or subjective evaluation in scars: a reliability assessment [J].
Draaijers, LJ ;
Botman, YAM ;
Tempelman, FRH ;
Kreis, RW ;
Middelkoop, E ;
van Zuijlen, PPM .
BURNS, 2004, 30 (02) :109-114