Closed Loop Adaptive Optics with a Laser Guide Star for Biological Light Microscopy

被引:1
作者
Saunter, Christopher D. [1 ]
Bourgenot, Cyril
Girkin, John M.
Love, Gordon D.
机构
[1] Univ Durham, Dept Phys, Durham DH1 3LE, England
来源
MEMS ADAPTIVE OPTICS VI | 2012年 / 8253卷
基金
英国工程与自然科学研究理事会;
关键词
Adaptive Optics; Microscopy; Fluorescence; Image Optimization; Guide Star; WAVE-FRONT SENSOR; ABERRATION CORRECTION; IMAGE QUALITY;
D O I
10.1117/12.909927
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on the development of a widefield microscope that achieves adaptive optics correction through the use of a wavefront sensor observing an artificial laser guide star induced within the sample. By generating this guide star at arbitrary positions and depths within the sample we allow the delivery of high-resolution images. This approach delivers much faster AO correction than image optimization techniques, and allows the use of AO with fluorescent imaging modalities without generating excessive photo-toxic damage in the sample, or inducing significant photo-bleaching in the flurophore molecules.
引用
收藏
页数:6
相关论文
共 17 条
[1]   ODD ABERRATIONS AND DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY [J].
ARTAL, P ;
MARCOS, S ;
NAVARRO, R ;
WILLIAMS, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02) :195-201
[2]   Adaptive optics wide-field microscopy using direct wavefront sensing [J].
Azucena, Oscar ;
Crest, Justin ;
Kotadia, Shaila ;
Sullivan, William ;
Tao, Xiaodong ;
Reinig, Marc ;
Gavel, Donald ;
Olivier, Scot ;
Kubby, Joel .
OPTICS LETTERS, 2011, 36 (06) :825-827
[3]  
Blokland G. V., 1986, VISION RES, V26, P485
[4]   Wave front sensor-less adaptive optics: a model-based approach using sphere packings [J].
Booth, MJ .
OPTICS EXPRESS, 2006, 14 (04) :1339-1352
[5]   Aberration correction for confocal imaging in refractive-index-mismatched media [J].
Booth, MJ ;
Neil, MAA ;
Wilson, T .
JOURNAL OF MICROSCOPY, 1998, 192 :90-98
[6]  
Cha J W, 2008, BIOMEDICAL OPTICS, pBMD52
[7]   Effects of retinal scattering in the ocular double-pass process [J].
Diaz-Santana, L ;
Dainty, JC .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (07) :1437-1444
[8]   The use of image quality metrics for correction of non-common path errors in the ELECTRA adaptive optics system [J].
Doble, N ;
Love, G ;
Buscher, DF ;
Myers, RM ;
Purvis, A .
18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST, 1999, 3749 :785-786
[9]   Adaptive optics for deeper imaging of biological samples [J].
Girkin, John M. ;
Poland, Simon ;
Wright, Amanda J. .
CURRENT OPINION IN BIOTECHNOLOGY, 2009, 20 (01) :106-110
[10]  
Jacques SL, 2000, LASER SURG MED, V26, P119, DOI 10.1002/(SICI)1096-9101(2000)26:2<119::AID-LSM3>3.0.CO