摘要
Background: Limited data exist regarding diabetes technology use among adults with type 1 diabetes (T1D) in urban racially/ethnically diverse safety-net hospitals. We examined racial/ethnic differences in the use of continuous glucose monitor (CGM) and continuous subcutaneous insulin infusion (CSII) in this setting. Methods: A retrospective review of 227 patients >= 18 years of age with T1D seen in an urban, safety-net endocrinology clinic during 2016-2017 was completed (mean age: 39; 80% English-speaking; 50% had public insurance). Diabetes technology use, defined as either CGM or CSII or both CGM and CSII, and clinical outcomes were examined by race/ethnicity. Results: Overall, 30% used CGM and 26% used CSII. After adjusting for age, language, insurance, and annual income, diabetes technology use in non-White patients was significantly lower than in White patients, predominantly lower in Black (aOR 0.25 [95% CI 0.11-0.56]) and patients identified as other race/ethnicity (aOR 0.30 [95% CI 0.11-0.77]). At the highest household income level (>=$75,000/y), Black and Hispanic individuals were significantly less likely than White individuals to use diabetes technology (P < .0007). Mean hemoglobin A1c (HbA1c) was lower in patients using any diabetes technology compared with patients using no technology (P < .0001). Use of CGM and CSII together was associated with the lowest HbA1c across all racial/ethnic groups. Conclusions: Racial/ethnic disparities in diabetes technology use and glycemic control were observed even after adjusting for sociodemographic factors. Further research should explore barriers to accessing diabetes technology in non-White populations.
引用
收藏
页码:1010 / 1017
页数:8
相关论文
共 40 条
[31]   Diabetes Technology-Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline [J].
Peters, Anne L. ;
Ahmann, Andrew J. ;
Battelino, Tadej ;
Evert, Alison ;
Hirsch, Irl B. ;
Murad, M. Hassan ;
Winter, William E. ;
Wolpert, Howard .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2016, 101 (11) :3922-3937
[32]   The Impact of Continuous Glucose Monitoring on Markers of Quality of Life in Adults With Type 1 Diabetes: Further Findings From the DIAMOND Randomized Clinical Trial [J].
Polonsky, William H. ;
Hessler, Danielle ;
Ruedy, Katrina J. ;
Beck, Roy W. .
DIABETES CARE, 2017, 40 (06) :736-741
[33]   How organizations shape medical technology allocation: Insulin pumps and pediatric patients with type 1 diabetes [J].
Puckett, Cassidy ;
Wong, Jenise C. ;
Daley, Tanicia C. ;
Cossen, Kristina .
SOCIAL SCIENCE & MEDICINE, 2020, 249
[34]   Health-economic analysis of real-time continuous glucose monitoring in people with Type 1 diabetes [J].
Roze, S. ;
Saunders, R. ;
Brandt, A. -S. ;
de Portu, S. ;
Papo, N. L. ;
Jendle, J. .
DIABETIC MEDICINE, 2015, 32 (05) :618-626
[35]   Long-term Cost-Effectiveness of Dexcom G6 Real-time Continuous Glucose Monitoring Versus Self-Monitoring of Blood Glucose in Patients With Type 1 Diabetes in the UK [J].
Roze, Stephane ;
Isitt, John ;
Smith-Palmer, Jayne ;
Javanbakht, Mehdi ;
Lynch, Peter .
DIABETES CARE, 2020, 43 (10) :2411-2417
[36]   Glycemic Outcomes in Adults With T1D Are Impacted More by Continuous Glucose Monitoring Than by Insulin Delivery Method: 3 Years of Follow-Up From the COMISAIR Study [J].
Soupal, Jan ;
Petruzelkova, Lenka ;
Grunberger, George ;
Haskova, Aneta ;
Flekac, Milan ;
Matoulek, Martin ;
Mikes, Ondrej ;
Pelcl, Tomas ;
Skrha, Jan, Jr. ;
Horova, Eva ;
Skrha, Jan ;
Parkin, Christopher G. ;
Svacina, Stepan ;
Prazny, Martin .
DIABETES CARE, 2020, 43 (01) :37-43
[37]   Use of Factory-Calibrated Real-time Continuous Glucose Monitoring Improves Time in Target and HbA1c in a Multiethnic Cohort of Adolescents and Young Adults With Type 1 Diabetes: The MILLENNIALS Study [J].
Thabit, Hood ;
Prabhu, Joshi Navis ;
Mubita, Womba ;
Fullwood, Catherine ;
Azmi, Shazli ;
Urwin, Andrea ;
Doughty, Ian ;
Leelarathna, Lalantha .
DIABETES CARE, 2020, 43 (10) :2537-2543
[38]  
Tripp-Reimer T., 2001, Diabetes Spectrum, V14, P13, DOI DOI 10.2337/DIASPECT.14.1.13
[39]   Prevalence of and Disparities in Barriers to Care Experienced by Youth with Type 1 Diabetes [J].
Valenzuela, Jessica M. ;
Seid, Michael ;
Waitzfelder, Beth ;
Anderson, Andrea M. ;
Beavers, Daniel P. ;
Dabelea, Dana M. ;
Dolan, Lawrence M. ;
Imperatore, Giuseppina ;
Marcovina, Santica ;
Reynolds, Kristi ;
Yi-Frazier, Joyce ;
Mayer-Davis, Elizabeth J. .
JOURNAL OF PEDIATRICS, 2014, 164 (06) :1369-+
[40]   Racial-Ethnic Disparities in Management and Outcomes Among Children With Type 1 Diabetes [J].
Willi, Steven M. ;
Miller, Kellee M. ;
DiMeglio, Linda A. ;
Klingensmith, Georgeanna J. ;
Simmons, Jill H. ;
Tamborlane, William V. ;
Nadeau, Kristen J. ;
Kittelsrud, Julie M. ;
Huckfeldt, Peter ;
Beck, Roy W. ;
Lipman, Terri H. .
PEDIATRICS, 2015, 135 (03) :424-434