High Failure Rate of Modular Exchange With a Specific Design of a Constrained Liner in High-Risk Patients Undergoing Revision Total Hip Arthroplasty

被引:26
作者
Chalmers, Brian P. [1 ]
Arsoy, Diren [1 ]
Sierra, Rafael J. [1 ]
Lewallen, David G. [1 ]
Trousdale, Robert T. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, 200 First St SW, Rochester, MN 55905 USA
关键词
instability; dislocation; constrained liner; revision total hip arthroplasty; modular exchange; cemented liner; DUAL MOBILITY; RECURRENT DISLOCATION; PREVENT DISLOCATION; ACETABULAR LINER; OVERUSE SYNDROME; THA; COMPONENTS; DIAMETER; SHELL;
D O I
10.1016/j.arth.2016.02.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Addressing recurrent instability in patients with poor bone stock and inadequate abductor tensioning remains a challenge in revision total hip arthroplasty. One treatment method is implantation of a constrained liner. The purpose of this study was to determine clinical outcomes, redislocation rate, and revisions of a focally constrained liner in a high-risk patient cohort. Methods: Fifty-eight hips between 2008 and 2011 underwent implantation of a focally constrained liner. Nineteen were placed concurrent with acetabular component revision and 39 were placed into a well-fixed acetabular shell. Mean age was 69 years and mean number of previous ipsilateral hip surgeries was 4.2. At mean follow-up of 3.5 years, we analyzed clinical outcomes, redislocation, and revisions. Results: Mean Harris Hip Scores was 74. Fourteen hips (24%) were revised and 3 hips (5%) required reoperation at final follow-up. Eleven hips (19%) redislocated at a mean time to dislocation of 12.2 months; 31% (11 of 36 patients) that underwent modular exchange specifically for instability redislocated. Risk factors for redislocation included number of previous surgeries (P = .013), implantation of a 28 mm femoral head (hazards ratio 12.8), revision indication of instability (P = .04), and modular exchange with constrained liner implantation without acetabular shell revision (P = .01). Conclusion: Implantation of a focally constrained liner in revision total hip arthroplasty for recurrent instability has a high failure rate, especially with a modular exchange. Although concurrent acetabular revision had a lower redislocation rate, the decision to revise a well-fixed cup should be weighed with potential complications associated with cup revision. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1963 / 1969
页数:7
相关论文
共 37 条
[1]   Revision of an unstable hemiarthroplasty or anatomical total shoulder replacement using a reverse design prosthesis [J].
Abdel, M. P. ;
Hattrup, S. J. ;
Sperling, J. W. ;
Cofield, R. H. ;
Kreofsky, C. R. ;
Sanchez-Sotelo, J. .
BONE & JOINT JOURNAL, 2013, 95B (05) :668-672
[2]   Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options [J].
Alberton, GM ;
High, WA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1788-1792
[3]   Prevention and treatment of dislocation after total hip replacement using large diameter balls [J].
Amstutz, HC ;
Le Duff, MJ ;
Beaulé, PE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :108-116
[4]  
Andersen AV, 2013, ISRN ORTHOP, V2013, P629201
[5]  
Anderson M J, 1994, J Arthroplasty, V9, P17, DOI 10.1016/0883-5403(94)90133-3
[6]  
Beaule PE, 2004, J BONE JOINT SURG AM, V929
[7]   Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty [J].
Berry, DJ ;
Von Knoch, M ;
Schleck, CD ;
Harmsen, WS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (11) :2456-2463
[8]   A constrained liner cemented into a secure cementless acetabular shell [J].
Callaghan, JJ ;
Parvizi, J ;
Novak, CC ;
Bremner, B ;
Shrader, W ;
Lewallen, DG ;
Johnston, RC ;
Goetz, DD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (10) :2206-2211
[9]  
Callaghan JJ, 2001, CLIN ORTHOP RELAT R, P157
[10]   Revision for Recurrent Instability What are the Predictors of Failure? [J].
Carter, Aaron H. ;
Sheehan, Eoin C. ;
Mortazavi, S. M. Javad ;
Purtill, James J. ;
Sharkey, Peter F. ;
Parvizi, Javad .
JOURNAL OF ARTHROPLASTY, 2011, 26 (06) :46-52