Mechanical properties of cross-linked collagen meshes after human adipose derived stromal cells seeding

被引:9
作者
Ochoa, Ignacio [1 ,2 ]
Pena, Estefania [1 ,2 ]
Andreu, Enrique J.
Perez-Ilzarbe, Maitane
Robles, Jose E. [3 ]
Alcaine, Clara [1 ,2 ]
Lopez, Tania
Prosper, Felipe
Doblare, Manuel [1 ,2 ]
机构
[1] Aragon Inst Hlth Sci, Inst Salud Carlos III, Madrid, Spain
[2] Univ Zaragoza, Grp Struct Mech & Mat Modelling GEMM, Aragon Inst Engn Res, E-50009 Zaragoza, Spain
[3] Univ Navarra, Univ Navarra Clin, Dept Urol, E-31080 Pamplona, Spain
关键词
ADSC; collagen meshes; cross-linking; mechanical properties; pelvic organ prolapse; PELVIC ORGAN PROLAPSE; BIOMECHANICAL PROPERTIES; POLYPROPYLENE MESH; VAGINAL TISSUE; RECONSTRUCTION; SURGERY; EROSION; GRAFTS; REPAIR; DAMAGE;
D O I
10.1002/jbm.a.32988
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The main goal of this study was to evaluate the potential of collagen meshes derived from porcine dermis as scaffolds for repairing pelvic organ prolapses. Mechanical properties of collagen meshes with different cross-linking percentages before and after Adipose Derived Stromal Cells (ADSC) seeding were studied as well as the cell-scaffold interaction. Uniaxial tensile tests of the collagen meshes with three different cross-linking percentages (full-, partial-, and noncross-linked) were carried out along orthogonal directions. Their mechanical properties were studied with the same tests before and after seeding with human derived adipose stem cells (ADSC) after 1 and 7 days. Histological analyses were performed to determine adhesion and proliferation of ADSC. Significant differences in mechanical properties of the unseeded meshes were observed between each orthogonal direction independently of the cross-linking percentage. A better cell adhesion rate was observed in the cross-linked meshes. An increase in the mechanical properties after cell seeding was observed with a direct relation with the degree of cross-linking. All meshes analyzed showed a marked anisotropy that should be taken into account during the surgical procedure. The cross-linking treatment increased cell adhesion and the mechanical properties of the collagen meshes after seeding. These results suggest that the mechanical properties of this type of collagen mesh could be useful as scaffolds for repair of pelvic organ prolapse. (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 96A: 341-348, 2011.
引用
收藏
页码:341 / 348
页数:8
相关论文
共 32 条
[1]   A Biocompatible polysaccharide hydrogel-embedded polypropylene mesh for enhanced tissue integration in rats [J].
Abed, Aicha ;
Deval, Bruno ;
Assoul, Nabila ;
Bataille, Isabelle ;
Portes, Patrick ;
Louedec, Liliane ;
Henin, Dominique ;
Letourneur, Didier ;
Meddahi-Pelle, Anne .
TISSUE ENGINEERING PART A, 2008, 14 (04) :519-527
[2]   Tissue mechanics, animal models, and pelvic organ prolapse: A review [J].
Abramowitch, Steven D. ;
Feola, Andrew ;
Jallah, Zegbeh ;
Moalli, Pamela A. .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2009, 144 :S146-S158
[3]   Mechanical properties of polypropylene mesh used in pelvic floor repair [J].
Afonso, J. S. ;
Martins, P. A. L. S. ;
Girao, M. J. B. C. ;
Jorge, R. M. Natal ;
Ferreira, A. J. M. ;
Mascarenhas, T. ;
Fernandes, A. A. ;
Bernardes, J. ;
Baracat, E. C. ;
de Lima, G. Rodrigues ;
Patricio, B. .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2008, 19 (03) :375-380
[4]  
[Anonymous], COCHRANE DATABASE SY, DOI DOI 10.1002/14651858.CD005233.PUB2
[5]   Mesh augmentation during pelvic-floor reconstructive surgery: risks and benefits [J].
Baessler, Kaven ;
Maher, Christopher F. .
CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2006, 18 (05) :560-566
[6]   On modelling damage process in vaginal tissue [J].
Calvo, B. ;
Pena, E. ;
Martins, P. ;
Mascarenhas, T. ;
Doblare, M. ;
Natal Jorge, R. M. ;
Ferreira, A. .
JOURNAL OF BIOMECHANICS, 2009, 42 (05) :642-651
[7]   Regulation of extracellular matrix gene expression by mechanical stress [J].
Chiquet, M .
MATRIX BIOLOGY, 1999, 18 (05) :417-426
[8]   Fate of collagen-based implants used in pelvic floor surgery: A 2-year follow-up study in a rabbit model [J].
Claerhout, Filip ;
Verbist, Godelieve ;
Verbeken, Eric ;
Konstantinovic, Maja ;
De Ridder, Dirk ;
Deprest, Jan .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2008, 198 (01) :94.e1-94.e6
[9]   Mechanical properties of synthetic implants used in the repair of prolapse and urinary incontinence in women:: which is the ideal material? [J].
Cosson, M ;
Debodinance, P ;
Boukerrou, M ;
Chauvet, MP ;
Lobry, P ;
Crépin, G ;
Ego, A .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2003, 14 (03) :169-178
[10]  
Cosson M, 2003, INT UROGYNECOL J PEL, V14, P178