High Sensitivity and Wide Linearity LC-MS/MS Method for Oxylipin Quantification in Multiple Biological Samples

被引:14
|
作者
Fu, Xian [1 ]
Yin, Hou-Hua [1 ]
Wu, Ming-Jun [2 ]
He, Xin [1 ]
Jiang, Qing [1 ]
Zhang, Ling-Tong [1 ]
Liu, Jun-Yan [1 ]
机构
[1] Chongqing Med Univ, Inst Life Sci, Ctr Novel Target & Therapeut Intervent, Chongqing, Peoples R China
[2] Chongqing Med Univ, Inst Life Sci, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
biological regulators; liquid chromatography-tandem mass spectrometry; quantitative profiling; lower limits of quantitation; reduced sample; consumption; lipoxins; resolvins; plasma samples; quantitative sensitivity; linear range; FATTY-ACID; INDUCED LIPOKINE; PLASMA; METABOLITES; 12,13-DIHOME; ARACHIDONATE; EICOSANOIDS; PROMOTES; CELLS;
D O I
10.1016/j.jlr.2022.100302
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Oxylipins are important biological regulators that have received extensive research attention. Due to the extremely low concentrations, large concentration variations, and high structural similarity of many oxylipins, the quantitative analysis of oxylipins in biological samples is always a great challenge. Here, we developed a liquid chromatography-tandem mass spectrometry-based method with high sensitivity, wide linearity, and acceptable resolution for quantitative profiling of oxylipins in multiple biological samples. A total of 104 oxylipins, some with a high risk of detection crosstalk, were well separated on a 150 mm column over 20 min. The method showed high sensitivity with lower limits of quantitation for 87 oxylipins, reaching 0.05-0.5 pg. Unexpectedly, we found that the linear range for 16, 18, and 17 oxylipins reached 10,000, 20,000, and 40,000 folds, respectively. Due to the high sensitivity, while reducing sample consumption to below half the volume of previous methods, 74, 78, and 59 low-abundance oxylipins, among which some were difficult to detect like lipoxins and resolvins, were well quantified in the tested mouse plasma, mouse liver, and human plasma samples, respectively. Additionally, we determined that analytes with multifarious concentrations of over a 1,000-fold difference could be well quantified simultaneously due to the wide linearity. In conclusion, most likely due to the instrumental advancement, this method effectively improves the quantitative sensitivity and linear range over existing methods, which will facilitate and advance the study of the physiological and pathophysiological functions of oxylipins.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A simple LC-MS/MS method for the simultaneous quantification of endocannabinoids in biological samples
    Bobrich, Maria
    Schwarz, Rico
    Ramer, Robert
    Borchert, Philipp
    Hinz, Burkhard
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1161
  • [2] A LC-MS/MS Concoction: Method Development for Steroid Hormone Quantification in Biological Samples
    Wasniewski, Claire
    Sharma, Kavita
    Pradhan, Samjhana
    Pradhan, Devaleena
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2024, 64 : S543 - S543
  • [3] Sensitive LC-MS/MS Method for the Quantification of Macrocyclic GαqProtein Inhibitors in Biological Samples
    Kuschak, Markus
    Schlegel, Jonathan G.
    Schneider, Marion
    Kehraus, Stefan
    Voss, Jan H.
    Seidinger, Alexander
    Matthey, Michaela
    Wenzel, Daniela
    Fleischmann, Bernd K.
    Konig, Gabriele M.
    Mueller, Christa E.
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [4] An LC-MS/MS Method Development and Validation for the Quantification of Abametapir in Plasma Samples
    Sankar, Palakollu D. S.
    Panigrahi, Naresh
    SEPARATION SCIENCE PLUS, 2025, 8 (01):
  • [5] Determination of grayanotoxins in biological samples by LC-MS/MS
    Holstege, DM
    Puschner, B
    Le, T
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (03) : 1648 - 1651
  • [6] A validated LC-MS/MS method for the determination of homocysteic acid in biological samples
    Gurke, R.
    Schmidt, D.
    Thomas, D.
    Fleck, S. C.
    Geisslinger, G.
    Ferreiros, N.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 : 578 - 587
  • [7] Quantification of hydroxychloroquine in whole blood samples by LC-MS/MS
    Chusney, G. D.
    Lightstone, L.
    Cairns, T.
    Lee, J.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 500 - 500
  • [8] High-Sensitivity LC-MS/MS Quantification of Peptides and Proteins in Complex Biological Samples: The Impact of Enzymatic Digestion and Internal Standard Selection on Method Performance
    Bronsema, Kees J.
    Bischoff, Rainer
    van de Merbel, Nico C.
    ANALYTICAL CHEMISTRY, 2013, 85 (20) : 9528 - 9535
  • [9] Improved LC-MS/MS method for the quantification of hepcidin-25 in clinical samples
    Ioana M. Abbas
    Holger Hoffmann
    María Montes-Bayón
    Michael G. Weller
    Analytical and Bioanalytical Chemistry, 2018, 410 : 3835 - 3846
  • [10] Improved LC-MS/MS method for the quantification of hepcidin-25 in clinical samples
    Abbas, Ioana M.
    Hoffmann, Holger
    Montes-Bayon, Maria
    Weller, Michael G.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (16) : 3835 - 3846