Evaluation of methods for generating parametric (R)-[11C]PK11195 binding images

被引:31
作者
Schuiternaker, Alie
van Berckel, Bart Nm
Kropholler, Marc A.
Kloet, Reina W.
Jonker, Cees
Scheltens, Philip
Lammertsma, Adriaan A.
Boellaard, Ronald
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Nucl Med & PET Res, NL-1081 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Neurol Alzheimer Ctr, NL-1081 MB Amsterdam, Netherlands
关键词
benzodiazepine; benzodiazepine receptor subtypes; compartmental models; parametric; PET; radiotracers;
D O I
10.1038/sj.jcbfm.9600459
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Activated microglia can be visualised using (R)[C-11]PK11195 (1-[2-chlorophenyl]-N-methyl-N[1-methyl-propyl]-3-isoquinoline carboxamide) and positron emission tomography (PET). In previous studies, various methods have been used to quantify (R)-[C-11]PK11195 binding. The purpose of this study was to determine which parametric method would be best suited for quantifying (R)-[C-11]PK11195 binding at the voxel level. Dynamic (R)-[C-11]PK11195 scans with arterial blood sampling were performed in 20 healthy and 9 Alzheimer's disease subjects. Parametric images of both volume of distribution (V-d) and binding potential (BP) were obtained using Logan graphical analysis with plasma input. In addition, BP images were generated using two versions of the basis function implementation of the simplified reference tissue model, two versions of Ichise linearisations, and Logan graphical analysis with reference tissue input. Results of the parametric methods were compared with results of full compartmental analysis using nonlinear regression. Simulations were performed to assess accuracy and precision of each method. It was concluded that Logan graphical analysis with arterial input function is an accurate method for generating parametric images of Vd. Basis function methods, one of the lchise linearisations and Logan graphical analysis with reference tissue input provided reasonably accurate and precise estimates of BP. In pathological conditions with reduced flow rates or large variations in blood volume, the basis function method is preferred because it produces less bias and is more precise.
引用
收藏
页码:1603 / 1615
页数:13
相关论文
共 42 条
[1]   [11C](R)-PK11195 positron emission tomography imaging of activated microglia in vivo in Rasmussen's encephalitis [J].
Banati, RB ;
Goerres, GW ;
Myers, R ;
Gunn, RN ;
Turkheimer, FE ;
Kreutzberg, GW ;
Brooks, DJ ;
Jones, T ;
Duncan, JS .
NEUROLOGY, 1999, 53 (09) :2199-2203
[2]   The peripheral benzodiazepine binding site in the brain in multiple sclerosis -: Quantitative in vivo imaging of microglia as a measure of disease activity [J].
Banati, RB ;
Newcombe, J ;
Gunn, RN ;
Cagnin, A ;
Turkheimer, F ;
Heppner, F ;
Price, G ;
Wegner, F ;
Giovannoni, G ;
Miller, DH ;
Perkin, GD ;
Smith, T ;
Hewson, AK ;
Bydder, G ;
Kreutzberg, GW ;
Jones, T ;
Cuzner, ML ;
Myers, R .
BRAIN, 2000, 123 :2321-2337
[3]   Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET [J].
Boellaard, R ;
van Lingen, A ;
van Balen, SCM ;
Hoving, BG ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (01) :81-89
[4]   Data-driven volume of interest definition: Benefits and pitfalls [J].
Boellaard, Ronald ;
Schuitemaker, A. ;
van Berckel, B. ;
Kropholler, M. ;
Lammertsma, A. A. .
NEUROIMAGE, 2006, 31 :T63-T63
[5]  
Brix G, 1997, J NUCL MED, V38, P1614
[6]   In vivo detection of microglial activation in frontotemporal dementia [J].
Cagnin, A ;
Rossor, M ;
Sampson, EL ;
MacKinnon, T ;
Banati, RB .
ANNALS OF NEUROLOGY, 2004, 56 (06) :894-897
[7]   In vivo visualization of activated glia by [11C] (R)-PK11195-PET following herpes encephalitis reveals projected neuronal damage beyond the primary focal lesion [J].
Cagnin, A ;
Myers, R ;
Gunn, RN ;
Lawrence, AD ;
Stevens, T ;
Kreutzberg, GW ;
Jones, T ;
Banati, RB .
BRAIN, 2001, 124 :2014-2027
[8]   In-vivo measurement of activated microglia in dementia [J].
Cagnin, A ;
Brooks, DJ ;
Kennedy, AM ;
Gunn, RN ;
Myers, R ;
Turkheimer, FE ;
Jones, T ;
Banati, RB .
LANCET, 2001, 358 (9280) :461-467
[9]  
Cagnin A., 2001, PHYSL IMAGING BRAIN, P361
[10]   A comparison of recent parametric neuroreceptor mapping approaches based on measurements with the high affinity PET radioligands [11C]FLB 457 and [11C]WAY 100635 [J].
Cselenyi, Zsolt ;
Olsson, Hans ;
Halldin, Christer ;
Gulyas, Balazs ;
Farde, Lars .
NEUROIMAGE, 2006, 32 (04) :1690-1708