Correction of muscle artefacts in the EEG power spectrum

被引:28
|
作者
Gasser, T
Schuller, JC
Gasser, US
机构
[1] Univ Zurich, Dept Biostat, Inst Social & Prevent Med, CH-8006 Zurich, Switzerland
[2] Gerontopsychiat Zentrum Hegibach, Minervastr 145, CH-8029 Zurich, Switzerland
关键词
artefacts; EMG; quantitative EEG; beta band;
D O I
10.1016/j.clinph.2005.06.002
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To provide a method for correcting muscle artefacts in fast band power at EEG derivations. Methods: We define an indicator of surface EMG as power in the band 51.0-69.0 Hz ('muscle power'). This indicator is used to approximately eliminate the contribution of muscle activity on fast band power via a regression model. Results: (1) Patients show a larger proportion of muscle activity in fast band power. (2) There is a clear topographic pattern, frontal-temporal derivations being most susceptible to EMG artefacts. (3) The contribution of surface EMG can be drastically reduced by the proposed correction method. (4) Without correction, results for fast bands can be biased when e.g. comparing control and patient groups and the proposed correction method by and large eliminates this bias. Conclusions: It is advisable to correct the quantitative EEG reflecting fast activity for the extent of EMG artefacts. Significance: To render the quantitative EEG more valid as an indicator of cerebral activity. (c) 2005 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2044 / 2050
页数:7
相关论文
共 50 条
  • [1] Automated Detection and Correction of Eye Blink and Muscular Artefacts in EEG Signal for Analysis of Autism Spectrum Disorder
    Jadhav, P. N.
    Shanamugan, D.
    Chourasia, A.
    Ghole, A. R.
    Acharyya, A.
    Naik, G.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1881 - +
  • [2] Comparison of the ICA and PCA Methods in Correction of EEG Signal Artefacts
    Kaczorowska, Monika
    Plechawska-Wojcik, Malgorzata
    Tokovarov, Mikhail
    Dmytruk, Roman
    2017 10TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2017, : 262 - 267
  • [3] ELECTROENCEPHALOGRAM ELECTROOCULOGRAPHIC ARTEFACTS POWER SPECTRUM ANALYSIS
    Manoilov, Planien
    AEROSPACE RESEARCH IN BULGARIA, 2008, 22 : 142 - 150
  • [4] The Correction of Eye Blink Artefacts in the EEG: A Comparison of Two Prominent Methods
    Hoffmann, Sven
    Falkenstein, Michael
    PLOS ONE, 2008, 3 (08):
  • [5] CHANGES IN EEG POWER-DENSITY SPECTRUM DURING STATIC MUSCLE WORK
    KRAUSE, G
    ULLSPERGER, P
    BEYER, L
    GILLE, HG
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 51 (01): : 61 - 66
  • [6] FPGA implementation of filters for removing muscle artefacts from EEG signals
    Dutande, Prasad Vilas
    Nalbalwar, Sanjay L.
    Khobragade, Sanjay V.
    PROCEEDINGS OF THE 2018 SECOND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL SYSTEMS (ICICCS), 2018, : 728 - 732
  • [7] ARTEFACTS IN SILENT EEG
    TROJABORG, W
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1970, 29 (02): : 217 - +
  • [8] AN OCULAR ARTEFACTS CORRECTION METHOD FOR DISCRIMINATIVE EEG ANALYSIS BASED ON LOGISTIC REGRESSION
    Li, Xinyang
    Guan, Cuntai
    Ang, Kai Keng
    Wang, Chuanchu
    Chin, Zheng Yang
    Zhang, Haihong
    Lim, Choon Guan
    Lee, Tih Shih
    2015 23RD EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2015, : 2731 - 2735
  • [9] EEG power spectrum analysis in migraine
    Sisak, E
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1998, 30 (1-2) : 165 - 165
  • [10] Characterizing peaks in the EEG power spectrum
    Parameshwaran, Dhanya
    Thiagarajan, Tara C.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (04):