Submillisievert imaging protocol using full reconstruction and advanced patient motion correction in 320-row area detector coronary CT angiography

被引:6
作者
Kawaguchi, Yuko [1 ]
Fujimoto, Shinichiro [1 ]
Takamura, Kazuhisa [1 ]
Kato, Etsuro [1 ]
Suda, Shoko [1 ]
Matsumori, Rie [1 ]
Hiki, Makoto [1 ]
Kumamaru, Kanako K. [2 ]
Daida, Hiroyuki [1 ]
机构
[1] Juntendo Univ, Dept Cardiovasc Med, Grad Sch Med, Bunkyo Ku, 2-1-1 Hongo, Tokyo 1138421, Japan
[2] Juntendo Univ, Dept Radiol, Grad Sch Med, Tokyo, Japan
关键词
320-row area detector coronary computed tomography angiography; Full reconstruction; Advanced patient motion correction; Radiation dosing; Submillisievert; ROW COMPUTED-TOMOGRAPHY; ITERATIVE RECONSTRUCTION; DIAGNOSTIC-ACCURACY; ARTERY STENOSIS; QUALITY; FEASIBILITY; PERFORMANCE; SUBTRACTION; DISEASE;
D O I
10.1007/s10554-017-1237-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Radiation exposure remains a concern in the use of coronary CT angiography (CCTA). Full reconstruction (Full) and reconstruction using advanced patient motion correction (APMC) could obtain a lower radiation dose using low tube current scanning in a 320-row Area Detector CT (320-ADCT). The radiation dose for an imaging protocol using Full and APMC in daily practice was estimated. A total of 209 patients who underwent CCTA in 1 rotation scanning with 100 kv and adaptive iterative dose reduction 3D in 320-ADCT were enrolled. Imaging protocols were classified into 3 groups based on estimated slow filling time: (1) slow filling time >= 275 msec, Full with 30% of usual tube current (N = 43)(Full30%mA) (2) 206.3 msec <= slow filling time < 275 msec, APMC with 50% of usual tube current (N = 48)(APMC50%mA); and (3) 137.5 msec <= slow filling time < 206.3 msec, Half reconstruction with usual tube current (N = 118)(Half100%mA). Radiation dose was estimated by the effective dose. The diagnostic accuracy of CCTA was compared with that of invasive coronary angiography in 28 patients. The effective doses of Full30%mA, APMC50%mA, and Half100%mA were 0.77 +/- 0.31, 1.30 +/- 0.85, and 1.98 +/- 0.68, respectively. Of 28 patients, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in vessel-based analyses were: Full30%mA, 66.7, 82.4, 80.0, 40.0, and 93.3%; APMC50%mA, 100.0, 80.0, 83.3, 50.05, and 100.0%; and Half100%mA, 90.9, 83.0, 86.3, 78.95, and 92.9%, respectively. An imaging protocol using Full30%mA and APMC50%mA was one of the methods how radiation dose could be reduced radiation dose maintained diagnostic accuracy compared to imaging using conventional Half100%mA.
引用
收藏
页码:465 / 474
页数:10
相关论文
共 24 条
  • [1] Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease
    Budoff, Matthew J.
    Dowe, David
    Jollis, James G.
    Gitter, Michael
    Sutherland, John
    Halamert, Edward
    Scherer, Markus
    Bellinger, Raye
    Martin, Arthur
    Benton, Robert
    Delago, Augustin
    Min, James K.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) : 1724 - 1732
  • [2] Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    Einstein, Andrew J.
    Henzlova, Milena J.
    Rajagopalan, Sanjay
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03): : 317 - 323
  • [3] Cardiac CT: are we underestimating the dose? A radiation dose study utilizing the 2007 ICRP tissue weighting factors and a cardiac specific scan volume
    Gosling, O.
    Loader, R.
    Venables, P.
    Rowles, N.
    Morgan-Hughes, G.
    Roobottom, C.
    [J]. CLINICAL RADIOLOGY, 2010, 65 (12) : 1013 - 1017
  • [4] Hoe John, 2009, J Cardiovasc Comput Tomogr, V3, P257, DOI 10.1016/j.jcct.2009.05.013
  • [5] Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease
    Hou, Yang
    Ma, Yue
    Fan, Weipeng
    Wang, Yuke
    Yu, Mei
    Vembar, Mani
    Guo, Qiyong
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (01) : 3 - 11
  • [6] ICRP Publication 102, 2007, ICRP PUBL
  • [7] Accuracy of prospectively ECG-triggered very low-dose coronary dual-source CT angiography using iterative reconstruction for the detection of coronary artery stenosis: comparison with invasive catheterization
    Layritz, Christian
    Schmid, Jasmin
    Achenbach, Stephan
    Ulzheimer, Stefan
    Wuest, Wolfgang
    May, Matthias
    Ropers, Dieter
    Klinghammer, Lutz
    Daniel, Werner G.
    Pflederer, Tobias
    Lell, Michael
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (11) : 1238 - 1245
  • [8] ECG-edit function in multidetector-row computed tomography coronary arteriography for patients with arrhythmias
    Matsutani, Hideyuki
    Sano, Tomonari
    Kondo, Takeshi
    Morita, Hitomi
    Arai, Takehiro
    Sekine, Takako
    Takase, Shinichi
    Oida, Akitsugu
    Fukazawa, Hiroshi
    Suguta, Masahiko
    Kondo, Makoto
    Kodama, Takahide
    Orihara, Tadaaki
    Yamada, Norikazu
    Tsuyuki, Masaharu
    Narula, Jagat
    [J]. CIRCULATION JOURNAL, 2008, 72 (07) : 1071 - 1078
  • [9] Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography
    Meijboom, W. Bob
    Meijs, Matthijs F. L.
    Schuijf, Joanne D.
    Cramer, Maarten J.
    Mollet, Nico R.
    van Mieghem, Carlos A. G.
    Nieman, Koen
    van Werkhoven, Jacob M.
    Pundziute, Gabija
    Weustink, Annick C.
    de Vos, Alexander M.
    Pugliese, Francesca
    Rensing, Benno
    Jukema, J. Wouter
    Bax, Jeroen J.
    Prokop, Mathias
    Doevendans, Pieter A.
    Hunink, Myriam G. M.
    Krestin, Gabriel P.
    de Feyter, Pim J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (25) : 2135 - 2144
  • [10] Diagnostic Performance of Coronary Angiography by 64-Row CT
    Miller, Julie M.
    Rochitte, Carlos E.
    Dewey, Marc
    Arbab-Zadeh, Armin
    Niinuma, Hiroyuki
    Gottlieb, Ilan
    Paul, Narinder
    Clouse, Melvin E.
    Shapiro, Edward P.
    Hoe, John
    Lardo, Albert C.
    Bush, David E.
    de Roos, Albert
    Cox, Christopher
    Brinker, Jeffery
    Lima, Joao A. C.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (22) : 2324 - 2336