摘要
Purpose: To define the value of low-dose multislice CT in a clinical setting for early detection of pneumonia in neutropenic patients with fever of unknown origin. Materials and Methods: Thirty-five neutropenic patients suffering from fever of unknown origin with normal chest X-ray underwent unenhanced low-dose CT of the chest (120 kV, 10 eff. mAs, collimation 4 x 1 mm) using a multislice CT scanner. Axial und frontal slices with a thickness of 5 mm were calculated. If no pneumonia was found, standard antibiotics were given and a repeated examination was performed if fever continued. In case of pneumonia, antimycotic therapy was added and a follow-up CT was performed within one week. Regression or progression of pneumonia at follow-up served as evidence of pneumonia; lowering of fever within 48 h or inconspicuous follow-up CT was regarded as absence of pneumonia. Results: Ten of 35 patients had pneumonic infiltration, which decreased or increased on follow-up CT in 3 and 6 patients, respectively. One patient revealed leucemic infiltration by bronchoalveolar lavage. Twenty-five of 35 patients had no evidence of pneumonia. Twenty of these patients were free of fever within 48 h under antibiotics; one patient died due to his basic illness. Out of 4 patients with persisting fever, 3 patients had no pneumonia on repeated examination; one patient showed disseminated micronodular infiltration. Frontal reconstructions helped to differentiate infiltration from atelectasis in 4 patients. Sensitivity and specificity for the detection of pneumonia at the first examination were 90% and 96%, negative predictive value was 96%. Conclusion: Low-dose multislice CT should be performed in neutropenic patients having a fever of unknown origin and normal chest X-ray.
引用
收藏
页码:1424 / 1429
页数:6
相关论文
共 50 条
  • [31] LOW-DOSE CT DENOISING VIA NEURAL ARCHITECTURE SEARCH
    Lu, Zexin
    Xia, Wenjun
    Huang, Yongqiang
    Hou, Mingzheng
    Chen, Hu
    Shan, Hongming
    Zhang, Yi
    2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,
  • [32] Multiscale Wiener Filtering Method For Low-Dose CT Images
    Ke, Li
    Zhang, Rendong
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 428 - 431
  • [33] Lung Cancer Screening With Low-Dose CT in the United States
    Eberth, Jan M.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (12) : 1395 - 1402
  • [34] Structure-aware diffusion for low-dose CT imaging
    Du, Wenchao
    Cui, Huanhuan
    He, Linchao
    Chen, Hu
    Zhang, Yi
    Yang, Hongyu
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (15)
  • [35] Database-assisted low-dose CT image restoration
    Xu, Wei
    Ha, Sungsoo
    Mueller, Klaus
    MEDICAL PHYSICS, 2013, 40 (03)
  • [36] Low-dose CT: technique, reading methods and image interpretation
    Rampinelli, Cristiano
    Origgi, Daniela
    Bellomi, Massimo
    CANCER IMAGING, 2013, 12 (03): : 548 - 556
  • [37] Low-dose CT of the thorax in cancer follow-up
    Yamada, T
    Ono, S
    Tsuboi, M
    Saito, H
    Sato, A
    Matsuhashi, T
    Ishibashi, T
    Takahashi, S
    EUROPEAN JOURNAL OF RADIOLOGY, 2004, 51 (02) : 169 - 174
  • [38] Low-dose high-resolution CT of the petrous bone
    Husstedt, HW
    Prokop, M
    Dietrich, B
    Becker, H
    JOURNAL OF NEURORADIOLOGY, 2000, 27 (02) : 87 - 92
  • [39] Iterative reconstruction of low-dose CT based on differential sparse
    Lu, Siyu
    Yang, Bo
    Xiao, Ye
    Liu, Shan
    Liu, Mingzhe
    Yin, Lirong
    Zheng, Wenfeng
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [40] Local noise estimation in low-dose chest CT images
    J. Padgett
    A. M. Biancardi
    C. I. Henschke
    D. Yankelevitz
    A. P. Reeves
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 221 - 229