Low-dose multislice CT in febrile neutropenic patients

被引:5
|
作者
Wendel, F
Jenett, M
Geib, A
Hahn, D
Sandstede, J
机构
[1] Univ Wurzburg, Inst Rontgendiagnost, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Med Poliklin, D-97070 Wurzburg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2005年 / 177卷 / 10期
关键词
multidetector spiral CT; dose reduction; low-dose CT; lung disease; pneumonia;
D O I
10.1055/s-2005-858564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To define the value of low-dose multislice CT in a clinical setting for early detection of pneumonia in neutropenic patients with fever of unknown origin. Materials and Methods: Thirty-five neutropenic patients suffering from fever of unknown origin with normal chest X-ray underwent unenhanced low-dose CT of the chest (120 kV, 10 eff. mAs, collimation 4 x 1 mm) using a multislice CT scanner. Axial und frontal slices with a thickness of 5 mm were calculated. If no pneumonia was found, standard antibiotics were given and a repeated examination was performed if fever continued. In case of pneumonia, antimycotic therapy was added and a follow-up CT was performed within one week. Regression or progression of pneumonia at follow-up served as evidence of pneumonia; lowering of fever within 48 h or inconspicuous follow-up CT was regarded as absence of pneumonia. Results: Ten of 35 patients had pneumonic infiltration, which decreased or increased on follow-up CT in 3 and 6 patients, respectively. One patient revealed leucemic infiltration by bronchoalveolar lavage. Twenty-five of 35 patients had no evidence of pneumonia. Twenty of these patients were free of fever within 48 h under antibiotics; one patient died due to his basic illness. Out of 4 patients with persisting fever, 3 patients had no pneumonia on repeated examination; one patient showed disseminated micronodular infiltration. Frontal reconstructions helped to differentiate infiltration from atelectasis in 4 patients. Sensitivity and specificity for the detection of pneumonia at the first examination were 90% and 96%, negative predictive value was 96%. Conclusion: Low-dose multislice CT should be performed in neutropenic patients having a fever of unknown origin and normal chest X-ray.
引用
收藏
页码:1424 / 1429
页数:6
相关论文
共 50 条
  • [1] Low dose multislice CT in the pediatric patient
    Hojreh, A
    Kainberger, F
    Puig, S
    RADIOLOGE, 2003, 43 (12): : 1051 - 1055
  • [2] Low-dose spiral CT of the lung in the follow-up of non-malignant lung disease
    Coppenrath, E
    Mueller-Lisse, UG
    Lechel, U
    Veit, R
    Weber, C
    Banac, S
    Eibel, R
    Bitterling, H
    De Lorenzo, C
    Fischer, R
    Meindl, T
    Reiser, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04): : 522 - 528
  • [3] Deep learning for low-dose CT
    Chen, Hu
    Zhang, Yi
    Zhou, Jiliu
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [4] Low-dose dental CT.
    Rustemeyer, P
    Streubühr, U
    Hohn, HP
    Rustemeyer, R
    Eich, HT
    John-Mikolajewski, V
    Müller, RD
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (02): : 130 - 135
  • [5] Chest CT Has Higher Yield for Infection than CT Sinus in Febrile Neutropenic Patients
    Choi, Won Kyu
    D'Sa, Adam
    Holman, Joseph N.
    Javed, Samrah
    Thompson, Sarah
    Nadgir, Rohini N.
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2022, 51 (03) : 340 - 343
  • [6] Masked Autoencoders for Low-dose CT Denoising
    Wang, Dayang
    Xu, Yongshun
    Han, Shuo
    Yu, Hengyong
    2023 IEEE 20TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, ISBI, 2023,
  • [7] Quadratic Autoencoder for Low-Dose CT Denoising
    Fan, Fenglei
    Shan, Hongming
    Wang, Ge
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [8] Low-dose-Multislice-CT beim pädiatrischen Patienten
    A. Hojreh
    F. Kainberger
    S. Puig
    Der Radiologe, 2003, 43 : 1051 - 1055
  • [9] Importance of pulmonary imaging diagnostics in the management of febrile neutropenic patients
    Heussel, Claus Peter
    MYCOSES, 2011, 54 : 17 - 26
  • [10] Training a low-dose CT denoising network with only low-dose CT dataset: Comparison of DDLN and Noise2Void
    Liang, Kaichao
    Zhang, Li
    Xing, Yuxiang
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595