Automatic ultrasound technique to measure angle of progression during labor

被引:15
作者
Conversano, F. [1 ]
Peccarisi, M. [1 ]
Pisani, P. [1 ]
Di Paola, M. [1 ]
De Marco, T. [1 ]
Franchini, R. [1 ]
Greco, A. [1 ]
D'Ambrogio, G. [2 ]
Casciaro, S. [1 ]
机构
[1] Inst Clin Physiol, Natl Res Council, Lecce, Italy
[2] Hosp Santa Caterina Novella, Dept Obstet & Gynecol, Lecce, Italy
关键词
childbirth; intrapartum ultrasound; labor monitoring; medical decision support; progression angle; ultrasonic imaging; FETAL HEAD STATION; INTRAPARTUM TRANSLABIAL ULTRASOUND; TRANSPERINEAL ULTRASOUND; CERVICAL DILATATION; DIGITAL EXAMINATION; 1ST STAGE; 2ND-STAGE; MODE; PREDICTION; ENGAGEMENT;
D O I
10.1002/uog.17441
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To evaluate the accuracy and reliability of an automatic ultrasound technique for assessment of the angle of progression (AoP) during labor. Methods Thirty-nine pregnant women in the second stage of labor, with fetus in cephalic presentation, underwent conventional labor management with additional translabial sonographic examination. AoP was measured in a total of 95 acquisition sessions, both automatically by an innovative algorithm and manually by an experienced sonographer, who was blinded to the algorithm outcome. The results obtained from the manual measurement were used as the reference against which the performance of the algorithm was assessed. In order to overcome the common difficulties encountered when visualizing by sonography the pubic symphysis, the AoP was measured by considering as the symphysis landmark its centroid rather than its distal point, thereby assuring high measurement reliability and reproducibility, while maintaining objectivity and accuracy in the evaluation of progression of labor. Results There was a strong and statistically significant correlation between AoP values measured by the algorithm and the reference values (r = 0.99, P < 0.001). The high accuracy provided by the automatic method was also highlighted by the corresponding high values of the coefficient of determination (r(2) = 0.98) and the low residual errors (root mean square error = 2 degrees 27' (2.1%)). The global agreement between the two methods, assessed through Bland-Altman analysis, resulted in a negligible mean difference of 1 degrees 1' (limits of agreement, 4 degrees 29'). Conclusions The proposed automatic algorithm is a reliable technique for measurement of the AoP. Its (relative) operator-independence has the potential to reduce human errors and speed up ultrasound acquisition time, which should facilitate management of women during labor. Copyright (C) 2017 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:766 / 775
页数:10
相关论文
共 32 条
[1]  
Ahn Ki Hoon, 2014, Obstet Gynecol Sci, V57, P427, DOI 10.5468/ogs.2014.57.6.427
[2]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[3]   Anatomic relationship between the pubic symphysis and ischial spines and its clinical significance in the assessment of fetal head engagement and station during labor [J].
Barbera, A. F. ;
Imani, F. ;
Becker, T. ;
Lezotte, D. C. ;
Hobbins, J. C. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 33 (03) :320-325
[4]   A new method to assess fetal head descent in labor with transperineal ultrasound [J].
Barbera, A. F. ;
Pombar, X. ;
Perugino, G. ;
Lezotte, D. C. ;
Hobbins, J. C. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 33 (03) :313-319
[5]   Interobserver agreement in intrapartum estimation of fetal head station [J].
Buchmann, Eckhart ;
Libhaber, Elena .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2008, 101 (03) :285-289
[6]  
Casciaro S, 2012, P IEEE INT ULTR S, P2635
[7]   Automatic Evaluation of Progression Angle and Fetal Head Station through Intrapartum Echographic Monitoring [J].
Casciaro, Sergio ;
Conversano, Francesco ;
Casciaro, Ernesto ;
Soloperto, Giulia ;
Perrone, Emanuele ;
Di Renzo, Gian Carlo ;
Perrone, Antonio .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
[8]   Use of the angle of progression on ultrasonography to predict spontaneous onset of labor within 7 days [J].
Cho, Geum Joon ;
Hong, Hye-Ri ;
Seol, Hyun-Joo ;
Koo, Bo Hae ;
Hong, Soon-Cheol ;
Oh, Min-Jeong ;
Kim, Hai-Joong .
JOURNAL OF PERINATAL MEDICINE, 2015, 43 (02) :185-189
[9]   Evaluation of selected ultrasonography parameters in the second stage of labor in prediction mode of delivery [J].
Ciaciura-Jarno, Magdalena ;
Cnota, Wojciech ;
Wojtowicz, Dominik ;
Niesluchowska-Hoxha, Anna ;
Ruci, Aleksandra ;
Kierach, Rafal ;
Stepien, Aleksandra ;
Nowak, Agnieszka ;
Sodowska, Patrycja .
GINEKOLOGIA POLSKA, 2016, 87 (06) :448-453
[10]   Measuring engagement of the fetal head: validity and reproducibility of a new ultrasound technique [J].
Dietz, HP ;
Lanzarone, V .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (02) :165-168