Derivative-Hilbert-Backprojection based image reconstruction from truncated projections in helical cone-beam CT

被引:0
|
作者
Zhang Feng [1 ]
Yan Bin [1 ]
Li Lei [1 ]
Xi Xiao-Qi [1 ]
Jiang Hua [1 ]
Wei Xing [1 ]
Zhang Xiang [1 ]
Cui Jin-Xian [1 ]
机构
[1] Natl Digital Switching Syst Engn Technol Res Ctr, Zhengzhou 450002, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Helical cone-beam CT; Image reconstruction; Truncation artifacts; Derivative-Hilbert-Backprojection; COMPUTED-TOMOGRAPHY; INTERIOR TOMOGRAPHY; ALGORITHM;
D O I
10.13538/j.1001-8042/nst.26.20401
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In helical cone-beam computed tomography (CT), Feldkamp-Davis-Kress (FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection truncation. The reason is that the ramp filter is global. To restrain the truncation artifacts, an approximate reconstruction formula is proposed based on the Derivative-Hilbert-Backprojection (DHB) framework. In the method, the first order derivative filter is followed by the Hilbert transform. Since the filtered projection values are almost zero by the first order derivative filter, the following Hilbert transform has little influence on the projection values, even though the projections are laterally truncated. The proposed method has two main advantages. First, it has comparable computational efficiency and image quality as well as the conventional helical FDK algorithm for non-truncated projections. The second advantage is that images can be reconstructed with acceptable quality and much lower computational cost in comparison to the Laplace operator based algorithm in cases with truncated projections. To point out the advantages of our method, simulations on the computer and real data experiments on our laboratory industrial cone-beam CT are conducted. The simulated and experimental results demonstrate that the method is feasible for image reconstruction in the case of projection truncation.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Rebinned Filtered Back-Projection Reconstruction From Truncated Data for Half-Covered Helical Cone-Beam Computed Tomography
    Han, Yu
    Yan, Bin
    Li, Lei
    Xi, Xiaoqi
    Hu, Guoen
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (05) : 2753 - 2763
  • [32] Exact image reconstruction in a helical cone-beam scan with a variable pitch
    Zou, Y
    Pan, XC
    Xia, D
    Wang, G
    Jiang, TZ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4200 - 4203
  • [33] Image reconstruction in reduced circular sinusoidal cone-beam CT
    Xia, Dan
    Cho, Seungryong
    Pan, Xiaochuan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2009, 17 (03) : 189 - 205
  • [34] Translational motion correction algorithm for truncated cone-beam CT using opposite projections
    Gu, Jawook
    Bae, Woong
    Ye, Jong Chul
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (06) : 927 - 944
  • [35] Volume-of-Interest Reconstruction from Severely Truncated Data in Dental Cone-Beam CT
    Zhang, Zheng
    Kusnoto, Budi
    Han, Xiao
    Sidky, E. Y.
    Pan, Xiaochuan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [36] High-quality image reconstruction from exterior helical cone-beam CT data for NDE of industrial pipelines
    Guo, Jiqiang
    Zeng, Li
    Liu, Baodong
    INSIGHT, 2011, 53 (10) : 534 - 541
  • [37] Few-view cone-beam CT reconstruction with deformed prior image
    Zhang, Hua
    Ouyang, Luo
    Huang, Jing
    Ma, Jianhua
    Chen, Wufan
    Wang, Jing
    MEDICAL PHYSICS, 2014, 41 (12)
  • [38] Feldkamp-based cone-beam reconstruction for gantry-tilted helical multislice CT
    Hein, I
    Taguchi, K
    Silver, MD
    Kazama, M
    Mori, I
    MEDICAL PHYSICS, 2003, 30 (12) : 3233 - 3242
  • [39] Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm
    Lauzier, Pascal Theriault
    Tang, Jie
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09) : 2461 - 2476
  • [40] Exact local regions-of-interest reconstruction in spiral cone-beam filtered-backprojection CT: numerical implementation and first image results
    Lauritsch, G
    Tam, KC
    Sourbelle, K
    Schaller, S
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 520 - 532