Development and Validation of Reversed Phase High Performance Liquid Chromatographic Method for Determination of Amlodipine

被引:8
|
作者
Alaama, Mohamed [1 ,2 ]
Uddin, A. B. M. Helal [1 ]
Mohamad, Huda Jamilah [1 ]
Amiruddin, Noor Syafawati [1 ]
Abbas, S. A. [3 ]
机构
[1] IIUM, Fac Pharm, Dept Pharmaceut Chem, Analyt & Bioanalyt Res Lab, Kuantan 25200, Pahang, Malaysia
[2] Aleppo Univ, Fac Pharm, Dept Food & Analyt Chem, Aleppo, Syria
[3] Taylors Univ, Sch Pharm, Subang Jaya 47500, Selangor Darul, Malaysia
关键词
Amlodipine; Recovery; Repeatability; Precision; Reversed phase high performance liquid chromatography; Validation; HUMAN PLASMA; BESYLATE; ELECTROPHORESIS; FORMULATIONS; VALSARTAN; DRUG;
D O I
10.4314/tjpr.v14i4.15
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose: To develop and validate a new sensitive and low-cost method for the analysis of amlodipine in tablet dosage form using reversed phase high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detection. Methods: Standards and samples were prepared by dissolving amlodipine besylate standard or amlodipine tablets in mobile phase and sonicated for 5 min. The samples were analysed by RP-HPLC equipped with quaternary pump and auto-injector. Separation was achieved using C18 column, and the mobile phase consisted of ammonium acetate buffer containing 0.02 % triethylamine TEA (pH = 4, adjusted using glacial acetic acid) and acetonitrile in the ratio 60: 40 v/v. The flow rate was 1 ml/min and a UV detector was used for the detection of amlodipine at a wavelength of 248 nm. The method was validated according to International Conference of Harmonization (ICH) guidelines. Results: The retention time for amlodipine peak was 3.44 +/- 0.41 min with a total run time of 6 min. The method was linear over the range of 0.5 - 40 mu g/ml with coefficient of determination (R-2) of 0.999. Recovery was 98.09 - 100.19 %, and the method showed high precision and repeatability. All validated parameters were within the range of ICH requirements. Conclusion: A new rapid sensitive and low-cost method has been developed and validated for the analysis of amlodipine in tablet dosage form.
引用
收藏
页码:663 / 669
页数:7
相关论文
共 50 条
  • [41] Box-Behnken Design Based Development of UV-Reversed Phase High Performance Liquid Chromatographic Method for Determination of Ascorbic Acid in Tablet Formulations
    Azmi, Syed Najmul Hejaz
    Al Hoqani, Umaima
    Al Mamari, Juhaina Obaid Said
    Al Mamari, Buthaina Mohamed Salim
    Al Jassasi, Balaqis Sultan Ali Rashid
    Al Rubaiai, Aziza Saleh Saif
    Rahman, Nafisur
    Nasir, Mohd
    Haque, Sk Manirul
    Khan, Shah Alam
    Ahmed, Qamar Uddin
    Zakaria, Zainul Amiruddin
    SEPARATIONS, 2022, 9 (11)
  • [42] A High-Performance Liquid Chromatographic Method for the Determination of Meropenem in Serum
    Dincel, Demet
    Sagirli, Olcay
    Topcu, Gulacti
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2020, 58 (02) : 144 - 150
  • [43] Development and validation of a reversed-phase high-performance liquid chromatography method for quantification of hesperidin from a nutraceutical
    Panda, Vandana
    Pund, Swapnil
    Saindane, Akash
    Bokde, Vidya
    SEPARATION SCIENCE PLUS, 2023, 6 (10)
  • [44] Development and validation of a high performance liquid chromatographic method for the simultaneous determination of potassium clavulanate and cefadroxil in synthetically prepared tablets
    Sharif, S.
    Khan, I. U.
    Ashfaq, M.
    Iqbal, M. S.
    Ahmad, S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (10) : 1029 - 1034
  • [45] Method Development and Validation for the Simultaneous Estimation of Rosuvastatin and Amlodipine in Bulk and its Formulation using Reverse-Phase High-Performance Liquid Chromatography
    Boggula, Narender
    Mulagada, Gowri Manoja
    Priya, D. K. Shanthi
    Bakshi, Vasudha
    Peddapalli, Himabindu
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (04) : S1304 - S1309
  • [46] Development and Validation of a Simple, Precise, and Robust Reversed-Phase High-Performance Liquid Chromatography-Ultraviolet Method for the Determination of Polyvinylpyrrolidone in Adhesives
    Gupta, Anand
    Nautiyal, Kanchan
    Saxena, Anubhav
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (12) : 1834 - 1843
  • [47] Development and validation of reversed phase HPLC method for the determination of vildagliptin using an experimental design
    Kashid, A. M.
    Ghorpade, D. A.
    Toranmal, P. P.
    Dhawale, S. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (04) : 510 - 515
  • [48] Development and validation of stability indicating reversed-phase liquid chromatographic method for simultaneous quantification of methotrexate and teriflunomide in nanoparticles and marketed formulation
    Pandey, Shweta
    Mahtab, Asiya
    Singh, Archu
    Ahmad, Farhan Jalees
    Aqil, Mohd.
    Talegaonkar, Sushama
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (12)
  • [49] Simultaneous determination of related substances of telmisartan and hydrochlorothiazide in tablet dosage form by using reversed phase high performance liquid chromatographic method
    Mukhopadhyay, Sutirtho
    Kadam, Kiran
    Sawant, Laxman
    Nachane, Dhanashree
    Pandita, Nancy
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2011, 3 (03): : 375 - 383
  • [50] Development and Validation of a Stability-Indicating High Performance Liquid Chromatographic (HPLC) Method for the Determination of Related Substances of Micafungin Sodium in Drug Substances
    Zhu, Shengsheng
    Meng, Xiang
    Su, Xin
    Luo, Yongwei
    Sun, Zuyue
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2013, 14 (11): : 21202 - 21214