Development and Validation of Reversed Phase High Performance Liquid Chromatographic Method for Determination of Amlodipine

被引:8
|
作者
Alaama, Mohamed [1 ,2 ]
Uddin, A. B. M. Helal [1 ]
Mohamad, Huda Jamilah [1 ]
Amiruddin, Noor Syafawati [1 ]
Abbas, S. A. [3 ]
机构
[1] IIUM, Fac Pharm, Dept Pharmaceut Chem, Analyt & Bioanalyt Res Lab, Kuantan 25200, Pahang, Malaysia
[2] Aleppo Univ, Fac Pharm, Dept Food & Analyt Chem, Aleppo, Syria
[3] Taylors Univ, Sch Pharm, Subang Jaya 47500, Selangor Darul, Malaysia
关键词
Amlodipine; Recovery; Repeatability; Precision; Reversed phase high performance liquid chromatography; Validation; HUMAN PLASMA; BESYLATE; ELECTROPHORESIS; FORMULATIONS; VALSARTAN; DRUG;
D O I
10.4314/tjpr.v14i4.15
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose: To develop and validate a new sensitive and low-cost method for the analysis of amlodipine in tablet dosage form using reversed phase high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detection. Methods: Standards and samples were prepared by dissolving amlodipine besylate standard or amlodipine tablets in mobile phase and sonicated for 5 min. The samples were analysed by RP-HPLC equipped with quaternary pump and auto-injector. Separation was achieved using C18 column, and the mobile phase consisted of ammonium acetate buffer containing 0.02 % triethylamine TEA (pH = 4, adjusted using glacial acetic acid) and acetonitrile in the ratio 60: 40 v/v. The flow rate was 1 ml/min and a UV detector was used for the detection of amlodipine at a wavelength of 248 nm. The method was validated according to International Conference of Harmonization (ICH) guidelines. Results: The retention time for amlodipine peak was 3.44 +/- 0.41 min with a total run time of 6 min. The method was linear over the range of 0.5 - 40 mu g/ml with coefficient of determination (R-2) of 0.999. Recovery was 98.09 - 100.19 %, and the method showed high precision and repeatability. All validated parameters were within the range of ICH requirements. Conclusion: A new rapid sensitive and low-cost method has been developed and validated for the analysis of amlodipine in tablet dosage form.
引用
收藏
页码:663 / 669
页数:7
相关论文
共 50 条
  • [31] Development and validation of a new stability indicating reversed phase liquid chromatographic method for the determination of prednisolone acetate and impurities in an ophthalmic suspension
    Marley, Adrian
    Stalcup, Apryll M.
    Connolly, Damian
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 102 : 261 - 266
  • [32] Development and validation of high performance liquid chromatographic method for the analysis of divalproex sodium
    Reddy, Pasam Satyanarayana
    Jagarlapudi, V. Shanmukha Kumar
    Sekharan, Chandra Bala
    MOROCCAN JOURNAL OF CHEMISTRY, 2015, 3 (04): : 798 - 808
  • [33] Development and Validation of a High Performance Liquid Chromatographic Method for Determination of Bimatoprost in Chitosan-Based Ocular Inserts
    Franca, Jucara R.
    Batista, Luciana D.
    Ribeiro, Tatiana G.
    Fernandes, Christian
    Castilho, Rachel O.
    Faraco, Andre A. G.
    ANALYTICAL LETTERS, 2015, 48 (03) : 531 - 540
  • [34] DEVELOPMENT AND VALIDATION OF A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR DETERMINATION OF CYCLOSPORINE-A FROM BIODEGRADABLE INTRAOCULAR IMPLANTS
    Saliba, Juliana Barbosa
    Cunha Junior, Armando da Silva
    de Lima Gomes, Elionai Cassiana
    Mansur, Herman Sander
    da Silva, Gisele Rodrigues
    QUIMICA NOVA, 2011, 34 (01): : 140 - 144
  • [35] Method Development and Validation for the Determination of Caffeine: An Alkaloid from Coffea arabica by High-performance Liquid Chromatography Method
    Naveen, P.
    Lingaraju, H. B.
    Deepak, M.
    Medhini, B.
    Prasad, K. Shyam
    PHARMACOGNOSY RESEARCH, 2018, 10 (01): : 88 - 91
  • [36] Development and Validation of High-Performance Liquid Chromatographic Method for Quantitative Estimation of Glycyrrhetinic Acid in Microemulsion
    Chivate, Niranjan
    Wadkar, Kiran
    Shah, Rohit
    Chivate, Anuradha
    LATIN AMERICAN JOURNAL OF PHARMACY, 2019, 38 (05): : 1045 - 1049
  • [37] Chromatographic method development and validation for the determination of valsartan in biological fluid
    Ghayas, Sana
    Shoaib, Muhammad Harris
    Siddiqui, Fahad
    Yousuf, Rabia Ismail
    Masood, M. Ali
    Anjum, Fakhsheena
    Bushra, Rabia
    Bashir, Lubna
    Naz, Shazia
    Muhammad, Iyad Naeem
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 30 (06) : 2355 - 2362
  • [38] Development and validation of an automated solid phase extraction and liquid chromatographic method for the determination of piperaquine in urine
    Tarning, J
    Singtoroj, T
    Annerberg, A
    Ashton, M
    Bergqvist, Y
    White, NJ
    Day, NPJ
    Lindegardh, N
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (01) : 213 - 218
  • [39] Development and Validation of a High-Performance Liquid Chromatographic Method for Content Assay of Ceftriaxone in Pharmaceutical Dosage
    Hiremath, Basavaraj
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2025, 59 (01) : 94 - 100
  • [40] Development and validation of a dissolution test with reversed-phase high performance liquid chromatographic analysis for Candesartan cilexetil in tablet dosage forms
    Kamalakkannan, Vairappan
    Puratchikody, Ayarivan
    Ramanathan, Lakshmanan
    Jayapraba, Sundaravadivelu
    ARABIAN JOURNAL OF CHEMISTRY, 2016, 9 : S867 - S873