Development and Validation of Reversed Phase High Performance Liquid Chromatographic Method for Determination of Amlodipine

被引:8
|
作者
Alaama, Mohamed [1 ,2 ]
Uddin, A. B. M. Helal [1 ]
Mohamad, Huda Jamilah [1 ]
Amiruddin, Noor Syafawati [1 ]
Abbas, S. A. [3 ]
机构
[1] IIUM, Fac Pharm, Dept Pharmaceut Chem, Analyt & Bioanalyt Res Lab, Kuantan 25200, Pahang, Malaysia
[2] Aleppo Univ, Fac Pharm, Dept Food & Analyt Chem, Aleppo, Syria
[3] Taylors Univ, Sch Pharm, Subang Jaya 47500, Selangor Darul, Malaysia
关键词
Amlodipine; Recovery; Repeatability; Precision; Reversed phase high performance liquid chromatography; Validation; HUMAN PLASMA; BESYLATE; ELECTROPHORESIS; FORMULATIONS; VALSARTAN; DRUG;
D O I
10.4314/tjpr.v14i4.15
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose: To develop and validate a new sensitive and low-cost method for the analysis of amlodipine in tablet dosage form using reversed phase high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detection. Methods: Standards and samples were prepared by dissolving amlodipine besylate standard or amlodipine tablets in mobile phase and sonicated for 5 min. The samples were analysed by RP-HPLC equipped with quaternary pump and auto-injector. Separation was achieved using C18 column, and the mobile phase consisted of ammonium acetate buffer containing 0.02 % triethylamine TEA (pH = 4, adjusted using glacial acetic acid) and acetonitrile in the ratio 60: 40 v/v. The flow rate was 1 ml/min and a UV detector was used for the detection of amlodipine at a wavelength of 248 nm. The method was validated according to International Conference of Harmonization (ICH) guidelines. Results: The retention time for amlodipine peak was 3.44 +/- 0.41 min with a total run time of 6 min. The method was linear over the range of 0.5 - 40 mu g/ml with coefficient of determination (R-2) of 0.999. Recovery was 98.09 - 100.19 %, and the method showed high precision and repeatability. All validated parameters were within the range of ICH requirements. Conclusion: A new rapid sensitive and low-cost method has been developed and validated for the analysis of amlodipine in tablet dosage form.
引用
收藏
页码:663 / 669
页数:7
相关论文
共 50 条
  • [21] Development and validation of liquid chromatographic method for quantitative determination of Loxoprofen in mobile phase and in human plasma
    Farooq, Muhammad
    Shoaib, Muhammad Harris
    Yousuf, Rabia Ismail
    Siddiqui, Fahad
    Hanif, Muhammad
    Naz, Shazia
    Bashir, Lubna
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 31 (06) : 2629 - 2633
  • [22] High Performance Liquid Chromatographic Method Development and Its Validation for Salbutamol
    Muralidharan, Selvadurai
    Kumar, Jayaraj
    BRITISH JOURNAL OF PHARMACEUTICAL RESEARCH, 2012, 2 (04): : 228 - 237
  • [23] Development and validation of a high-performance liquid chromatographic method for bioanalytical application with rimonabant
    Bhaumik, Uttam
    Ghosh, Animesh
    Chatterjee, Bappaditya
    Sengupta, Pinaki
    Darbar, Soumendra
    Roy, Bikash
    Nandi, Utpal
    Pal, Tapan K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (04) : 1009 - 1013
  • [24] Development and validation of a reversed-phase high-performance liquid chromatographic method for quantification of peptide dendrimers in human skin permeation experiments
    Mutalik, S.
    Hewavitharana, A. K.
    Shaw, P. N.
    Anissimov, Y. G.
    Roberts, M. S.
    Parekh, H. S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3556 - 3562
  • [25] Development and validation of high performance liquid chromatographic method for analysis of clozapine
    Kaur, Harpreet
    Bassi, Pallavi
    Monif, Tausif
    Khuroo, Arshad
    Kaur, Gurpreet
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2013, 26 (03) : 465 - 472
  • [26] Development and Validation of a Specific Stability Indicating High Performance Liquid Chromatographic Method for Valsartan
    Rao, K. S.
    Jena, N.
    Rao, M. E. B.
    JOURNAL OF YOUNG PHARMACISTS, 2010, 2 (02) : 183 - 189
  • [27] Development and validation of a high-performance liquid chromatographic method for the determination of cyproterone acetate in human skin
    de Hassonville, SH
    Chiap, P
    Liégeois, JF
    Evrard, B
    Delattre, L
    Crommen, J
    Piel, G
    Hubert, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (01) : 133 - 143
  • [28] Development and Validation of a Reversed-Phase Ultra-Performance Liquid Chromatographic Method for the Simultaneous Determination of Six Drugs Used for Combined Hypertension Therapy
    Kaila, Harshad O.
    Ambasana, Mrunal A.
    Shah, Anamik K.
    JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (02) : 295 - 300
  • [29] Development and Validation of a Liquid Chromatographic Method for Determination of Efavirenz in Human Plasma
    A. Lakshmi Sailaja
    K. Kishore Kumar
    D. V. R. Ravi Kumar
    C. Mohan Kumar
    N. M. Yugandhar
    G. Srinubabu
    Chromatographia, 2007, 65 : 359 - 361
  • [30] Development and validation of a liquid chromatographic method for determination of efavirenz in human plasma
    Sailaja, A. Lakshmi
    Kumar, K. Kishore
    Kumar, D. V. R. Ravi
    Kumar, C. Mohan
    Yugandhar, N. M.
    Srinubabu, G.
    CHROMATOGRAPHIA, 2007, 65 (5-6) : 359 - 361