Fretting behavior of cortical bone against titanium and its alloy

被引:61
作者
Yu, HY
Cai, ZB
Zhou, ZR [1 ]
Zhu, MH
机构
[1] SW Jiaotong Univ, Key Lab Adv Technol Mat, Tribol Res Inst, Chengdu 610031, Peoples R China
[2] Sichuan Univ, W China Coll Stomatol, Chengdu 610041, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
fretting wear; cortical bone; femur; titanium; mechanism;
D O I
10.1016/j.wear.2005.01.037
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Under the lubrication by the imitated human physiological solution, the fretting behaviors of flat cortical bone were investigated against titanium (TA2) and its alloy (TC4) ball counterpart. The friction logs and coefficients were recorded automatically. The worn surfaces of cortical bone were analyzed by means of laser confocal scanning microscopy. The results show that friction logs transform from partial slip directly to gross slip without mixed regime. The wear depths of bone generally increase with the friction coefficient. The worn sear area on bone is a little bit larger than that on ball surface. The wear depths on Ti ball were only several micrometers, which were much less than those on bone. The comparison of fretting behaviors between the bone-TA2 pair and bone-TC4 pair were of particular interest. The friction coefficient of bone-TC4 pair is higher than that of bone-TA2 pairs. The maximum wear depth on bone against TA2 is about 40% the value of that on bone against TC4. The wear adaptability of bone-TA2 pair is better than that of bone-TC4 pair. The abrasive wear and delamination related to the microstructure of bone are observed on the wear sear of cortical bone. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:910 / 918
页数:9
相关论文
共 19 条
[1]  
Alam O, 2002, TRIBOL INT, V35, P357
[2]   Effect of mechanical surface pretreatment on metal ion release [J].
Browne, M ;
Gregson, PJ .
BIOMATERIALS, 2000, 21 (04) :385-392
[3]   TRIBOLOGICAL PROPERTIES OF TITANIUM-ALLOYS [J].
BUDINSKI, KG .
WEAR, 1991, 151 (02) :203-217
[4]   Effect of chromic acid anodizing treatment on fretting behaviour during fretting tests on pre-stressed specimens [J].
Degat, PR ;
Zhou, ZR ;
Vincent, L .
THIN SOLID FILMS, 1997, 298 (1-2) :170-176
[5]   Clinical complications of osseointegrated implants [J].
Goodacre, CJ ;
Kan, JYK ;
Rungcharassaeng, K .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (05) :537-552
[6]  
HOSHAW SJ, 1995, T ORTHOP RES SOC, V20, P188
[7]  
Kato K., 2001, MODERN TRIBOLOGY HDB
[8]  
Ko C C, 1992, J Oral Implantol, V18, P220
[9]   Fluorescence-aided detection of microdamage in compact bone [J].
Lee, TC ;
Myers, ER ;
Hayes, WC .
JOURNAL OF ANATOMY, 1998, 193 :179-184
[10]   Titanium alloys in total joint replacement - a materials science perspective [J].
Long, M ;
Rack, HJ .
BIOMATERIALS, 1998, 19 (18) :1621-1639