High precision biometry of pseudophakic eyes using partial coherence interferometry

被引:104
作者
Findl, O [1 ]
Drexler, W [1 ]
Menapace, R [1 ]
Hitzenberger, CK [1 ]
Fercher, AF [1 ]
机构
[1] Univ Vienna, Allgemeines Krankenhaus Wien, Klin Augenheilkunde, Vienna, Austria
关键词
D O I
10.1016/S0886-3350(98)80102-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the applicability of the scanning version of dual-beam partial coherence interferometry (PCI) for measuring the anterior segment and axial length of pseudophakic eyes in a clinical setting and to determine the achievable precision with this biometry technique. Setting: Department of Ophthalmology, Vienna General Hospital, and Institute of Medical Physics, University of Vienna, Austria. Methods: Partial coherence interferometry was performed in 39 pseudophakic eyes of 39 patients after implantation of a foldable acrylic intraocular lens (IOL). Results: Effective lens position (ELP), IOL thickness, and lens-capsule distance (LCD) were determined with a precision of 2 to 3 mu m; corneal thickness and axial eye length, with a precision of 0.8 and 5.0 mu m, respectively The mean ELF of the IOL was 4.093 mm +/- 0.290 (SD). In 7 eyes (18%), a positive LCD of 68 +/- 40 mu m was detected with PCI. Mean corneal thickness was 526.4 +/- 31.5 mu m; mean IOL thickness, 791.5 +/- 40.2 mu m; and mean axial length, 23.388 +/- 0.824 mm. Conclusion: The scanning version of PCI enables high precision (less than or equal to 5 mu m) and high resolution (similar to 12 mu m) biometry of pseudophakic eyes that is better than conventional ultrasound by a factor of more than 20. For the first time, positive LCD, a possible risk factor for posterior capsule opacification: could be detected;nd quantified. Furthermore, this technique offers a high degree of comfort for the patient since it is a noncontract method with no need for local anesthesia or pupil dilation and has a reduced risk of corneal infection.
引用
收藏
页码:1087 / 1093
页数:7
相关论文
共 33 条
[21]   Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations [J].
Holladay, JT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09) :1356-1370
[22]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24
[23]   MICRON-RESOLUTION RANGING OF CORNEA ANTERIOR-CHAMBER BY OPTICAL REFLECTOMETRY [J].
HUANG, D ;
WANG, JP ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
LASERS IN SURGERY AND MEDICINE, 1991, 11 (05) :419-425
[24]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[25]   AXIAL LENGTH FOLLOWING IMPLANTATION OF POSTERIOR CHAMBER LENSES [J].
NAESER, K ;
NAESER, A ;
BOBERGANS, J ;
BARGUM, R .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (06) :673-675
[26]   SOURCES OF ERROR IN INTRAOCULAR-LENS POWER CALCULATION [J].
OLSEN, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (02) :125-129
[27]  
OLSEN T, 1989, ACTA OPHTHALMOL, V67, P141
[28]  
PULIAFITO CA, 1995, OPHTHALMOLOGY, V102, P217
[29]   DEVELOPMENT OF THE SRK/T INTRAOCULAR-LENS IMPLANT POWER CALCULATION FORMULA [J].
RETZLAFF, JA ;
SANDERS, DR ;
KRAFF, MC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03) :333-340
[30]  
SANDERS D, 1981, AM INTRAOCULAR IMPLA, V7, P337