Effect of new innovative restorative carbomised glass cement on intrapulpal temperature rise: an ex-vivo study

被引:8
作者
Botsali, Murat Selim [1 ]
Tokay, Ugur [2 ]
Ozmen, Bilal [3 ]
Cortcu, Murat [3 ]
Koyuturk, Alp Erdin [3 ]
Kahvecioglu, Firdevs [1 ]
机构
[1] Selcuk Univ, Sch Dent, Dept Pediat Dent, Konya, Turkey
[2] Zirve Univ, Sch Dent, Dept Pediat Dent, Gaziantep, Turkey
[3] Ondokuz Mayis Univ, Sch Dent, Dept Pediat Dent, Samsun, Turkey
关键词
Glass Ionomer Cements; Composite Resins; Dentin; Curing Lights; Dental; LIGHT-CURING UNITS; PULP CHAMBER; IN-VITRO; COMPOSITE; POLYMERIZATION; INCREASE; LASER; ADHESIVE; HALOGEN;
D O I
10.1590/1807-3107BOR-2016.vol30.0067
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to evaluate the temperature changes that occurred in the pulp chamber when using GCP Glass Carbomer Fill (GCP) and two different resin-modified glass-ionomer (RGI) restorative materials at different dentin thicknesses. A standardized Class I occlusal cavity with 1 mm or 2 mm dentin thickness was prepared in the extracted human molar teeth. RGI and GCP fills were placed in the cavities and cured with two different light-curing units. This study included a total of 120 samples, with 20 samples in each group. The pulp microcirculation method was used for measuring the intrapulpal temperature changes. Statistical analysis was performed using the two-way ANOVA and Tukey HSD multiple comparison tests. Statistically significant differences were observed between 1 mm and 2 mm dentin thicknesses (p < 0.001). The GCP groups (both 1 mm and 2 mm dentin thicknesses) exhibited higher temperatures than the other groups (p < 0.001), and Fuji II LC and Photac Fil Quick Aplicap showed similar values (p > 0.05). The highest temperature changes were observed with 1 mm dentin thickness. While RGI materials in both dentin thicknesses did not cause temperature changes that were harmful to the pulp, GCP CarboLED LCU caused the highest intrapulpal temperature rise, and these values were borderline harmful to the dental pulp.
引用
收藏
页数:7
相关论文
共 28 条
[11]   Compressive strength of two newly developed glass-ionomer materials for use with the Atraumatic Restorative Treatment (ART) approach in class II cavities [J].
Koenraads, H. ;
Van der Kroon, G. ;
Frencken, J. E. .
DENTAL MATERIALS, 2009, 25 (04) :551-556
[12]  
Lieu C, 2001, J Can Dent Assoc, V67, P36
[13]  
Matalon S, 2010, AM J DENT, V23, P223
[14]  
Michalakis K, 2006, J PROSTHET DENT, V96, P418, DOI 10.1016/j.prosdent.2006.10.005
[15]  
Mjor IA, 2002, QUINTESSENCE INT, V33, P35
[16]   Remaining dentine thickness and human pulp responses [J].
Murray, PE ;
Smith, AJ ;
Windsor, LJ ;
Mjör, IA .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (01) :33-43
[17]   In vitro assessment of temperature change in the pulp chamber during cavity preparation [J].
Öztürk, B ;
Üsümez, A ;
Öztürk, AN ;
Ozer, F .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (05) :436-440
[18]  
Ozturk B, 2004, OPER DENT, V29, P325
[19]   Temperature rise caused in the pulp chamber under simulated intrapulpal microcirculation with different light-curing modes [J].
Ramoglu, Sabri Ilhan ;
Karamehmetoglu, Hilal ;
Sari, Tugrul ;
Usumez, Serdar .
ANGLE ORTHODONTIST, 2015, 85 (03) :381-385
[20]   Temperature rise in pulp and gel during laser-activated bleaching: in vitro [J].
Sari, Tugrul ;
Celik, Gozde ;
Usumez, Aslihan .