Examination of nanoparticles as a drug carrier on blood flow through catheterized composite stenosed artery with permeable walls

被引:46
|
作者
Ijaz, S. [1 ]
Nadeem, S. [1 ]
机构
[1] Quaid I Azam Univ, Dept Math, Islamabad 44000, Pakistan
关键词
Permeable walls; Blood flow; Composite stenosis; Exact solution; Copper nanoparticles; HEAT-TRANSFER; MAGNETIC-FIELD; METALLIC NANOPARTICLES; PERISTALTIC FLOW; NANOFLUID FLOW; FLUID-FLOW; SUSPENSION; ENCLOSURE;
D O I
10.1016/j.cmpb.2016.05.004
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this paper, we have discussed the influence of copper nanoparticles on a blood flow through composite stenosed artery with permeable walls. The nature of blood is discussed mathematically by considering it as viscous nanofluid. The study is carried out for a blood vessel under mild stenosis approximations and expressions of the temperature, velocity, resistance impedance to flow, wall shear stress and the pressure gradient is obtained by using corresponding boundary conditions. Results for the effects of permeability on blood flow through composite stenosis have been discussed graphically. The considered analysis also summarizes that the drug copper nanoparticles are efficient to reduce hemodynamics of stenosis and could be helpful to predict important uses for biomedical applications. Results indicate that nanoparticles are helpful as drug carriers to minimize the effects of resistance impedance to blood flow or coagulation factors due to stenosis. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:83 / 94
页数:12
相关论文
共 50 条
  • [21] Nanoparticles analysis on the blood flow through a tapered catheterized elastic artery with overlapping stenosis
    Nadeem, S.
    Ijaz, S.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2014, 129 (11):
  • [22] A SUSPENSION MODEL FOR BLOOD FLOW THROUGH A CATHETERIZED ARTERY
    Mishra, Shailesh
    Verma, Narendra Kumar
    Siddiqui, S. U.
    INTERNATIONAL JOURNAL OF BIOMATHEMATICS, 2012, 5 (05)
  • [23] MHD Micropolar Blood Flow Model through a Multiple Stenosed Artery
    Alnussairy, Esam A.
    Bakheet, Ahmed
    THIRD INTERNATIONAL CONFERENCE OF MATHEMATICAL SCIENCES (ICMS 2019), 2019, 2183
  • [24] Blood Flow through a Composite Stenosis in an Artery with Permeable Wall
    Mishra, Shailesh
    Siddiqui, S. U.
    Medhavi, Amit
    APPLICATIONS AND APPLIED MATHEMATICS-AN INTERNATIONAL JOURNAL, 2011, 6 (01): : 58 - 73
  • [25] Unsteady non-Newtonian blood flow through a tapered overlapping stenosed catheterized vessel
    Ali, N.
    Zaman, A.
    Sajid, M.
    Nieto, J. J.
    Torres, A.
    MATHEMATICAL BIOSCIENCES, 2015, 269 : 94 - 103
  • [26] A significant role of permeability on blood flow for hybrid nanofluid through bifurcated stenosed artery: Drug delivery application
    Shahzadi, Iqra
    Bilal, S.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 187
  • [27] Entropy Generation Analysis in Convective Ferromagnetic Nano Blood Flow Through a Composite Stenosed Arteries with Permeable Wall
    Noreen Sher Akbar
    Adil Wahid Butt
    CommunicationsinTheoreticalPhysics, 2017, 67 (05) : 554 - 560
  • [28] Effects of Tapering and Electro-Osmosis on Copper-Suspended Nanofluid Through a Composite Stenosed Artery with Permeable Walls: Exact Solutions
    Zeeshan, Ahmed
    Riaz, Arshad
    Javaid, Asfand
    Nawaz, Tayyab
    Akram, Safia
    BRAZILIAN JOURNAL OF PHYSICS, 2024, 54 (05)
  • [29] Numerical Simulation of Blood Flow Dynamics in a Stenosed Artery Enhanced by Copper and Alumina Nanoparticles
    Zuberi, Haris Alam
    Lal, Madan
    Singh, Amol
    Zainal, Nurul Amira
    Chamkha, Ali J.
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2025, 142 (02): : 1839 - 1864
  • [30] A Balloon Model Examination with Impulsion of Cu-Nanoparticles as Drug Agent through Stenosed Tapered Elastic Artery
    Ijaz, S.
    Nadeem, S.
    JOURNAL OF APPLIED FLUID MECHANICS, 2017, 10 (06) : 1773 - 1783