CFD analysis on bioliquid co-firing with heavy fuel oil in a 400 MWe power plant with a wall-firing boiler

被引:16
|
作者
Park, Jong Keun [1 ]
Park, Sangbin [1 ,2 ]
Ryu, Changkook [1 ]
Baek, Se Hyun [2 ]
Kim, Young Ju [2 ]
Park, Ho Young [2 ]
机构
[1] Sungkyunkwan Univ, Sch Mech Engn, Suwon 16419, South Korea
[2] KEPCO Res Inst, Clean Power Generat Lab, Daejeon 34056, South Korea
关键词
Bioliquid; Boiler; Co-firing; Computational fluid dynamics; Heavy fuel oil; Palm oil residue; GLYCEROL COMBUSTION; VEGETABLE-OILS; BIO-OILS; EMISSIONS; BIODIESEL; BIOMASS; BLENDS;
D O I
10.1016/j.applthermaleng.2017.06.104
中图分类号
O414.1 [热力学];
学科分类号
摘要
Liquid biomass derived from food processing, biodiesel production, or fast pyrolysis has good potential for use as fuel to displace diesel or heavy fuel oil (HFO) for heat and power, and a major demonstration was successfully conducted in a 400 MWe HFO-fired power plant with a wall-firing boiler configuration using a BL blend of palm oil, its residue, and animal fat at a 20% co-firing ratio. When compared to a condition with HFO as fuel, the heat transfer rate on the membrane wall significantly decreased, and that of the convective heat exchangers in the upper furnace increased. This trend was different from what was observed at two smaller plants of 100 and 75 MWe, both with a tangential-firing boiler. This study uses computational fluid dynamics (CFD) to investigate the reason for the difference in the heat transfer characteristics. In both boiler types, bioliquid (BL) combustion led to lower soot concentrations and a corresponding decrease in radiation. This directly reduced the heat absorption on the furnace wall by approximately 5% at 20%-BL co-firing in the wall-firing boiler, and it was predicted further decrease linearly by 14% at 100%-BL firing. However, the tangential-firing boilers had less than a 1% decrease in measured heat absorption on the furnace wall at 100%-BL firing. Such differences were attributable to the gas flow pattern of the two boiler configurations. The burner tilting and flue gas recirculation of the tangential-firing boilers also contributed to successful operation at 100%-BL firing. The conclusions indicate that without effective measures to control the heat absorption distribution, the capability of a wall-firing boiler for BL combustion is limited to low co-firing ratios. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1247 / 1256
页数:10
相关论文
共 50 条
  • [1] Damper opening optimization and performance of a co-firing boiler in a 300 MWe plant
    Chen, Hongwei
    Liang, Zhanwei
    APPLIED THERMAL ENGINEERING, 2017, 123 : 865 - 873
  • [2] Optimizing a woodchip and coal co-firing retrofit for a power utility boiler using CFD
    Gao, Haining
    Runstedtler, Allan
    Majeski, Adrian
    Boisvert, Patrick
    Campbell, Doug
    BIOMASS & BIOENERGY, 2016, 88 : 35 - 42
  • [3] Numerical study of co-firing coal and Cynara cardunculus in a 350 MWe utility boiler
    Pallares, Javier
    Gil, Antonia
    Cortes, Cristobal
    Herce, Carlos
    FUEL PROCESSING TECHNOLOGY, 2009, 90 (10) : 1207 - 1213
  • [4] Co-firing straw and coal in a 150-MWe utility boiler:: in situ measurements
    Hansen, PFB
    Andersen, KH
    Wieck-Hansen, K
    Overgaard, P
    Rasmussen, I
    Frandsen, FJ
    Hansen, LA
    Dam-Johansen, K
    FUEL PROCESSING TECHNOLOGY, 1998, 54 (1-3) : 207 - 225
  • [5] CFD analysis of the effects of co-firing biomass with coal
    Ghenai, Chaouki
    Janajreh, Isam
    ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (08) : 1694 - 1701
  • [6] Biomass co-firing and refuse derived fuel fired boiler considerations
    Harvey, A. L.
    Harvey, R. McA
    APPITA, 2015, 68 (03): : 201 - 206
  • [7] Numerical modelling of the co-firing of pulverised coal and straw in a 300 MWe tangentially fired boiler
    Gubba, S. R.
    Ingham, D. B.
    Larsen, K. J.
    Ma, L.
    Pourkashanian, M.
    Tan, H. Z.
    Williams, A.
    Zhou, H.
    FUEL PROCESSING TECHNOLOGY, 2012, 104 : 181 - 188
  • [8] Process simulation of co-firing torrefied biomass in a 220 MWe coal-fired power plant
    Li, Jun
    Zhang, Xiaolei
    Pawlak-Kruczek, Halina
    Yang, Weihong
    Kruczek, Pawel
    Wasiak, Wlodzimierz
    ENERGY CONVERSION AND MANAGEMENT, 2014, 84 : 503 - 511
  • [9] COMPUTATIONAL ANALYSIS OF PULVERIZED COAL CO-FIRING WITH BIOMASS IN 150MWe UNIT OF TUNCBILEK THERMAL POWER PLANT
    Deniz Canal, Cansu
    Boke, Yakup Erhan
    Aydin, Ozer
    Benim, Ali Cemal
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2021, 41 (01) : 37 - 50
  • [10] Feasibility Analysis of Co-firing Discard-oil for Power Generation
    Wang, Ping
    Zhou, HuiBo
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1477 - 1480