Performance Evaluation of the LabPET12, a Large Axial FOV APD-based Digital PET Scanner

被引:10
作者
Bergeron, M. [1 ]
Cadorette, J. [2 ]
Bureau-Oxton, C. [3 ]
Beaudoin, J. -F. [2 ]
Tetrault, M. -A. [5 ]
Leroux, J. -D. [5 ]
Lepage, M. D. [4 ]
Robert, G. [4 ]
Fontaine, R. [5 ]
Lecomte, R. [1 ,2 ]
机构
[1] Univ Sherbrooke, Dept Med Nucl & Radiobiol, Sherbrooke, PQ J1K 2R1, Canada
[2] CHUS, Sherbrooke Mol Imaging Ctr, Sherbrooke, PQ, Canada
[3] Univ Sherbrooke, Dept Phys, Sherbrooke, PQ, Canada
[4] Gamma Medica Ideas, Sherbrooke, PQ, Canada
[5] Univ Sherbrooke, Dept Elect & Comp Engn, Sherbrooke, PQ, Canada
来源
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2009年
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Avalanche photodiodes; Performance evaluation; PET instrumentation; Positron emission tomography; ARCHITECTURE; SENSITIVITY; RESOLUTION;
D O I
10.1109/NSSMIC.2009.5401915
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The LabPET12 is the latest version of LabPET (TM) avalanche photodiode (APD)-based digital scanners, having an 11.4 cm axial field of view and 9216/4608 crystals/electronic readout channels to achieve high sensitivity and count rate performance, while preserving the same very high spatial resolution. Its performance characteristics have been thoroughly investigated largely based on the new NEMA NU4 - 2008 small animal PET standard. Average energy resolution is 20 +/- 3% for LYSO and 19 +/- 3% for LGSO. After timing alignment, the overall FWHM timing resolution is 7.1/8.3/9.2 ns for LYSO/LYSO, mixed and LGSO/LGSO coincidences. Imaging performance was assessed using various energy windows with lower threshold from 100 to 350 keV. Sensitivity varied from 8 to 2.8%, between 100 and 350 keV. With the lower threshold set at 200 keV, peak NEC count rates were 449 kcps at 66 MBq and 179 kcps at 81 MBq for the mouse and rat NEMA phantoms, respectively. Two acquisition modes were investigated, a high sensitivity and high resolution mode. Whole-body static images of mice were obtained with (NaF)-F-18. In conclusion, the LabPET12 provides excellent dynamic performance with shorter imaging time or lower injected radioactivity while achieving the same exquisite spatial resolution as the LabPET4 and LabPET8 scanners.
引用
收藏
页码:4017 / +
页数:2
相关论文
共 13 条
  • [1] [Anonymous], 2008, NEMA STAND PUBL
  • [2] Performance Evaluation of the Inveon Dedicated PET Preclinical Tomograph Based on the NEMA NU-4 Standards
    Bao, Qinan
    Newport, Danny
    Chen, Mu
    Stout, David B.
    Chatziioannou, Arion F.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (03) : 401 - 408
  • [3] Beaudoin J.-F., 2008, 2008 IEEE Nuclear Science Symposium Conference Record, P3841
  • [4] Performance Evaluation of the LabPET APD-Based Digital PET Scanner
    Bergeron, Melanie
    Cadorette, Jules
    Beaudoin, Jean-Francois
    Lepage, Martin D.
    Robert, Ghislain
    Selivanov, Vitali
    Tetrault, Marc-Andre
    Viscogliosi, Nicolas
    Norenberg, Jeffrey P.
    Fontaine, Rejean
    Lecomte, Roger
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 10 - 16
  • [5] A handy time alignment probe for timing calibration of PET scanners
    Bergeron, Melanie
    Pepin, Catherine M.
    Arpin, Louis
    Leroux, Jean-Daniel
    Tetrault, Marc-Andre
    Viscogliosi, Nicolas
    Fontaine, Rejean
    Lecomte, Roger
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 599 (01) : 113 - 117
  • [6] The Hardware and Signal Processing Architecture of LabPET™, a Small Animal APD-Based Digital PET Scanner
    Fontaine, Rejean
    Belanger, Francois
    Viscogliosi, Nicolas
    Semmaoui, Hicham
    Tetrault, Marc-Andre
    Michaud, Jean-Baptiste
    Pepin, Catherine
    Cadorette, Jules
    Lecomte, Roger
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 3 - 9
  • [7] Performance evaluation of the Philips MOSAIC small animal PET scanner
    Huisman, Marc C.
    Reder, Sybille
    Weber, Axel W.
    Ziegler, Sibylle I.
    Schwaiger, Markus
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (04) : 532 - 540
  • [8] Performance of the Fourier rebinning algorithm for PET with large acceptance angles
    Matej, S
    Karp, JS
    Lewitt, RM
    Becher, AJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) : 787 - 795
  • [9] Performance evaluation of a high-sensitivity large-aperture small-animal PET scanner: ClairvivoPET
    Mizuta, Tetsuro
    Kitamura, Keishi
    Iwata, Hiroshi
    Yamagishi, Yoshiyuki
    Ohtani, Atsushi
    Tanaka, Kazumi
    Inoue, Yoshihiro
    [J]. ANNALS OF NUCLEAR MEDICINE, 2008, 22 (05) : 447 - 455
  • [10] Detector response models for statistical iterative image reconstruction in high resolution PET
    Selivanov, VV
    Picard, Y
    Cadorette, J
    Rodrigue, S
    Lecomte, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1168 - 1175