Nickel-based electrochemical sensor with a wide detection range for measuring hydroxyl ions and pH sensing

被引:10
作者
Jafari, Behnaz [1 ]
Muthuvel, Madhivanan [2 ]
Botte, Gerardine G. [1 ]
机构
[1] Texas Tech Univ, Dept Chem Engn, Chem & Electrochem Technol & Innovat Lab, Lubbock, TX 79401 USA
[2] Ohio Univ, Ctr Electrochem Engn Res, Dept Chem & Biomol Engn, Athens, OH 45701 USA
基金
比尔及梅琳达.盖茨基金会;
关键词
Hydroxyl ions detection; pH sensor; Nickel oxyhydroxide; Water quality; Electrochemical sensors; IN-SITU; ALKALINE-SOLUTION; OPTICAL SENSOR; THIN-FILM; ELECTRODES; OXIDATION; UREA;
D O I
10.1016/j.jelechem.2021.115547
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The importance of hydroxyl ions concentration measurement in solution necessitates the development of suitable and simple sensing methods for online detection. To address this need, an electrochemical sensor was developed using nickel as the working electrode that enabled specificity towards hydroxyl ions and their successfully quantification. The electrochemical reaction between nickel and hydroxyl ions in solution generates a current which is proportional to the concentration of hydroxyl ions and consequently is also correlated to the pH of the solution. Cyclic voltammetry and chronoamperometry techniques were used to prepare and activate the nickel electrode for detection. The analysis of chronoamperometric experiments in different solutions exhibited three calibration curves between the current and hydroxyl ion concentrations for three regions in the range of 0.3 mu M to 4.8 M with a short response time of 14 s. Up to now, no other hydroxyl ion sensor has been reported that can reach this detection limit. This sensor also holds promise to work perfectly in highly alkaline environments where only costly commercial electrodes are available to quantify pH. The results show three linear calibration curves between the current and pH of the solution over the pH range of 7.4 to 14.6. In addition to the wide detection range, the sensor exhibits a relative standard deviation percentage lower than 7% over 9 months of experiments, confirming repeatability of measurements and stability of the electrode. The potential of the proposed method to measure pH in real applications was demonstrated by testing the sensor in solutions containing urea, nitrates, phosphates, and sulfates.
引用
收藏
页数:8
相关论文
共 20 条
[1]   Highly Selective Detection of H+ and OH- with a Single-Emissive Iridium(III) Complex: A Mild Approach to Conversion of Non-AIEE to AIEE Complex [J].
Alam, Parvej ;
Kaur, Gurpreet ;
Sarmah, Amrit ;
Roy, Ram Kinkar ;
Choudhury, Angshuman Roy ;
Laskar, Inamur Rahaman .
ORGANOMETALLICS, 2015, 34 (18) :4480-4490
[2]  
Bates R.G., 1973, J ELECTROCHEM SOC, V120, p263C, DOI DOI 10.1149/1.2403829
[3]   THE ANODIC LAYER ON NICKEL IN ALKALINE-SOLUTION - AN INVESTIGATION USING INSITU IR SPECTROSCOPY [J].
BEDEN, B ;
BEWICK, A .
ELECTROCHIMICA ACTA, 1988, 33 (11) :1695-1698
[4]   Urea electrolysis: direct hydrogen production from urine [J].
Boggs, Bryan K. ;
King, Rebecca L. ;
Botte, Gerardine G. .
CHEMICAL COMMUNICATIONS, 2009, (32) :4859-4861
[5]  
Federation, 1915, STANDARD METHODS EXA, V2
[6]   Electrochemical determination of sulphide at nickel electrodes in alkaline media: a new electrochemical sensor [J].
Giovanelli, D ;
Lawrence, NS ;
Jiang, L ;
Jones, TGJ ;
Compton, RG .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (03) :320-328
[7]   Development of the Glass Electrode and the pH Response [J].
Graham, Daniel J. ;
Jaselskis, Bruno ;
Moore, Carl E. .
JOURNAL OF CHEMICAL EDUCATION, 2013, 90 (03) :345-351
[8]   INSITU UV VISIBLE REFLECTANCE SPECTROSCOPIC INVESTIGATION OF THE NICKEL ELECTRODE ALKALINE-SOLUTION INTERFACE [J].
HAHN, F ;
BEDEN, B ;
CROISSANT, MJ ;
LAMY, C .
ELECTROCHIMICA ACTA, 1986, 31 (03) :335-342
[9]   Nickel oxide screen printed electrodes for the sensing of hydroxide ions in aqueous solutions [J].
Hallam, Philip M. ;
Kampouris, Dimitrios K. ;
Kadara, Rashid O. ;
Jenkinson, Norman ;
Banks, Craig E. .
ANALYTICAL METHODS, 2010, 2 (08) :1152-1155
[10]   Flexible pH sensors based on printed nanocomposites of single-wall carbon nanotubes and Nafion [J].
Jeon, Jun-Young ;
Kang, Byeong-Cheol ;
Ha, Tae-Jun .
APPLIED SURFACE SCIENCE, 2020, 514