An Improved Method for Estimating in Situ Sampling Rates of Nonpolar Passive Samplers

被引:179
作者
Booij, Kees [1 ]
Smedes, Foppe [2 ]
机构
[1] Royal Netherlands Inst Sea Res, NL-1790 AB Texel, Netherlands
[2] Deltares, NL-3508 AL Utrecht, Netherlands
关键词
SEMIPERMEABLE-MEMBRANE DEVICES; PERSISTENT ORGANIC POLLUTANTS; AIR SAMPLERS; CALIBRATION;
D O I
10.1021/es101321v
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The quality of passive sampling methods for measuring concentrations of dissolved hydrophobic contaminants relies on accurate knowledge of in situ sampling rates. In currently used methods for estimating these sampling rates from the dissipation rates of performance reference compounds (PRCs), the PRCs that show either insignificant or complete dissipation are ignored. We explored the merits of nonlinear least-squares (NLS) methods for estimating sampling rates, aiming to retain the information stored in PRC data that is neglected in the traditional methods. To this end, we examined the error structure of weighted NLS, unweighted NLS, and the traditional methods, using model simulations. The results show that sampling rates are best estimated using unweighted NLS. Uncertainties in the sampler-water partition coefficients may result in biased estimates that only weakly depend on the number of PRCs being used. The major advantage of unweighted NLS over the traditional method is that sampling rate estimates and uncertainties are available where the traditional method fails, and that the variability of sampling rate estimates is smaller.
引用
收藏
页码:6789 / 6794
页数:6
相关论文
共 28 条
[11]  
Huckins J.N., 2006, Monitors of Organic Chemicals in the Environment: Semipermeable Membrane Devices
[12]   Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices [J].
Huckins, JN ;
Petty, JD ;
Lebo, JA ;
Almeida, FV ;
Booij, K ;
Alvarez, DA ;
Clark, RC ;
Mogensen, BB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (01) :85-91
[13]  
KINGSTON JK, 2000, THESIS U PORTSMOUTH
[14]   Dynamic permeation method to determine partition coefficients of highly hydrophobic chemicals between poly(dimethylsiloxane) and water [J].
Kwon, Jung-Hwan ;
Wuethrich, Thomas ;
Mayer, Philipp ;
Escher, Beate I. .
ANALYTICAL CHEMISTRY, 2007, 79 (17) :6816-6822
[15]   Global Aquatic Passive Sampling (AQUA-GAPS): Using Passive Samplers to Monitor POPs in the Waters of the World [J].
Lohmann, Rainer ;
Muir, Derek .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (03) :860-864
[16]   Determination of kinetic and equilibrium regimes in the operation of polar organic chemical integrative samplers - Application to the passive sampling of the polar herbicides in aquatic environments [J].
Mazzella, Nicolas ;
Dubernet, Jean-Francois ;
Delmas, Francois .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) :42-51
[17]  
Pournelle G. H., 1953, Journal of Mammalogy, V34, P133, DOI 10.1890/0012-9658(2002)083[1421:SDEOLC]2.0.CO
[18]  
2
[19]   Toward a global network for persistent organic pollutants in air: Results from the GAPS study [J].
Pozo, Karla ;
Harner, Tom ;
Wania, Frank ;
Muir, Derek C. G. ;
Jones, Kevin C. ;
Barrie, Leonard A. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (16) :4867-4873
[20]   Calibration of Silicone Rubber Passive Samplers: Experimental and Modeled Relations between Sampling Rate and Compound Properties [J].
Rusina, Tatsiana P. ;
Smedes, Foppe ;
Koblizkova, Martina ;
Klanova, Jana .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (01) :362-367