In-line analysis of ground beef using a diode array near infrared instrument on a conveyor belt

被引:16
作者
Hildrum, KI
Nilson, BN
Westad, F
Wahlgren, NM
机构
[1] MATFORSK, N-1430 As, Norway
[2] Norway Meat, N-0513 Oslo, Norway
关键词
near infrared spectroscopy (NIR); beef; in-line analysis; conveyer belt;
D O I
10.1255/jnirs.445
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In-line monitoring of the proximal composition of ground beef on a conveyer belt has been tested using a near infrared (NIR) reflectance instrument with a diode array detector. Sixty batches of coarsely ground beef were processed under industry conditions and monitored continuously. After removing signals originating from the belt itself, the remaining data were used to make partial least squares models for all samples at two different grinding sizes. The correlation coefficients were in the range 0.93-0.96, while the full cross-validated errors for fat and water were between 1.6 and 2.4%. The corresponding errors for protein were 0.5-0.8%. A forward variable selection method based on jack-knifing yielded similar results. The predictions were generally best for the smallest grinding size. The loading plots showed that there was a high interdependency between calibrations for the different components. Before implementation of the calibrations, they must be re-tested under industry conditions on new independent batches.
引用
收藏
页码:367 / 376
页数:10
相关论文
共 20 条
[1]  
ANDERSON NM, 2003, T ASAE, V46
[2]  
BORGGAARD C, 2003, P 49 ICOMST BRAS
[3]  
*BUCH LAB GMBH, 1997, 4 AOAC BUCH LAB GMBH
[4]  
DAVIES T, 1996, SPECTROSCOPY EUROPE, V8, P368
[5]  
DOWNEY G, 2004, AGRONOMY MONOGRAPH, V44, P599
[6]   On attempts to measure the tenderness of Longissimus Dorsi muscles using fluorescence emission spectra [J].
Egelandsdal, B ;
Wold, JP ;
Sponnich, A ;
Neegård, S ;
Hildrum, KI .
MEAT SCIENCE, 2002, 60 (02) :187-202
[7]   Batch accuracy of on-line fat determination [J].
Hansen, PW ;
Tholl, I ;
Christensen, C ;
Jehg, HC ;
Borg, J ;
Nielsen, O ;
Ostergaard, B ;
Nygaard, J ;
Andersen, O .
MEAT SCIENCE, 2003, 64 (02) :141-147
[8]  
HILDRUM KI, 1995, MEAT FOCUS INT, V4, P156
[9]  
HILDRUM KI, 2003, 12 INT C NIR SPECTR
[10]  
*INOT, 2003, 103 IN