Micromorphometrical analysis of conventional osteotomy techniques and ultrasonic osteotomy at the rabbit skull

被引:52
作者
Maurer, Peter [1 ]
Kriwalsky, Marcus S. [1 ]
Veras, Rafael Block [1 ]
Vogel, Juergen [2 ]
Syrowatka, Frank [3 ]
Heiss, Christian [4 ]
机构
[1] Univ Halle Wittenberg, Dept Oral & Plast Maxillofacial Surg, D-06097 Halle, Germany
[2] Univ Halle Wittenberg, Inst Bioengn, Dept Engn, D-06097 Halle, Germany
[3] Univ Halle Wittenberg, Ctr Mat Sci, D-06097 Halle, Germany
[4] Univ Giessen Marburg, Dept Trauma Surg, Lab Expt Trauma Surg, Marburg, Germany
关键词
confocal laser scanning microscopy; environmental scanning electron microscopy; morphological analysis; osteotomy; ultrasonic osteotome;
D O I
10.1111/j.1600-0501.2007.01516.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The ultrasonic osteotome, which was recently introduced, is an alternative to conventional methods of osteotomy. The aim of the present study was to establish the differences between three osteotomy techniques and to perform a quantitative roughness analysis of the osteotomized bone surfaces. Materials and methods: Fresh bony samples of standardized size were taken from the rabbit skull. The techniques used were as follows: reciprocate micro-saw, Lindemann bur, ultrasonic osteotome with the two insert tips OT6 (rough) and OT7 (fine). The prepared surfaces were examined by light microscopy, environmental surface electron microscopy (ESEM) and by confocal laser scanning microscopy (CLSM). Results: It was difficult to distinguish between cortical and cancellous bone after using the conventional osteotomy technique. The ultrasonic technique preserved the original structure of the bone. The values observed for superficial roughness were as follows: 3.97 mu m (micro-saw), 5.7 mu m (Lindemann bur), 2.48 mu m (OT7) and 3 mu m (OT6). There were statistical differences between the values of the bur and insert tip OT6 (P=0.015) as well as between the bur and insert tip OT7 (P=0.003). Conclusions: In the present study micromorphological differences after using various osteotomy techniques could be clearly identified.
引用
收藏
页码:570 / 575
页数:6
相关论文
共 50 条
[21]   Comparison of Piezosurgery and Conventional Osteotomy for Orbital Hypertelorism Surgical Correction [J].
Liu, Xiangqi ;
Zhang, Ziwei ;
Kim, Byeong Seop ;
Lin, Li ;
Han, Wenqin ;
Chai, Gang ;
Xu, Haisong ;
Yang, Xianxian .
JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (02) :817-819
[22]   The comparison of edema and ecchymosis after piezoelectric and conventional osteotomy in rhinoplasty [J].
Ümit Taşkın ;
Timur Batmaz ;
Mehmet Erdil ;
Salih Aydın ;
Kadir Yücebaş .
European Archives of Oto-Rhino-Laryngology, 2017, 274 :861-865
[23]   Postoperative neurosensory impairment perception using ultrasonic BoneScalpel and conventional rotary instruments after bilateral split sagittal osteotomy [J].
Carlos Alberto Ruiz Valero ;
Andrés Gómez-Delgado ;
Natalia Henao-Moreno .
Oral and Maxillofacial Surgery, 2021, 25 :495-508
[24]   The comparison of edema and ecchymosis after piezoelectric and conventional osteotomy in rhinoplasty [J].
Taskin, Umit ;
Batmaz, Timur ;
Erdil, Mehmet ;
Aydin, Salih ;
Yucebas, Kadir .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (02) :861-865
[25]   Postoperative neurosensory impairment perception using ultrasonic BoneScalpel and conventional rotary instruments after bilateral split sagittal osteotomy [J].
Ruiz Valero, Carlos Alberto ;
Gomez-Delgado, Andres ;
Henao-Moreno, Natalia .
ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2021, 25 (04) :495-508
[26]   Craneomaxillofacial osteotomy with ultrasonic system. Treatment option and initial experience [J].
Olate M., Sergio ;
Almeida A., Andres ;
Unibazo Z., Alejandro ;
Alister H., Juan Pablo ;
Uribe F., Francisca ;
Martinez V., Felipe ;
Huentequeo-Molina, Claudio .
REVISTA CHILENA DE CIRUGIA, 2013, 65 (05) :454-462
[27]   Osseodensification: An Alternative to Conventional Osteotomy in Implant Site Preparation: A Systematic Review [J].
Pereira, Joao Fontes ;
Costa, Rosana ;
Vasques, Miguel Nunes ;
Salazar, Filomena ;
Mendes, Jose Manuel ;
da Camara, Marco Infante .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (22)
[28]   Patterns of healing: a comparison of two proximal tibial osteotomy techniques [J].
Peek, Anna C. ;
Timms, Anna ;
Chin, Kuen F. ;
Calder, Peter ;
Goodier, David .
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2016, 11 (01) :59-62
[29]   Evaluation of facial aesthetics by laypersons in patients undergoing intraoral quadrangular Le Fort II osteotomy compared with conventional Le Fort I osteotomy [J].
Cede, J. ;
Graf, A. ;
Zeitlinger, J. ;
Wagner, F. ;
Willinger, K. ;
Klug, C. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (09) :1210-1218
[30]   Tissue changes and tissue reactivity following osteotomy by a conventional rotary device, an ultrasonic unit, and an Er: YAG laser - A comparative study in humans [J].
Blagova, Bistra ;
Krastev, Dimo ;
Krastev, Nikolay ;
Malinova, Lina .
JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2024, 125 (05)