Non-destructive, depth resolved investigation of corrosion layers of historical glass objects by 3D Micro X-ray fluorescence analysis

被引:45
作者
Kanngiesser, B. [1 ]
Mantouvalou, I. [1 ]
Malzer, W. [1 ]
Wolff, T. [1 ,2 ]
Hahn, O. [2 ]
机构
[1] Tech Univ Berlin, Inst Opt & Atom Phys, Berlin, Germany
[2] BAM Fed Inst Mat Res & Testing, Berlin, Germany
关键词
Glass;
D O I
10.1039/b717286a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
3D Micro X-ray fluorescence analysis was used for the investigation of reverse-glass paintings. The material-specific combination used in reverse-glass paintings leads to damage phenomena reinforced by glass corrosion. To elucidate the mechanism of corrosion processes taking place in the glass object depth profiles of mobile elements are of interest. In order to obtain elemental depth profiles of such kind of fragile objects the method of choice should be non-destructive. Our first results demonstrate the usefulness of the 3D Micro-XRF measurements for this kind of investigations. The assumption that certain binding media may initiate corrosion processes beginning at the interface glass/binding material could be confirmed.
引用
收藏
页码:814 / 819
页数:6
相关论文
共 16 条
[1]  
BERTZ S, 1999, FARBIGE KOSTBARKEITE, P181
[2]   The BESSY X-ray microfocus beamline project [J].
Erko, A ;
Schäfers, F ;
Firsov, A ;
Peatman, WB ;
Eberhardt, W ;
Signorato, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) :1543-1548
[3]  
FEKRSANATI F, 2001, STUD CONSERV, V46, P196
[4]   Three-dimensional micro-XRF investigations of paint layers with a tabletop setup [J].
Kanngiesser, B ;
Malzer, W ;
Rodriguez, AF ;
Reiche, I .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (01) :41-47
[5]   A new 3D micro X-ray fluorescence analysis set-up - First archaeometric applications [J].
Kanngiesser, B ;
Malzer, W ;
Reiche, I .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 211 (02) :259-264
[6]  
KOLLER J, 2003, WELCHE ZUWEILEN KUNS, P107
[7]   A model for the confocal volume of 3D micro X-ray fluorescence spectrometer [J].
Malzer, W ;
Kanngiesser, B .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (9-10) :1334-1341
[8]  
MANTOUVALOU I, IN PRESS ANAL CHEM
[9]   San Francisco Monastery, Quito, Equador: characterisation of building materials, damage assessment and conservation considerations [J].
Moropoulou, A ;
Polikreti, K ;
Ruf, V ;
Deodatis, G .
JOURNAL OF CULTURAL HERITAGE, 2003, 4 (02) :101-108
[10]  
Paschinger H., 1995, NATURWISSENSCHAFTEN, P63